SAFETY FEATURES
A Hi-Limit Control turns off electric power
to the heaters and control circuits if the unit
overheats. To reset the control, allow 10-15
minutes for the unit to cool, then locate
the Hi-Limit Control on the rear of the unit.
Remove the black protective cap, press the
button, and reinstall the protective cap.
NOTE: If the Hi-Limit Control requires con-
tinuous resetting, contact your Authorized
Service Agency.
FAULT MESSAGES
The Control Display will flash fault messages
when there is a problem with the unit.
“
HI
” will flash if the Platen Heater tempera-
ture is 30°F more than the setpoint or if the
Platen Thermocouple is disconnected or open.
“
HI
” and “
USE
” will flash if the Auxiliary
Heater temperature is 50°F more than the
setpoint or if the Auxiliary Thermocouple is
disconnected or open.
“
CHEC
” will flash when the control compart-
ment ambient temperature is more than 150°C
(66°C). All heaters will shut off. The unit will
not restart until the control compartment
ambient temperature falls below 140°F (60°C).
“
PO
” will flash if the incoming power drops
below 190 volts. The toaster will shut down.
“
StoP
” will flash when the motor has stopped
for seven continuous seconds.
“
SpEd
” will flash when the motor speed has
dropped 25% below the setpoint for 30 con-
tinuous seconds.
ERROR CODES
If any of the following Error Codes appear, turn
the power off, allow the unit to cool, and turn
the power back on. If the error repeats, contact
your Authorized Service Agency for assistance.
ERR 1
: Internal error. Cycle the Power Switch.
If error persists, replace the board.
ERR 2
: Internal error. Cycle the Power Switch.
If error persists, replace the board.
ERR 3
: Internal error. Cycle the Power Switch.
If error persists, replace the board.
ERR 4
: Invalid DIP Switch setting. The only
approved setting is (left to right) up-
up-up-down (1 on; 2, 3, 4 off).
ERR 5
: Internal error. Cycle the Power Switch.
If error persists, replace the board.
ERR 6
: Internal error. Cycle the Power Switch.
If error persists, replace the board.
ERR 7
: Not used.
ERR 8
: Shorted Platen Thermocouple.
ERR 9
: Open Platen Thermocouple.