background image

ROWAN ELETTRONICA  S.R.L. - Via Ugo Foscolo, 20 - 36030 CALDOGNO (VICENZA)  ITALY

6

DESCRIPTION OF TRIMMERS

P1 max torque limitation if adjusted counter-clockwise, it limits max voltage to motor windings (active with

microswitch S2 closed).

P2 minimum torque if adjusted clockwise, it increases min voltage to motor windings (active with microswitch

S2 closed).

P3 acceleration/deceleration ramp min 20 mSec, max 8 Sec.

P4 max speed regulates motor max speed with speed regulation potentiometer at maximum and in any case with

input on terminal 5 = +10VDC. Turned clockwise, it increases speed.

P5 min speed regulates motor min speed with speed regulation potentiometer at minimum and in any case with

input on terminal 5 = 0VDC. Turned clockwise, it increases speed.

P6 stability: to be regulated clockwise to stabilise any oscillations in the control of speed if regulation of trimmer

P7 was not sufficient (proportional / integral action).

P7 stability: to be regulated in a counter-clockwise direction to stabilise any oscillations in the control of speed

(integral action).

DESCRIPTION OF MICROSWITCHES

S1 open: activates external torque limitation from potentiometer or from 0+10VDC signal connected to terminal 3

closed: activates board internal torque limitation from trimmer P1

S2 open: cuts out torque limitation

closed: activates torque limitation

S3 open: in case of 3 wire speed regulation potentiometer connection

closed: in case of 2 wire speed regulation potentiometer connection

S4 open: in case of connection to 2 pole motor

closed: in case of connection to 4 pole (or 6 pole) motor. In case of 6 pole motor recalibrate maximum speed

with P4 until the tachogenerator generates a maximum voltage of 6 VDC.

S5 open: in case of maximum precision in controlling speed (minimum shift from loadless to loaded)

closed: enchances prompter response in speed change transients to the detriment of precision (greater shift

from loadless to loaded)

DESCRIPTION OF DISPLAYS

L1 POWER ON: indicates power supply flowing through the board and driving circuit.

L2 RUN: when on indicates that motor rotation has been enabled with the opening of run consent  contact (AR)

at terminals 1 - 2. It illuminates in proportion to the voltage to motor windings.

L3 TACHOMETER GENERATOR PRESENCE: when on indicates that motor is rotating and that tachometer

generator voltage is available at terminals 7 -8. Tachometer generator voltage is directly proportional to motor
speed and assumes a value of approximately 20VDC at 2800 tpm.

Содержание 119/92

Страница 1: ...NUAL CODE119 92 REV 7 Date 15 10 18 EMC CONFORMITY FORASYNCHRONOUS ROWAN SINGLE PHASE MOTORS with TACHOMETER Motori azionamenti accessorieserviziperl automazione Via Ugo foscolo 20 CALDOGNO VICENZA IT...

Страница 2: ...any inaccuracies contained in this manual due to printing and or transcription errors ROWAN ELETTRONICA s r l reserves the right to make any variations that it considers necessary for better function...

Страница 3: ...ally through potentiometer or 0 10Vdc signal Input for pure contact or NPN open collector transistor for static run stop command 12Vdc 2mA Internal regulations through trimmer for acceleration deceler...

Страница 4: ...ed system extremely silent Absence of typical PWM whistle and uniform from zero to the maximum motor rounds The application of controlled diodes on the power part gives reliability against extravoltag...

Страница 5: ...3kohm load regulation external potentiometers 1 5 speed regulation 0 10VDC signal input 0VDC zero turns 10VDC max speed 1 extreme 3 cursor torque limitation external potentiometer connection 4 extreme...

Страница 6: ...terorfrom0 10VDCsignalconnectedtoterminal3 closed activates board internal torque limitation from trimmer P1 S2 open cuts out torque limitation closed activatestorquelimitation S3 open in case of 3 wi...

Страница 7: ...l it can be used for analog revolution counters display counters or other servomechanisms provided the overall loading being not lower than 5Kohm maxtachometercurrent 5mA Itisalwaysnecessary toavoidin...

Страница 8: ...te it means that tachometer dynamo voltage is not reaching terminals 7 and 8 when this happens check the connections again Check attainment of maximum speed and if necessary fine adjust the maximum va...

Страница 9: ...oswitch S1 and limit torque by regulating trimmer P1 Speed torque control from analog signal 0 10VDC In code 119 92 speed and torque regulations in addition to the conventional manual potentiometer ca...

Страница 10: ...sets the ramp and switches off RUN led L2 If motor run stop were necessary with acceleration and deceleration ramps without immediately removing voltage from the motor in its stopping phase perform th...

Страница 11: ...ve the screws attaching the brake to the hub 4 disconnect the brake cable from the terminal block 5 slide the brake off the hub At this stage the calibration can be made by adjusting the 3 bolts until...

Страница 12: ...of motor windings with relative terminal board covering 9 FEET for B3 or B3 B5 versions 10 THERMICSENSORINSIDEWINDINGS 11 COMPENSATORRING 12 REAR RING for rear bearing housing 13 SERVICE TERMINAL BOA...

Страница 13: ...r but according to an exponential curvewhichpresentsstrongvariationsatslowspeedandsmallvariationsathighspeed Ifonewishestoavoidthis behaviour and obtain a variation directly proportional to potentiome...

Страница 14: ...of board C120 121 proceed as follows shift the wire connected to terminal NEG to terminal 1 of C119 92 shift the wire connected to terminal AR to terminal 2 of C119 92 exclude the wire connected to t...

Страница 15: ...ROWAN ELETTRONICA S R L Via Ugo Foscolo 20 36030 CALDOGNO VICENZA ITALY BLOCK DIAGRAM...

Страница 16: ...Foscolo 20 36030 CALDOGNO VICENZA ITALY EMC CONFORMITY Motori azionamenti accessorieserviziperl automazione Via Ugo foscolo 20 CALDOGNO VICENZA ITALY Tel 0039 444 905566 Fax 0039 444 905593 E mail inf...

Отзывы: