![Roxell SparkCup Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/roxell/sparkcup/sparkcup_user-manual_1493853016.webp)
ROXELL - 025 - 2416
SPARKcup-
USER'S GUIDE
- EUG
10
MANUAL FLUSHING (STANDARD)
Flushing button on pressure
regulator
Figure 1.
Each Sparkcup drinking line has a standard manual flushing system. This allows flushing the water pipes at random.
Procedure
:
1.
Open the end ball valve.
2.
Turn the flushing button in high position (complete ”flush”).
3.
The water is sent through the lines under full incoming pressure.
Ideal flushing :
an incoming pressure of 3 bar and a capacity of about 10 liters
per minute per line. Flush during 1 minute per 10 m line length.
4.
Set back the flushing button in the normal position.
5.
Shut off the end ball valve.
RESPECT THE PROCEDURE BELOW :
IF NOT, THE TOTAL SYSTEM IS UNNECESSARILY PUT UNDER
TOO HIGH PRESSURE WITH DAMAGE RISK !
Turn into flushing position
End ball valve
All lines can be flushed simultaneously when following the specifications for the right water supply.
With a low pressure water supply it is better to flush half of the lines or even line per line.
CAUTION