Roxell CoMeo Скачать руководство пользователя страница 119

ROXELL - 001 - 1020

COMEO - INSTALLATION INSTRUCTIONS

III- 63

MAXIMUM CABLE LENGTHS TO THE MOTORS

Calculation method:

IEC

­

HD 60364

­

5

Cable type:

PVC – XLPE – Silicon

Placing:

Open cable trough

Materials used:

Schneider Electric GV2 motor protections

Please be aware that you have to follow the local regulations for your country!

Motor Power (kW)

Net voltage

Protection

Max. cable length (m) Wire gauge (mm²)

0.12

3x230V 50Hz

GV2ME04

0 - 442

1.5

443 -736

2.5

737 - 1179

4

3x400V 50Hz

GV2ME03

0 - 1232

1.5

1233 - 2053

2.5

2054 - 3285

4

0.18

1x230V 50Hz

GV2ME07

0 - 110

1.5

111 - 185

2.5

186 - 297

4

3x230V 50Hz

GV2ME06

0 - 174

1.5

175 - 290

2.5

291 - 464

4

3x400V 50Hz

GV2ME05

0 - 492

1.5

493 - 821

2.5

822 - 1314

4

0.22

3x220V 60Hz

3x230V 60Hz

GV2ME06

0 - 167

1.5

168 - 279

2.5

280 - 446

4

3x380V 60Hz

3x400V 60Hz

GV2ME05

0 - 471

1.5

472 - 785

2.5

786 - 1257

4

0.25

1x230V 50Hz

GV2ME07

0 - 110

1.5

111 - 185

2.5

186 - 297

4

3x230V 50Hz

GV2ME06

0 - 174

1.5

175 - 290

2.5

291 - 464

4

3x400V 50Hz

GV2ME05

0 - 492

1.5

493 - 821

2.5

822 - 1314

4

0.37

1x230V 50Hz

GV2ME08

0 - 69

1.5

70 - 116

2.5

117 - 185

4

3x230V 50Hz

GV2ME07

0 - 111

1.5

112 - 185

2.5

186 - 297

4

3x400V 50Hz

GV2ME06

0 - 308

1.5

309 - 513

2.5

514 - 821

4

Содержание CoMeo

Страница 1: ...00107470 00107470 001 1020 CoMeo Use and Assembly Guide EN ENGLISH Original use and assembly guide ...

Страница 2: ...I 13 OPTION THUMPER KIT FOR DOUBLE INTAKE BOOT II 13 OPTION EXTENSION WITH SENSOR 230 V AC 24 V DC II 14 CONTROL UNIT COMEO WITH SWITCH II 15 CONTROL UNIT COMEO WITH SENSOR II 16 FIXED INTERMEDIATE CONTROL UNIT COMEO WITH SWITCH II 17 FIXED INTERMEDIATE CONTROL UNIT COMEO WITH SENSOR II 18 MOVABLE INTERM CONTR UN COMEO W SWITCH II 19 MOVABLE INTERM CONTR UN COMEO W SENSOR II 20 POWER UNIT II 21 PO...

Страница 3: ... FEEDER LINE III 33 TO INSTALL THE INTERMEDIATE CONTROL III 35 TO INSTALL THE TUBE WITH HOLE III 35 CONTROL PANEL INTERMEDIATE CONTROL UNIT WITH SENSOR III 36 FEED INTAKE BOOT III 37 OPTION SUPPORT FOR HOPPER IN LINE III 37 TO INSTALL AND SUSPEND THE 100KG HOPPER III 38 TO INSTALL THE CONTROL UNIT III 39 POWER UNIT SUSPENSION III 39 CONNECTION BOX KIT FOR CONTROL PAN FOR US ONLY III 40 TO INSTALL ...

Страница 4: ...ginal content Roxell disclaims responsibility for any and all damages injuries warranty claims and or anyother claimsassociatedwithsuchchanges inasmuch assuchchangesresult incontent thatis differentfrom theauthoritat ive Roxell published English version of the manual For current product installation and operation information please con tact the customer service and or technical service departments...

Страница 5: ...ing agents and disinfectants in violation with the instructions received from the suppliers or use of the Products in an ATEX surrounding The Extended Warranty shall not apply in the event of a defect caused either by materials or accessories supplied by or services rendered by Customer or by an intervention by a person or entity which is not authorised or qualified for carrying out such intervent...

Страница 6: ... measures are not respected CAUTION CAUTION indicates possible dangerous situations that can result in minor physical injury or material damage if the safety measures are not respected This symbol refers to supporting information not allowed allowed 7 STORAGE Put all parts to be assembled in a room or at a location where the not yet assembled components are protected against weather influences 8 T...

Страница 7: ...e processed by the local collection agencies 2 In other countries outside the European Union If you want to dispose of this product contact the local authorities for information concerning the correct disposal procedure 10 THE LEVEL OF NOISE EMISSION The noise level of the installation in operation does not exceed 70dB A 11 LOCK OUT TAG OUT LOCK METHOD GENERAL Everyone needs his own lock and tag l...

Страница 8: ......

Страница 9: ...I 1 PART I INSTRUCTIONS FOR THE USER ...

Страница 10: ...COMEO INSTRUCTIONS FOR THE USER ROXELL 001 2415 I 2 ...

Страница 11: ...f the auger stalls immediately switch off the system Carefully read the trouble shooting guide and strictly follow instructions Contact a technically trained person An auger under tension can cause very serious injuries when released 7 Regularly check the elbow trough and or tube connections Tighten if necessary 8 Regularly check that the control unit pan and or the motor handy box are properly cl...

Страница 12: ...in reasons the last line is not enough used by the birds it is possible that the other lines might run empty This can be prevented by using a time clock The time clock should be set such that the feeder is regularly emptied or decreased to a low feed level However you can help to ensure that enough birds eat from the last line by taking care of ventilation house structure insulation litter distrib...

Страница 13: ...or by removing the pans from the 12 fin support You can now easily clean the rotating pans one after another by means of a high pressure cleaner To put back the pan take it in one hand like a dish and push it into the 12 fin support from below With the other hand hold the feed level ring so that the 12 fin support cannot go up ONLY FOR COMEO WITH CLEANING OPTION Follow the steps below when using t...

Страница 14: ...ff less risk that the system runs empty You have better control of the system s performance HOW TO PROGRAMME There are many ways Your house the breed of birds the feed you choose and the possibilities you have as a user determine the best programme The purpose is always the same divide the 24 hour period in 4 segments of 6 hours Each segment has 3 periods is characterized by aperiod of SYSTEM IN O...

Страница 15: ... lines Check level switch X 5 Suspension Check operation of central winch X Check operation of central winch Grease after cleaning X Check connection of cable X Check connection of pulleys X Check suspension of tubes and motors X Keep suspension cord cable in tension X 6 Poultry perch cable above the tubes elbows Check cable X 7 Sensors switches Check operation of safety switch or sensor X Check e...

Страница 16: ...e system Object blocks the auger Motor runs then stalls Feed sticks to the tubes Check if there are no objects in the boot the control unit and the drop holes of the feeder pans Remove any objects 4 Auger stalls Anchor bearing worn out or broken Replace bearing Gently slide auger back into the tubes Don t let it jump back your finger or the bearing could be damaged Auger not enough stretched Short...

Страница 17: ...s empty while the feed level in the second hopper corresponds with the position of the level switch Birds massively move to one side of the house i e depending upon the position of the sun A The problem occurs sporadically You can solve the problem by changing the round hole in the Flex Auger tube above hopper 1 into a rectangular one Install two outlet drops above hopper 1 see fig 3 if necessary ...

Страница 18: ...c operation of control pan 5 7 days 10 12 days FIXED MOVABLE INTERMEDIATE CONTROL PAN AVOID DRAUGHTS for partial brooding AVOID DARKNESS THE MOST USED PAN CHECK THE SUSPENSIONS OF THE 100 KG HOPPER AND THE CONTROL UNIT AF TER HEATING UP THE BUILDING BOTH SUSPENSIONS MUST BE WELL STRETCHED Winch up SUPPORT FOR HOPPER IN LINE OPTION For floor feeding from day old chicks to broilers pans full 0010755...

Страница 19: ...ues by turning the pans a couple of times 180 degrees around the tubes or by removing the pans from the 12 fin supports Protect electrical components against water Clean the whole system by means of a high pressure cleaner max 100 Bar When using aggressive detergents or disinfectants consult your supplier CLEANING COMEO WITH CLEANING OPTION COMEO 1 2 3 4 5 OPTION OPTION 1 2 3 ...

Страница 20: ...ant information concerning this partly completed machinery The method of transmission will be digital The manner in which the information is provided does not prejudice the manufacturer s intellectual property rights concerning the partly completed machinery EN Plaats Datum Place Date Maldegem 01 01 2020 Dhr Gino Van Landuyt Managing Director This part may only be filled out if all built in subpar...

Страница 21: ...204 1 EN 61439 1 EN 61439 2 De EG verklaring van overeenstemming inbouwverklaring betreft uitsluitend de machine of niet voltooide machine in de toestand waarin zij op de markt is gebracht met uitsluiting van de later door bijvoorbeeld de verdeler en of installateur en of eindgebruiker toegevoegde componenten en of verrichte bewerkingen NL Relating to this declaration is in accordance with The fol...

Страница 22: ......

Страница 23: ... COMPONENTS Environmentally friendly design The motors comply with the Ecodesign legislation Communication For all communication concerning parts spare parts refer to the appropriate part number not part name ...

Страница 24: ...ROXELL 009 2416 COMEO COMPONENTS II 2 GENERAL LAY OUT 14 12 13 10 8 6 23 7 5 22 9 16 21 20 4 18 3 17 1 2 15 14 12 13 10 8 6 23 7 5 22 9 16 21 20 4 18 3 17 1 2 15 21 11 20 19 20 24 20 25 ...

Страница 25: ...102681 12 POWER UNIT SEVERAL 13 CONTROL PAN SEVERAL 14 MOTOR STARTER SEVERAL 15 100KG HOPPER 00100602 16 FEED INTAKE BOOT POULTRY 00106500 POULTRY INTAKE BOOT WITH SENSOR 230 V AC 00108952 POULTRY INTAKE BOOT WITH SENSOR 24 V DC 00108950 17 FEEDER PAN SEVERAL 18 AUGER 00100974 19 CABLE 1 16 1 5MM 250M 00106839 CABLE 1 16 1 5MM 500M 00106831 20 TUBE CLAMP ASSY DIAM 45 mm 00102921 21 POULTRY PERCH G...

Страница 26: ...7 COMEO COMPONENTS II 4 ADJUSTER RING REGULATOR 09717153 OPTION AUGER INJECTOR KIT 09701905 2 1 3 Key Name Part Nr Qt 1 AUGER INJECTOR INLET 19700673 1 2 AUGER INJECTOR Ø35 1X50 8 19700749 1 3 AUGER GUIDE 19700780 1 ...

Страница 27: ... 00107025 1 2 FLAT TOPSUPPORT 00901793 1 3 TOPSUPPORT 00900050 1 4 TOPHINGE 00107017 1 5 SHUT OFF SHELL 00105262 1 6 ADJUSTER RING 00108872 1 7 12 FIN PAN SUPPORT 00108888 1 8 SHUT OFF SLIDE 00107053 1 9 SUPPORT CONEW RING 00107001 1 10 SUPPORT CONEW HINGEAND RING 00106977 1 11 STEPPED ROUND FEEDER PAN 00106953 1 ...

Страница 28: ...6 5 4 1 PARTS FOR BROILER CAGE COMEO Key Name Part Nr Qt 1 FLAT TOP SUPPORT 00901793 1 2 ADJUSTER RING 00108872 1 3 12 FIN PAN SUPPORT 00108888 1 4 SHUT OFF SLIDE 00107053 1 5 SUPPORT CONE W RING 00107001 1 6 STEPPED ROUND FEEDER PAN 00106953 1 ...

Страница 29: ... 3 6 5 4 PAN PARTS FOR COMEO FLOOR FEEDING Key Name Part Nr Qt 1 TOPSUPPORT 00900050 1 2 ADJUSTER RING 00108872 1 3 12 FIN PAN SUPPORT 00108888 1 4 SHUT OFF SLIDE 00107053 1 5 SUPPORT CONEW RING 00107001 1 6 STEPPED ROUND FEEDER PAN 00106953 1 ...

Страница 30: ...EANING OPTION POULTRY PERCH GUARD 1 2 3 4 5 6 Key Name Part Nr Qt 1 WIRECONNECTOR 00107025 1 2 TOPHINGE 00107017 1 3 ADJUSTER RING 00108872 1 4 12 FIN PAN SUPPORT 00108888 1 5 SUPPORT CONE W HINGEAND RING 00106977 1 6 STEPPED ROUND FEEDER PAN 00106953 1 ...

Страница 31: ...AR HOLES 00101121 TUBE 2 9 M W 4 RECTANGULAR HOLES 00101113 TUBE 3 05M W 4 RECTANGULAR HOLES 00102301 TUBE 3 05M W 3 RECTANGULAR HOLES 00102293 10 10 6 Key Name Part Nr CHICK STARTER OUTLET ASS Y KIT 50PCS A44869 50 CHICK STARTER OUTLET ASS Y KIT 20PCS A44899 20 EXTENSION TUBE 84 MM 50PCS 41357 50 EXTENSION TUBE 84 MM 20PCS 41357 20 EXTENSION TUBE 122 MM 50PCS 49800 50 EXTENSION TUBE 122 MM 20PCS ...

Страница 32: ... M4x10 DIN 84 4 8 20100806 8 3 TUBE SUPPORT ASS Y 10102390 1 11 NUT M4 20100681 8 4 SCREW LINK DIA 3 5 10203156 1 12 FASTENER 30 1056 MSZN 10201697 1 5 HOPPER HOOK 10105393 1 13 FASTENING HOOK 10102200 1 6 NUT M6 DIN 934 20100210 34 14 HOPPER COVER GRILL 10103075 1 7 HANGER 10102291 1 18 SPRING COTTER ø2 20100749 1 8 BOLT M6 X 12 DIN 933 8 8 20100160 34 HARDWARE KIT 10102341 1 COVER HALF FOR 100KG...

Страница 33: ... 2 4 LOCKNUT M6 DIN 985 20100400 4 5 BOLT M6 X 16 DIN 933 8 8 20100178 4 FEED INTAKE BOOT 00106500 3 5 1 6 4 7 2 TUBE 44 5 mm Key Name Part Nr Qt 1 BOOT BODY WELDMENT 10102192 1 2 REINFORCEMENT HOOK 10107597 1 3 TUBE CLAMP ASSEMBLY DIA 45 MM 00102921 1 4 NUT M5 DIN 934 20100152 2 5 BOLT M5X10 DIN 933 20100111 2 6 ANCHOR BEARING ASS Y 10111441 1 7 DECAL HANDS WARNING 13106596 1 ...

Страница 34: ...M F SENSOR 10112428 1 3 NUT M5 DIN 934 20100152 2 4 HANDY BOX OBO A8 15000037 1 5 SENSOR DISTANCE PIECE 80 MM 10112436 1 6 LOCKNUT M6 DIN 985 20100400 4 7 SENSOR HOLDER 13000443 2 8 SENSOR VC12RT230106821 S3 D1 03103678 1 8 SENSOR VC12 RTM24106821 2 24 230VAC DC 03104586 1 9 REINFORCEMENT HOOK 10107597 1 10 TUBE CLAMPASS Y ø45 10112037 1 11 BOLT M5X10 DIN 933 20100111 2 12 BOLT M6X12 DIN 933 8 8 2...

Страница 35: ... ANCHOR BEARING ASS Y 10111441 2 3 DECAL HANDS WARNING 13106596 2 5 2 3 4 6 1 5 OPTION THUMPER KIT FOR DOUBLE INTAKE BOOT 00106765 Key Name Part Nr Qt 1 DOUBLE THUMPER HOLDER 10111805 2 2 THUMPER STOP 13107982 2 3 THUMPER HOLDER 13107974 2 4 BOLT M6 X 16 DIN 933 8 8 20100178 2 5 LOCKNUT M6 DIN 985 20100400 2 6 THUMPER BODY POULTRY 10107548 2 ...

Страница 36: ...art Nr Qt 1 SENSOR VC12RT230106821 S3 D1 03103678 1 1 SENSOR VC12 RTM24106821 2 24 230VAC DC 03104586 1 2 BOLT M6X12 DIN 933 8 8 20100160 4 3 LOCKNUT M6 DIN 985 20100400 8 4 SENSOR HOLDER 13000443 2 5 HANDY BOX OBO A8 15000037 1 6 SENSOR DISTANCE PIECE 80 MM 10112436 1 7 EXTENS SENS BOX LOCK PLATE 10704104 2 8 EXTENSION FOR SENSOR 03000897 1 ...

Страница 37: ...08888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 TUBEBRACKET ASS Y 10111893 1 6 HARDWARE KIT 10900322 1 7 SWITCH SHIELD 10111941 1 8 LEVEL SWITCH ASS Y 13104500 1 9 WOOD SCREW PK Ø4X25 GALVANIZED 20108924 2 10 SUPPORT PLATEFOR LEVEL SWITCH 10111933 1 11 FLEXTUBEKIXoo VIToo CTRL PAN 15010556 1 12 HINGEJOINT 00101105 1 13 LEVEL SWITCH COMPLETE 00107958 1 00109136 CONNECTION BOX KIT CONTR PAN For U...

Страница 38: ...ED ROUND FEEDER PAN 00106953 1 2 SUPPORT CONE F CONTROL PAN 00107076 1 3 12 FIN PAN SUPPORT 00108888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 TUBEBRACKET ASS Y 10111893 1 6 HARDWARE KIT 10900322 1 7 SENSOR VC12 RT230106821 OFF DELAY 03101185 1 00109136 CONNECTION BOX KIT CONTR PAN For US only to be ordered separately ...

Страница 39: ...107076 1 3 12 FIN PAN SUPPORT 00108888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 TUBE W DROPHOLE 2 EXP ENDS L 240MM 10112029 1 6 LEVEL SWITCH ASS Y 13104500 1 7 PLATE SWITCH 10112005 1 8 SWITCH SHIELD 10111941 1 9 WOOD SCREW PK Ø4X25 GALVANIZED 20108924 2 10 FLEXTUBEKIXoo VIToo CTRL PAN 15010556 1 11 LEVEL SWITCH COMPLETE 00108038 1 00109136 CONNECTION BOX KIT CONTR PAN For US only to be ordere...

Страница 40: ... Nr Qt 1 STEPPED ROUND FEEDER PAN 00106953 1 2 SUPPORT CONEF CONTROL PAN 00107076 1 3 12 FIN PAN SUPPORT 00108888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 TUBEW DROPHOLE 2 EXP ENDS L 240MM 10112029 1 6 SENSOR VC12 RT230106821 OFF DELAY 03101185 1 00109136 CONNECTION BOX KIT CONTR PAN For US only to be ordered separately ...

Страница 41: ...ORT CONE F CONTROL PAN 00107076 1 3 12 FIN PAN SUPPORT 00108888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 LEVEL SWITCH ASS Y 13104500 1 6 SWITCH SHIELD 10111941 1 7 PLATESWITCH 10112005 1 8 WOOD SCREW PK Ø4X25 GALVANIZED 20108924 2 9 FLEXTUBEKIXoo VIToo CTRL PAN 15010556 1 10 LEVEL SWITCH COMPLETE 00108038 1 00109136 CONNECTION BOX KIT CONTR PAN For US only to be ordered separately ...

Страница 42: ... 00107398 Key Name Part Nr Qt 1 STEPPED ROUND FEEDER PAN 00106953 1 2 SUPPORT CONE F CONTROL PAN 00107076 1 3 12 FIN PAN SUPPORT 00108888 1 4 ADJUSTER RING F CONTROL PAN 00108896 1 5 SENSOR VC12 RT230106821 OFF DELAY 03101185 1 00109136 CONNECTION BOX KIT CONTR PAN For US only to be ordered separately ...

Страница 43: ...410 START CAPACITOR 16 µF 09802418 START CAPACITOR 20 µF 09802426 START CAPACITOR 25 µF 09802442 START CAPACITOR 36 43 µF 09802450 START CAPACITOR 56 63 µF 09802458 START CAPACITOR 108 130 µF System Comeo 50 Hz Comeo 60 Hz Gearbox With Key 10106441 Gearbox With F Coupling alu 10111821 10112317 Type Elastic Coupling Set CS 71 80 90 CS71 13204180 CS71 13204180 Motor Shaft Ø14 Ø14 Ratio 3 867 4 73 Ou...

Страница 44: ...Show n 7 2 WIRE NUT 16 GA BLUE 10106607 Not Show n Gearbox With Elastic Coupler Set 10108223 10203909 Motor Shaft Diameter 5 8 Inch 5 8 Inch Speed Ratio 4 73 1 2 52 1 Output Speed RPM 365 685 Construction Size 71 71 Motor Speed 60 Hz RPM 1725 1725 Feed Capacity Lb Hr 1040 1730 P U ASSY 1PH x 115 230V x 60 Hz 00104083 1 2 HP 00201871 1 2 HP MOTOR 1PH x 115 230V x 60 Hz 10109148 1 2 HP 10109148 1 2 ...

Страница 45: ... M12 x 350 10107530 6 SMALL PULLEY WITH STAINLESS STEEL HOOK 00104349 21 NUT M12 DIN 934 20100582 6 PLASTIC PULLEY Ø45MM W ST ST HOOK 00107198 22 SCREW HOOK 90 MM 05000872 7 CABLE ø 5MM 3 16 7x7 00100388 SCREW HOOK 160 MM 05000237 8 CABLE CLAMP NO 5 00100545 23 PLUG DIA 10 MM NYLON 20102034 9 SCREW HOOK M6 X 60 20103156 24 WALL BRACKET FOR HOPPER 10107878 10 NUT M6 DIN 934 20100210 25 HEXAG WOOD S...

Страница 46: ...S PIN 10101723 1 6 SPLIT PIN 3x25 DIN 94 20100533 1 7 PULLEY WHEEL 10101707 1 HEAVY DUTY PULLEY 00100412 Key Name Part Nr Qt 1 NUT M12 DIN 934 20100582 2 2 FOOT 10101657 1 3 SCREW SPINDLE M12 x 350 10107530 1 4 EYENUT M12 20104279 1 5 PULLEY SIDE PLATE SE 10111391 2 6 PULLEY WHEEL 10101707 1 7 CLEVIS PIN 10101723 1 8 SPLIT PIN 3x25 DIN 94 20100533 1 9 BOLT M10X35 DIN 933 20102190 1 10 SPACER 10101...

Страница 47: ...ROXELL 001 1020 COMEO COMPONENTS II 25 HAND OPERATED CENTRAL WINCH 00102368 MOUNTING PLATE F HAND OPERATED CENTRAL WINCH 02001188 TELESCOPICAL WINCH DRIVE ASSEMBLY 00102962 ...

Страница 48: ...3x200 346V 60Hz Motor 11102779 0 3kW 3x254 440V 60Hz Motor 11900842 0 3kW 1x220V 60Hz Motor 10103554 0 37kW 00107214 WINCH W SWITCH CP 3x230V 50Hz 00107222 WINCH W SWITCH CP 3x400V 50Hz 00107230 WINCH W SWITCH CP 1x230V 50Hz 00107238 WINCH W SWITCH CP 3x220V 60Hz 00107246 WINCH W SWITCH CP 3x230V 60Hz 00107254 WINCH W SWITCH CP 3x380V 60Hz 00107262 WINCH W SWITCH CP 3x400V 60Hz 00107270 WINCH W SW...

Страница 49: ...A at 240 V on an AC 15 load The motor must be protected against short circuits and overcurrents in accordance with local regulations You can use a motor starter to switch and protect the motor WARNING Always ensure solid earthing Used in combination with single phase motors 00101030 CONTROL PANEL FOR 1 WINCH MOTOR 00101048 CONTROL PANEL FOR 2 WINCH MOTORS 00101055 CONTROL PANEL FOR 3 WINCH MOTORS ...

Страница 50: ...z 3 PH 230V 3 PH 400V 1 PH 230V 0 18KW 0 22KW 05001233 05001225 05001241 0 25KW 0 30KW 05001233 05001225 05001241 0 37KW 0 44KW 05001241 05001233 05001249 0 55KW 0 66KW 05001249 05001241 05001249 0 74KW 0 90KW 05001249 05001241 05001257 1 10KW 1 32KW 05001257 05001249 05001265 1 25KW 1 50KW 05001257 05001249 05001265 1 50KW 1 80KW 05001265 05001249 05001265 THERMAL MAGNETIC MOTOR PROTECTION WHERE ...

Страница 51: ...ROXELL 001 1020 COMEO COMPONENTS II 29 CONTROL PANEL WITH TIME CLOCK 00100685 BOX W COUNTER 00102905 OPTION CONTROL PANEL INTERMEDIATE CONTROL UNIT 05000922 ...

Страница 52: ...100160 8 6 LOCKNUT M6 DIN 985 20100400 4 7 HARDWARE KIT 10107431 1 7 1 S HOOK 05000013 1 7 2 CHAIN Ø2 5 LG 149MM 10107449 1 7 3 WASHER Ø34X20X3 DIN 126 20100483 1 7 4 SOCKET CAP SCREW M6X35 20102158 1 7 5 FLAT ROUND HEAD SCREW M8X16 20104196 1 7 6 SCREW LINK Ø3 5 10203156 1 7 7 DRIVE BLOCK 10100782 1 8 WASHER D 6 6X12X1 6 DIN 126 20100459 2 END UNIT 00901827 4 1 8 5 3 2 6 7 4 7 5 7 7 7 1 7 2 7 3 7...

Страница 53: ...RT 10203107 1 1 4 PARCKER SCREW 4 2x9 5 DIN 7981 20102745 2 1 5 MINIMUM SWITCH SHIELD 10203115 1 1 6 ADHESIVE TAPE19X0 23 2SIDE 30800726 2 1 7 PARKER SCREW 4 2x19 DIN 7981 20104535 2 2 HANDY BOX OBO A8 15000037 1 3 SCREW M5X12 DIN 84 4 8 20101135 2 4 NUT M5 DIN 934 20100152 2 5 CABLERING PG 9 15001472 2 6 CABLERING HOLDER 2xPG9 15010119 1 7 CLAMPSTROKE27 20 6E 3 10103109 1 8 SWITCH CORD GUARD 1310...

Страница 54: ... 2 2 FRONT BACK PLATE EXTENSION BOX 10900389 2 3 TOP PLATE EXTENSION BOX 10900405 1 4 NUT M6 DIN 934 20100210 12 5 SOCKET CAP SCREW M5X10 DIN 912 20103149 2 6 LOCKNUT M5 DIN 985 20100392 2 7 S HOOK 05000013 2 8 SOCKET CAP SCREW M6X10 DIN 912 20101713 12 9 HOSE CLAMP Ø90 110 00105726 2 10 PARCKER SCREW 8X1 2 20100525 1 FLEXIBLE CONNECTION BOX 00106757 ...

Страница 55: ...OR CONTROL UNIT 00108158 Key Name Part Nr Qt 1 POWER SUPPLY 12VDC 6W 10112245 1 2 LEDBAR 100LUMEN LG 550MM 10112237 1 LED LIGHT KIT F INTERM CONTROL UNIT 00108166 Key Name Part Nr Qt 1 POWER SUPPLY 12VDC 6W 10112245 1 2 LEDBAR 100LUMEN LG 550MM 10112237 1 2 1 ...

Страница 56: ... BEAR CAP HOLDER Ø44 5 SET 10PCS 00106929 10 FEED INTAKE BOOT POULTRY POULTRY INTAKEBOOT WITH SENSOR POULTRY INTAKEBOOT WITH SENSOR 230VAC DOUBLEFEED INTAKE BOOT Used in 00106500 00108950 00106518 00108952 SPARES SET BEAR CAP HOLD Ø44 5 SET 10 PCS 00106929 ...

Страница 57: ...PART III INSTALLATION INSTRUCTIONS ...

Страница 58: ...HAIKOO INSTALLATION INSTRUCTIONS ROXELL 009 2313 ...

Страница 59: ... the SUSPENSION POINTS Firmly tighten ALL CABLE CLAMPS WINCH UP THE FEEDER LINES THREE TIMES and lower them again full course NEVER STAND UNDERNEATH THE SYSTEM when doing this Winching up and lowering must proceed WITHOUT ANY HITCH 4 At the FIRST START UP make sure that if the auger HITCHES or BLOCKS you can IMMEDIATELY SWITCH OFF the system with the main switch on the control panel GENERAL SAFETY...

Страница 60: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 4 GENERAL LAY OUT 14 12 13 10 8 6 23 7 5 22 9 16 21 20 4 18 3 17 1 2 15 14 12 13 10 8 6 23 7 5 22 9 16 21 20 4 18 3 17 1 2 15 21 11 20 19 20 24 20 25 ...

Страница 61: ...ACKET 00102681 12 POWER UNIT SEVERAL 13 CONTROL PAN SEVERAL 14 MOTOR STARTER SEVERAL 15 100KG HOPPER 00100602 16 FEED INTAKE BOOT POULTRY 00106500 POULTRY INTAKE BOOT WITH SENSOR 230 V AC 00108952 POULTRY INTAKE BOOT WITH SENSOR 24 V DC 00108950 17 FEEDER PAN SEVERAL 18 AUGER 00100974 19 CABLE 1 16 1 5MM 250M 00106839 CABLE 1 16 1 5MM 500M 00106831 20 TUBE CLAMP ASSY DIAM 45 mm 00102921 21 POULTRY...

Страница 62: ...STRUCTIONS ROXELL 009 2218 III 6 TOOLS Ø9 Ø7 Ø2 8 Ø6MM 09700220 19700236 Ø32 SENSOR 09701699 Ø40 09700022 MOD 55 Ø51 09700030 MOD 75 Ø70 09700048 MOD 90 Ø108 09700055 MOD 125 Ø130MM Holes in wall 09700071 09717153 09717145 ...

Страница 63: ...V N IEC38 3x230V MAXIMUM CABLE LENGTHS TO THE MOTORS SEE PAGE III 60 FIGURE 1 FA II FA I 1 2 2 9 3 3 4 5 6 3x380V N 3x415V N 3x400V N IEC 38 3x200V 3x220V 3x230V IEC 38 3x240V Control unit 7 8 7 3 8 8 1 Supply cable 4x2 5 2 5 2 Cable Flex Auger power units 3x2 5 2 5 3 Cable power units 3x2 5 2 5 4 Cable max sensor weigher 4x1 5 safety switch FA II 2x1 5 5 Cable impulse switch weigher 2x0 75 0 75 6...

Страница 64: ...forces WEIGHT POWER UNIT RESULTING FORCE On hopper suspension 55LBS DANGER On standard pulley 44LBS On power unit suspension RESULTING FORCE Each suspension point small pulley should be able to hold a 100 kg burden Each fixing of the heavy duty pulley should be able to hold a burden of 3 X F RESULTING FORCE Drill a small hole in HARD WOOD This will prevent screw hooks from breaking off Use a drill...

Страница 65: ...VER MAKE THE INSTALLATIONS LONGER THAN THE RECOMMENDED LENGTH DRAWINGS OF SUSPENSION SYSTEM WITH CENTRAL WINCH DANGER L 3 M 00100412 HEAVY DUTY PULLEY 00100750 CHAIN DIAM 3 5 MM 00104349 SMALL PULLEY WITH STAINLESS STEEL HOOK 00100610 SUSPENSION CORD 00102368 HAND OPERATED CENTRAL WINCH 00100420 SINGLE EYE PULLEY 00100388 CABLE ø 5 MM 3 16 7x7 05000872 SCREW HOOK 90MM 00100545 CABLE CLAMP NO 5 001...

Страница 66: ...out of line Cable Feeder line 25cm 15cm 25cm 25cm 25cm 15cm 15cm 15cm 0cm 0cm CHOOSE BETWEEN 2 FOLLOWING POSSIBILITIES SO THE CABLE CLAMPS WILL NOT TOUCH THE PULLEYS WHEN YOU WINCH UP THE LINE FIGURE 11 Place suspension hooks crosswise off the beam center line 00100388 MAIN CABLE MAIN CABLE MAIN CABLE ...

Страница 67: ...F THE WINCH IS 800 KG INSTALL THE WINCH AT A SOLID SPOT IN THE ROOF CONSTRUCTION REINFORCE WHEN NECESSARY CENTRAL WINCH 20100426 02001188 20102190 OPTION Fix the winch to the plate with bolts and locknuts Fix this plate to the ceilings before the insulation Pay attention to the cor rect direction FIGURE 13 CENTRAL WINCH W GEARBOX MOTOR OPERATED supplied with MOUNTING PLATE Install the motor after ...

Страница 68: ...6 III 12 FIGURE 14 MAKE SURE THAT THE MAIN CABLE 5mm DOES NOT HANG IN BUT BESIDE THE SCREW HOOKS AND PULLEYS SUSPENSION FOR FEEDER LINE SUSPEND THE CONTROL UNIT AT LEAST 3M FROM THE HOUSE END WALL FIGURE 15 00100388 MAIN CABLE MAIN CABLE MAIN CABLE ...

Страница 69: ...CABLE IN THE SCREW HOOKS FOR THE TIME BEING Measure the distance from the wall to the first feeder line Mark from this spot the suspension points on the ceiling over the whole length of the line Alternat ives see page III 8 FIGURE 16 MAIN CABLE CENTRAL WINCH FIGURE 17 00104349 05000872 3m 3m FIGURE 18 FIGURE 19 00100412 00100412 3m 3m ...

Страница 70: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 14 FIGURE 20 TO INSTALL THE MAIN CABLE ...

Страница 71: ...L 009 2415 COMEO INSTALLATION INSTRUCTIONS III 15 SINGLE DIVERSION FIGURE 21 FIGURE 22 FEEDER LINE 85 9M SEE PAGE III 9 FIGURE 9 FIGURE 23 Required cable length 4 x height Required cable length 4 x height H ...

Страница 72: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 16 FIGURE 24 FIGURE 25 00102699 7 1 2 3 4 5 6 1 2 3 ...

Страница 73: ...ROXELL 009 2415 COMEO INSTALLATION INSTRUCTIONS III 17 FIGURE 26 CENTRAL WINCH W GEARBOX 2x FIGURE 27 FIGURE 28 FIGURE 29 FIGURE 30 ...

Страница 74: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 18 FIGURE 31 FIGURE 32 1 2 4x 4x 4x 4x FIGURE 33 00100412 00100545 00107198 OVERVIEW ...

Страница 75: ...OXELL 009 2415 COMEO INSTALLATION INSTRUCTIONS III 19 FIGURE 34 TIGHTEN MAIN CABLE 15 kg FIGURE 35 15cm 55cm H 3cm 2cm L H 55 2 3 15 15cm CUT BY MEANS OF A SOLDERING IRON OR AN ELECTRICALLY HEATED KNIFE ...

Страница 76: ...OXELL 001 4918 III 20 TO INSTALL THE LINE FIGURE 36 POSSIBLE FEEDER PAN COMBINATIONS COMEO FLOOR FEEDING PERCH GUARD FIGURE 37 00900050 00108872 00108888 00107053 00107001 00106953 00106977 00107017 00107025 00108872 00108888 00106953 ...

Страница 77: ...009 2415 COMEO INSTALLATION INSTRUCTIONS III 21 FIGURE 38 POSSIBLE FEEDER PAN COMBINATIONS COMEO BROILER CAGE FIGURE 39 00901793 00107009 00106961 00107001 00106953 00106977 00107017 00107009 00106961 00106953 ...

Страница 78: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 4918 III 22 FIGURE 40 TO INSTALL THE FEEDER PANS 00108872 1 2 FIGURE 41 3x 09717145 FIGURE 42 1 2 1 2 1 2 3 4 CLICK 3 ...

Страница 79: ...ROXELL 009 2415 COMEO INSTALLATION INSTRUCTIONS III 23 FIGURE 43 FIGURE 44 FIGURE 45 FIGURE 46 2mm 3mm 3x OPTION ...

Страница 80: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 24 FIGURE 47 CLICK 12x FIGURE 48 FIGURE 49 FIGURE 50 FIGURE 51 OPTION 00101105 1 2 3 4 ...

Страница 81: ...ROXELL 009 2415 COMEO INSTALLATION INSTRUCTIONS III 25 FIGURE 52 FIGURE 53 FIGURE 54 Welding seam FIGURE 53 ...

Страница 82: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 26 FIGURE 54 FIGURE 55 CLICK CLICK 2x 2x ...

Страница 83: ...ROXELL 009 2415 COMEO INSTALLATION INSTRUCTIONS III 27 FIGURE 56 CLICK CLICK 1 2 90 FIGURE 57 CLICK CLICK ...

Страница 84: ...OMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 28 FIGURE 58 COMEO FLOOR FEEDING PERCH GUARD FIGURE 59 00900050 00107009 00106961 00107053 00107001 00106953 00900050 00107053 00107001 1 2 3 5 4 1 1 2 ...

Страница 85: ...ROXELL 001 4918 COMEO INSTALLATION INSTRUCTIONS III 29 FIGURE 60 FIGURE 61 COMEO FLOOR FEEDING PERCH GUARD 00106977 00107017 00107025 00108872 00108888 00106953 1 2 3 4 5 ...

Страница 86: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 4918 III 30 FIGURE 62 COMEO BROILER CAGE FIGURE 63 00901793 00108872 00108888 00107001 00106953 1 2 3 4 1 1 2 ...

Страница 87: ...ROXELL 009 4016 COMEO INSTALLATION INSTRUCTIONS III 31 FIGURE 64 1 FIGURE 65 1 2 3 4 5 6 3x 6x OPTION Right Left CLOSED OPEN CLICK CHICK STARTER OUTLET ASS Y KIT OPTION Sandpaper CLICK ...

Страница 88: ...TALL THE SHUT OFF SLIDE FOR PARTIAL STARTING REAR FIGURE 66 FIGURE 67 Running direction of the feed Partial starting area 00104133 FOR PARTIAL STARTING FRONT FIGURE 68 FIGURE 69 Running direction of the feed Partial starting area Intermediate control pan 00104133 ...

Страница 89: ... COMEO INSTALLATION INSTRUCTIONS III 33 TOTAL HOUSE BROODING FIGURE 70 Running direction of the feed 00108264 00108264 100kg hopper FIGURE 71 TO INSTALL THE FEEDER LINE INSTALL AN ANCHOR BRACKET 1 2 10mm 00102921 10Nm ...

Страница 90: ... line is suspended REMARK AFTER INSTALLATION OF THE PANS WHEN THE LINE HANGS LEVEL YOU CAN INSERT THE CORD END BACK INTO THE CORD THIS ADDS TO THE HEIGHT THE LINE CAN BE RAISED AND ALLOWS A NEATER FINISH 00100792 FIGURE 73 OPTIONAL Cable 3 32 00106887 250M 00106895 500M TO START SUSPEND ALL CABLES UNDER SLIGHT TENSION 00602060 00100354 1 2 3 4 5 6 ...

Страница 91: ...e feeder line Partial starting area MOVABLE INTERMEDIATE CONTROL UNIT FOR PARTIAL STARTING 5 3 FIGURE 74 75 76 TO INSTALL THE INTERMEDIATE CONTROL FIGURE 75 FIGURE 76 TO INSTALL THE TUBE WITH HOLE 150mm FIXED INTERMEDIATE CONTROL UNIT FOR PARTIAL STARTING 77 FIXED INTERMEDIATE CONTROL UNIT FOR PARTIAL STARTING ...

Страница 92: ...sy use and or switching over from a partial area to full use of the house you can make advant age of a control panel intermediate control unit optional 1 intermediate control unit 2 intermediate control units control unit with sensor at the end 1 and 2 Position of the switch 1 or 2 depending on the brooding area in the house E Use of OFF START STOP ...

Страница 93: ...ROXELL 009 4016 COMEO INSTALLATION INSTRUCTIONS III 37 FIGURE 79 FEED INTAKE BOOT OPTION SUPPORT FOR HOPPER IN LINE 1 2 3 FIGURE 80 5 6 4 ...

Страница 94: ... INSTALLATION INSTRUCTIONS ROXELL 001 2119 III 38 Install as shown on page II 10 FIGURE 81 TO INSTALL AND SUSPEND THE 100KG HOPPER HEIGHT ADJUSTMENT OF THE 100KG HOPPER FIGURE 83 Chain 3 5mm Hopper hook 1 2 ...

Страница 95: ...ROXELL 009 4016 COMEO INSTALLATION INSTRUCTIONS III 39 FIGURE 83 TO INSTALL THE CONTROL UNIT POWER UNIT SUSPENSION FIGURE 84 05000013 10203156 10107449 00100545 1 ...

Страница 96: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 40 FIGURE 85 CONNECTION BOX KIT FOR CONTROL PAN FOR US ONLY FIGURE 86 ...

Страница 97: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 41 FIGURE 87 20100244 10112548 FIGURE 88 ...

Страница 98: ...ON INSTRUCTIONS ROXELL 001 1020 III 42 FIGURE 89 TAKE CARE THAT THE AUGER DOES NOT UNROLL FIGURE 90 FIGURE 91 FIGURE 92 FIGURE 93 4 m 09701905 1 2 3 4 FIGURE 94 20100483 10100782 20102158 TO INSTALL THE AUGER OPTION 5 ...

Страница 99: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 43 FIGURE 95 6 FIGURE 96 ...

Страница 100: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 44 FIGURE 97 4x FIGURE 98 1 2 ...

Страница 101: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 45 FIGURE 99 00901827 OPTION for cages Overflow box FIGURE 100 1 7cm per 3m tube M NM FIGURE 101 M ...

Страница 102: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 46 FIGURE 102 1 2 FIGURE 103 FIGURE 104 ...

Страница 103: ...end a bronze flux coated rod The joint must be well filled Avoid sharp edges or rough corners these wear out the tubes Braze at low temperature Weld length Min 1 4 of the auger circumference up to Max 1 3 of the auger circumference FIGURE 105 FIGURE 106 AUGER BRAZING All th j i t t i l R id li k th j i t b ittl d b k bl ...

Страница 104: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 48 Perforate the prepunched holes TO INSTALL THE THUMPER OPTION SECTION FIGURE 108 FIGURE 109 FIGURE 110 ...

Страница 105: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 49 ADJUSTMENT ADJUSTMENT Left Right FIGURE 111 1 Max 2 Min 1 Max 2 Min A B Right Left FIGURE 112 ...

Страница 106: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 50 ADJUSTMENT LIMIT SWITCH FIGURE 113 1 Max 2 Min CONNECTION DIAGRAM SEE CP CENTRAL WINCH 1 2 2 1 FIGURE 114 ...

Страница 107: ...1 1020 COMEO INSTALLATION INSTRUCTIONS III 51 TO INSTALL THE POULTRY PERCH GUARD FIGURE 115 Make a double loop around the central notch of the anchor bracket FIGURE 116 00102681 00102921 00106945 00900050 1 2 3 ...

Страница 108: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 52 FIGURE 117 20 00107025 20 Comeo with cleaning option FIGURE 118 FIGURE 119 EVERY 3 FEEDER TUBES FIGURE 120 10107472 ...

Страница 109: ...65mm Cable tie After all cables for poultry perch have been installed connect the poultry perch guard to the 1 16 cable FIGURE 122 Socket Poultry perch guard Earthing Earthing per line Important use only cable for poultry per ch ignition cable 1mm2 POULTRY PERCH GUARD AND FEEDER LI NE MUST BE EARTHED ...

Страница 110: ...OR S MANUAL ATTENTIVELY READ THESE INSTRUCTIONS TO INSTALL THE FLEX AUGER FEED SUPPLY SYSTEM ATTENTION USE AS LITTLE ELBOWS AS POSSIBLE MAKE SURE THAT THERE ARE NO TUBE CONNECTIONS AT LOCATIONS WHERE YOU NEED OUTLET DROPS Drop tube Telescopical tube Outlet drop Control unit Power unit FIGURE 123 FIGURE 124 ...

Страница 111: ...ATION INSTRUCTIONS III 55 TO INSTALL THE TELESCOPICAL TUBE FIGURE 125 Tube clamp w S hook Chain dia 3 5 S hook Screw link Cut a hole in the cover at any desired loca tion 100Kg Hopper Hook for 100kg hopper FIGURE 126 FIGURE 127 30 ...

Страница 112: ...N HOPPER UNDER WEIGHER 1 4 3 SMINW1 MIN SENSOR IN HOPPER UNDER WEIGHER BR M Time clock Thermal magnetic motor pro tection with auxiliary contacts Main Switch Sensor with NO contact supply on Sensor with NC contact supply on Control sensor for Kixoo or Boozzter pans Safety or level switch for Flex Augers Discaflex 2 position switch with 0 1 indication plate 3 position switch with M 0 A indication p...

Страница 113: ... 2T1 4T2 6T314NO A2 1L1 3L2 5L313NO A1 L1 L2 PE L1 L2 PE L2 L1 PE L2 PE L2 PE L1 L2 PE L1 2 1 2 1 1 2 2 1 6 3 12 Ca Cb Z2 U2 V2 U1 V1 Z1 1 2 1 2 2 1 Sw1 Sw2 Sw1 Sw2 Connection of start stop conditions Start stop condition Level switch Level switch Junction box Junction box Control unit Control unit From motor starter FEEDER PAN 100kg hopper 1x230V AC IEC38 Safety switch Max total power 2hp UL or 3...

Страница 114: ...UM CABLE LENGTHS TO THE MOTORS SEE PAGE III 138 Connection of start stop conditions Start stop condition Level switch Level switch Junction box Junction box Control unit Control unit From motor starter FEEDER PAN 100kg hopper 3x230V AC IEC38 Sense of rotation of the auger see arrow on power unit Attention Compare setting of motor protection with data on motor name plate Safety switch Max total pow...

Страница 115: ... U2 V2 U1 V1 W1 Level switch Level switch Junction box Junction box 6 3 12 1 2 1 2 2 1 Sw1 Sw2 Sw2 Sw1 Control unit Control unit From motor starter FEEDER PAN 100kg hopper 3x400V AC N IEC38 Sense of rotation of the auger see arrow on power unit Attention Compare setting of motor protection with data on motor name plate Safety switch Max total power 7 5hp UL or 5 5 kW CONNECT EXTRA START STOP CONDI...

Страница 116: ...UCTIONS ROXELL 001 1020 III 60 LED LIGHT KIT FOR CONTROL UNIT FIGURE 128 1 30 2 00108158 20101614 2x FIGURE 129 CONNECT THE POWER SUPPLY TO 100 240 VAC 50 60HZ 0 22A CU FIGURE 130 20103149 20100400 20100160 2x 2x 2x FIGURE 131 ...

Страница 117: ...NSTALLATION INSTRUCTIONS III 61 FIGURE 132 LED LIGHT KIT FOR INTERMEDIATE CONTROL UNIT 20101812 CONNECT THE POWER SUPPLY TO 100 240 VAC 50 60HZ 0 22A CU 00108166 CONNECT THE POWER SUPPLY TO 100 240 VAC 50 60HZ 0 22A CU 30 4x ...

Страница 118: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 62 MOTOR PROTECTION 1 STOP START OFF 1L1 3L2 5L3 2T1 4T2 6T3 1 6 Type IP55 CL F S1 Hz V kW min 1 ...

Страница 119: ...2ME03 0 1232 1 5 1233 2053 2 5 2054 3285 4 0 18 1x230V 50Hz GV2ME07 0 110 1 5 111 185 2 5 186 297 4 3x230V 50Hz GV2ME06 0 174 1 5 175 290 2 5 291 464 4 3x400V 50Hz GV2ME05 0 492 1 5 493 821 2 5 822 1314 4 0 22 3x220V 60Hz 3x230V 60Hz GV2ME06 0 167 1 5 168 279 2 5 280 446 4 3x380V 60Hz 3x400V 60Hz GV2ME05 0 471 1 5 472 785 2 5 786 1257 4 0 25 1x230V 50Hz GV2ME07 0 110 1 5 111 185 2 5 186 297 4 3x23...

Страница 120: ...00V 50Hz GV2ME06 0 308 1 5 309 513 2 5 514 821 4 0 75 1x230V 50Hz GV2ME10 0 44 1 5 45 73 2 5 74 117 4 3x230V 50Hz GV2ME08 0 69 1 5 70 116 2 5 117 185 4 3x400V 50Hz GV2ME07 0 197 1 5 198 328 2 5 329 525 4 0 9 1x220V 60Hz 1x230V 60Hz GV2ME14 0 26 1 5 27 44 2 5 45 71 4 3x220V 60Hz 3x230V 60Hz GV2ME10 0 42 1 5 43 70 2 5 71 113 4 3x380V 60Hz 3x400V 60Hz GV2ME08 0 117 1 5 118 196 2 5 197 314 4 1 1 3x230...

Страница 121: ...27 44 2 5 45 71 4 3x380V 60Hz 3x400V 60Hz GV2ME10 0 74 1 5 75 124 2 5 125 199 4 2 2 3x230V 50Hz GV2ME14 0 27 1 5 28 46 2 5 47 74 4 3x400V 50Hz GV2ME10 0 78 1 5 79 130 2 5 130 208 4 2 64 3x380V 60Hz 3x400V 60Hz GV2ME14 0 47 1 5 48 78 2 5 79 125 4 In reality if the cable lengths are longer than the ones given in the tables above then you have to take one of the following actions Double the section o...

Страница 122: ...xell com www roxell com ROXELL Malaysia No 49 Jalan Permata 2 KS9 Taman Perindustrian Air Hitam 41200 Klang Selangor Malaysia Tel 60 3 3123 1767 info malaysia roxell com www roxell com ROXELL Россия ООО Рокселл ОГРН 1157746055026 125167 Россия город Москва Ленинградский проспект дом 37 корпус 9 помещение 653 Телефон 7 495 983 30 15 Адрес электронной почты info russia roxell com www roxell com ...

Отзывы: