background image

FIRE FRONTS & FRETS SUITABLE FOR THIS APPLIANCE.

The illustration shown is the recommended MACH II Front and Fret, if an alternate Front and Fret is used, it is
important to maintain the equivalent ventilation to that shown. Fronts and Frets are available under the following
part numbers: -

TYPE 

GC No 

CODE No 

TYPE 

GC No

CODE No

MACH 11 BLACK 

32 183 25

C022G 

JB BLACK 

32 183 38 

C019G

MACH 11 BRASS

32 183 48

C024G

63$5(6$1'6(59,&(

For spares and service, apply to your local Supplier, Installer or direct to the manufacturer, stating that the
appliance is a Super Hot Toaster quoting the GC Appliance Number and Serial Number from the data badge
located on the front controls panel.

Advantage should be taken of regular servicing and inspection for gas appliances to ensure their continued safe
operation.

6+2573$576/,67

Description

Crosslee No

GC No

Piezo Igniter

40245

397 686

Control Knob

40232

Control Valve

41833

Oxy-Pilot Burner Assembly

42313

170 415

Main Injector

41180

389 515

Coal Support

43010

Burner Inserts

42952

Front Simulated Coal

40481

Set of Coals

43011

Protective Side plates

41072

170 249

Maximum Heat Input (Gross)

6.95 kW 23700 Btu/h

Royal Cozyfires are manufactured by:

CROSSLEE plc

Aber Park Industrial Estate,

Aber Road, Flint, Flintshire. CH6 5EX

Spares Tel 01422 203963

Fax: 01422 204475

Service (GSA Ltd) 01703 516611

Customer Service 01422 200660

Fax 01422 206304

*Technical Help Line 0906 8633268

*Calls charged at 60p per minute

Содержание Super Hot Toater

Страница 1: ...SUPER HOT TOASTER USERS Pages 2 3 INSTALLATION Pages 4 7 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Страница 2: ...ritish Standards Institution BS 5258 Part 12 1990 and is for use on Natural Gas only All gas appliance installations must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the attached Installation Instructions failure to do so could lead to prosecution Areas of this appliance w...

Страница 3: ...e channel between the front and rear ports of burner Locate the fibre artificial coal front on the shelf above the fascia panel Figure 7 2 287 First Layer Position 4 large coals with their rear edge on the burner inserts Place 3 large coals at the rear of the coal support shelf and lay 2 further at the sides of the shelf These coals are placed on their edge 3 more large coals are placed on the coa...

Страница 4: ...The flue must be swept prior to installation unless new Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown on page 4 A hearth must always be provided to project forwards of the brass trim a minimum of...

Страница 5: ... rigid or semi rigid tube to a pressure test elbow situated on the left hand side of the burner as shown in Fig 1 It advisable to provide a means of isolating the gas supply to the appliance for servicing with either a restrictor elbow or isolation cock as shown in Fig 1 A 45mm length of Bundy is supplied for use with a restrictor elbow or a 90 degree bend for use with an isolation cock the supply...

Страница 6: ...ant reduction below an inlet pressure of 20mbar will indicate a restriction in the gas supply to the appliance that should be identified and corrected If there are any other appliances that are relatively high rated e g a central heating boiler fed from the same gas supply branch it is advisable to perform this observation with both appliances in operation 2 7 21 2 7 5 See figure 13 for identifica...

Страница 7: ...ault and rectify the cause The test should be repeated if an extractor fan is situated in the room or in any connecting room with all the doors in that room opened 9 Remove the Fret and push the flame adjustment lever inwards replace the Fret and check that the flame picture changes to a longer softer flame Demonstrate the lighting and extinguishing procedures to the user 9 6 7 7 The curing effect...

Страница 8: ...ont simulated coal To gain access to the components below the burner assembly it has to be removed from the Vent Box by disconnecting the gas supply at the inlet elbow and unscrewing the two screws at the base of the fascia panel Where the supply is fed from the right hand side across the front of the appliance it will be necessary to disconnect the supply from the isolation tap or restrictor elbo...

Страница 9: ...m the data badge located on the front controls panel Advantage should be taken of regular servicing and inspection for gas appliances to ensure their continued safe operation 6 257 3 576 67 Description Crosslee No GC No Piezo Igniter 40245 397 686 Control Knob 40232 Control Valve 41833 Oxy Pilot Burner Assembly 42313 170 415 Main Injector 41180 389 515 Coal Support 43010 Burner Inserts 42952 Front...

Страница 10: ......

Страница 11: ......

Страница 12: ...No Fig 6 issued with this document ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Отзывы: