![Roxell SparkCup Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/roxell/sparkcup/sparkcup_user-manual_1493853023.webp)
SPARKcup- USER’S GUIDE - EUG
ROXELL - 025 - 2416
17
PROBLEM
CAUSE
CORRECTIVE ACTION
10.
Birds perch on
the lines.
a.
No cable for poultry perch
guard is installed.
- Install cables for poultry perch guard or poultry
perch system when needed.
b.
Cable for poultry perch guard
is not electrified.
- Make a correct connection to the poultry perch
guard (turn on).
Check on short circuits.
c.
Cable for poultry perch guard
not stretched enough.
- Control by expert.
d.
Wrong connection between the
poultry perch guard and the
line.
- Use the correct high voltage cable.
e.
There is no earthing.
- Provide a correct earthing for the profile.
f.
Birds have got into the habit of
perching on the line.
- For breeders/layers : winch up the lines every
evening and/or encourage the birds to move
from the lines before switching off the lights.
11.
The line sags.
a.
Individual suspension points at
incorrect height.
- Suspend the line horizontally.
12.
Deformed sus-
pensions.
a.
Cable is stretched too much.
- Adjust the stretch on the cable.
b.
Birds perch on the line.
- See actions in case of birds perching on the
system.
13.
Line sags at the
pressure regulator.
a.
Incorrect height adjustment.
- Make sure that the pressure regulator is well
aligned with the rest of the line.
14.
Water pressure
on the line is too
high.
a.
Pressure regulator is still in the
”rinsing” position.
- Put in correct position.
b.
The pressure regulator is
defective.
- Replace or repair the pressure regulator.
15.
Suspension cord
loose.
a.
Incorrect fixing of the three
hole string adjuster / adjusting
plate.
- Install the three hole string adjuster clamp
correctly and check the other suspension
points.
16.
Insufficient wa-
ter supply in the
house.
a.
Water pressure is too low.
- Check the pump.
b.
Diameter of supply tube is too
small.
- Install supply pipes of at least 25 mm diameter.
17.
Difference
between incoming
and outgoing pres-
sure in the filter.
a.
Contamination of the filter set.
- Regularly replace the filter cartridge.
Use clear water.
18.
Insufficient wa-
ter consumption
when starting up
the layers (produc-
tion) at the age of
16-18 weeks.
a.
Birds have been reared on
another system.
b.
Not enough adaptation time.
- Longer period with light (24 hours).
- Maximum light intensity.
- Put some water into the cups.
- Lower the water pressure temporarily to 0,3
bar.