background image

5

P/N 1010678 Rev. K 08/12

INSTALLATION

NOTE: When placing the unit, make sure 
to provide at least 3 inches of space on 
all sides of the unit.

1.  Remove unit and all packing materials 

from shipping carton.

2.  The unit should come with the items 

listed below:

• 

Owner’s Manual

• 

Authorized Service Agency Directory

• 

Inlet Hose Assembly (DFW/DFWT/
DFWF-200/250 only).

NOTE: If any parts are missing or dam-
aged, contact Antunes Technical Service 
IMMEDIATELY at 1-877-392-7854 or 
1-630-784-1000.

3.  Remove all packing materials and  

protective coverings from the unit.

4.  Remove and wash the Pan, Trivet, and 

Diffuser in soap and water. Rinse with 
clean water and allow to air dry.

NOTE: The steam generator surface 
(Figure 6) will have a white coating of 
artificial lime deposits. This coating is 
necessary for steaming characteristics.

5.  Wipe all surfaces of the unit with a 

hot damp cloth.

NOTE: Do NOT use a dripping wet cloth. 
Wring out before use.

6.  Re-install Pan, Trivet, and Pan Diffuser.

When placing the unit into service, pay atten-
tion to the following guidelines.

• 

Make sure to provide at least 3 inches 
of space on all aides of the unit.

• 

Make sure the power switch is off and 
the unit is at room temperature before 
plugging in the power cord.

• 

Do not block or cover any openings 
on the unit.

• 

Do not immerse the power cord or 
plug in water.

• 

Keep the power cord away from 
heated surfaces.

• 

Do not allow the power cord to hang 
over edge of table or counter.

Plug the power cord into the appropriate 
power outlet. Refer to the specification 
plate for the proper voltage.

PLUMBING

DFW models are designed to use cold tap 
water. Distilled water may be used to reduce 
calcium/mineral deposit buildup and reduce 
maintenance costs.

MODELS DFW/DFWT-100/150

The DFW/DFWT-100/150 models have a self-
contained water tank. To fill the tank:

1.  Open the tank cover on the top of 

the unit.

NOTE: Make sure the filter inside the tank 
is installed properly.

2.  Pour in cold tap water. The tank will 

hold approximately 3 quarts (2.81 
liters). Do not overfill the tank.

3.  Close the tank cover.

MODELS DFW/DFWT/DFWF-200/250

The DFW/DFWT/DFWF-200/250 models require 
a direct cold water hookup. A water inlet hose 
and strainer assembly (Figure 1) is supplied.

Incoming water is controlled by a normally 
closed solenoid valve located inside the 
steamer’s electrical housing. 

1.  Turn off the water valve (not supplied) 

that provides water to the unit.

2.  Connect the 1/4" (6.5 mm) ID flexible 

tubing to the outlet side of the water 
pressure regulator and secure using 
the worm clamp.

NOTE: A Water Pressure Regulator must 
be installed. Failure to do so will result 
in poor steaming and possible flooding. 
For a single steamer, use Water Pressure 
Regulator P/N 7000314. For two adjacent 
steamers, use Water Pressure Regulator 
P/N 7000235.

1.  With the power off, place the unit on a 

sturdy, level surface.

2.  Ensure the line voltage corresponds to 

the stated voltage on the specification 
label and power cord warning tag.

3.  Connect the unit to the power supply.

3.  Turn the water valve on.
4.  Over a bucket, press and hold 

the white plastic tip on the Quick 
Disconnect Insert (Figure 1) until a 
good, steady water flow is noted (this 
will purge all air out of the line). 

5.  Release and note the pressure on the 

water pressure regulator gauge. It 
should read 20-25 psi. Adjust the pres-
sure by pulling the black knob upwards 
and turning it clockwise to increase 
or counter-clockwise to decrease the 
water pressure. Push the knob down to 
lock it in place.

NOTE: When adjusting the knob, you must 
relieve the existing pressure by pressing 
the plastic tip on the Quick Disconnect 
Insert for 3 seconds. This allows the newly 
set pressure to register on the gauge. 
Repeat this until the gauge reads 20–25 
psi. 

6.  Push the Quick Disconnect Insert into 

the fitting at the rear of the unit until 
it clicks into place (Figure 1).

Figure 1. Connecting Water Supply to DFW/DFWT/DFWF-200/250

Connect Quick

Disconnect 

Insert Here

Inlet Hose & Strainer

Assy. (Supplied)

Water Pressure Regulator

& Strainer Assy. (P/N 7000314)

Shut Off Valve
(Not Supplied)

Cold

Water

 Flow

Flexible Nylon Braided

1/4 " I.D. Tubing (Not Supplied)

Quick

Disconnect 

Insert

Worm

Clamp

CAUTION

Water pressure must not exceed 30 psi (2.1 
kg/cm2 or 207 kPa). Higher water pressures 
may cause poor performance or flooding. 
To reduce water pressure, install a water 
pressure regulator, and set water pressure to 
20–25 psi (1.4–1.7 kg/cm2 or 138–172 kPa). 

Содержание DFW series

Страница 1: ... 9100101 9100102 9100103 9100104 9100105 9100106 9100107 9100111 9100112 9100113 9100114 9100115 9100116 9100118 9100121 9100122 9100123 9100124 9100125 9100126 9100128 9100131 9100132 9100133 9100134 9100135 9100136 9100146 9100147 9100156 www ajantunes com POWER UP DOWN PROGRAM START STOP ...

Страница 2: ...e free operation WARRANTY INFORMATION Please read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the car rier immediately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the respon sibility of the purchaser and are not covered under warranty The warranty does not extend to Damages caused in shipmen...

Страница 3: ...ance Electrical ground is required on this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded If a chemical cleaner is used be sure it is safe to use on cast aluminum Observe all precautions and warnings on product label Inspection testing and repair of elec trical equipment should only be per formed by qualified service personnel This...

Страница 4: ...0 Volt DFWT 150 9100126 230 2800 12 2 50 60 CEE 7 7 16 Amp 250 Volt DFWT 150 9100128 230 2800 12 2 50 60 IEC 309 16 Amp 250 Volt DFWT 200 9100131 120 1800 15 50 60 NEMA 5 15P 15 Amp 120 Volt DFWT 200 9100132 120 1800 15 50 60 NEMA 5 20P 20 Amp 120 Volt DFWT 200 9100133 230 2800 12 2 50 60 CEE 7 7 16 Amp 250 Volt DFWT 250 9100134 120 1800 15 50 60 NEMA 5 15P 15 Amp 120 Volt DFWT 250 9100135 120 180...

Страница 5: ...odels require a direct cold water hookup A water inlet hose and strainer assembly Figure 1 is supplied Incoming water is controlled by a normally closed solenoid valve located inside the steamer s electrical housing 1 Turn off the water valve not supplied that provides water to the unit 2 Connect the 1 4 6 5 mm ID flexible tubing to the outlet side of the water pressure regulator and secure using ...

Страница 6: ...15 minutes To change any of these settings see the appropriate Operating Instructions for your specific unit OPERATING INSTRUCTIONS NON TIMER MODELS 1 Turn the power on Figure 2 2 Allow the unit to preheat for approxi mately 30 minutes NOTE Do NOT push the OPERATE button during warm up 3 Open the top cover and place the product to be steamed onto the trivet then close the cover 4 Press the OPERATE...

Страница 7: ...n release SHO will be displayed Item D Figure 4 6 Press and release the PROGRAM but ton and use the UP or DOWN ARROW buttons to change the SHO setting in seconds Item E Figure 4 NOTE 20 seconds is recommended 7 Press and release the PROGRAM but ton again and use the UP or DOWN ARROW buttons to change the SHO setting in minutes Item F Figure 4 NOTE 00 minutes is recommended Figure 4 Control Program...

Страница 8: ... and hold the PROGRAM and START STOP buttons simultaneously 3 Turn the unit on while holding the buttons Release the buttons when the unit stops beeping NOTE Repeat steps 1 through 3 if the unit still displays the ERR fault code 4 The display will now register 15 00 NOTE It is recommended that the SHO and H2O settings be adjusted to the recommended settings shown in the Programming section of this...

Страница 9: ...ollow the delimer manufacturer s instructions for proper mixture and use 2 Using a sponge or a dry towel remove the delimer solution from the genera tor surface and then rinse the surface with clean water To ensure proper steaming characteristics some calcium mineral deposits must be pres ent on the generator surface If during clean ing the surface does become free of calcium mineral deposits add ...

Страница 10: ... rear hinge bracket screws Figure 9 one turn only 2 Push down on the top cover heavily Figure 9 This ensures the gasket is seated squarely around the Generator While maintaining the downward pressure re tighten the screws WATER STRAINER DIRECT WATER HOOKUP MODELS The water strainer protects your equipment from any foreign debris in the water line that could damage the unit s solenoid causing the u...

Страница 11: ...ircuit Thermistor is inoperable Non Timer Models Only The unit s main electrical panel circuit breakers trips Damaged receptacle plug or cord or a loose connec tion or an internal component failure Turn power off allow unit to cool to room tempera ture and then restart the unit Contact your main tenance person or Authorized Service Agency if the condition repeats Circuit breaker is overloaded Wate...

Страница 12: ...alues as described in the Programming section of this manual Insufficient or excessive calcium mineral deposits on the Generator surface Verify that a thin layer of calcium mineral deposits is present on the Generator surface Refer to the Maintenance section of this manual Generator surface is bare The Generator surface must have a thin coating of calcium mineral deposits for proper steaming Refer...

Страница 13: ...ing the unit on a number of single shot cycles and then letting it rest If the unit still leaks disassemble the Solenoid Valve and clean out the plunger Reassemble the unit and test again If a leak is still present replace the Solenoid Valve Contact your maintenance person or Authorized Service Agency The Water Pump and or its Check Valves are clogged or damaged Verify that the filter is present i...

Страница 14: ... Lobster Tails 5 Frozen 8 oz ea 16 Rock Lobster Tails 4 10 oz ea 10 Rock Lobster Tails 4 Frozen 10 oz ea 20 Sea Scallops 1 lb 5 8 Shrimp Green Headless 20 1 oz ea 6 Shrimp Peeled Deveined 1 lb 5 6 Shrimp Peeled Deveined Frozen 1 lb 8 9 Turbot Steaks 3 8 oz ea 5 POULTRY Chicken 4 Quarter 10 oz ea 23 25 Chicken 2 Half 1 lb ea 25 Chicken Supreme 6 Frozen 30 Pillow Pack 4 oz ea Chicken or Turkey Roll ...

Страница 15: ... D PVC BRD 12 Long 1 4 2040150 Elbow Male Nylon 2 1 4 Barb x 3 8 NPT 5 0503615 Bracket Manifold Mtg 1 6 2190129 Nipple 1 4 NPT x 1 4 NPT 1 7 2090127 Strainer 1 4 FPT 1 8 2080118 Quick Disconnect 1 8 NPT 1 9 2190113 Manifold 1 10 2110160 Clamp Ear Med 4 11 2040151 Nipple HEx 3 8 x 1 4 NPT Nylon 1 12 2170114 Gauge Water Pressure 1 13 2170113 Regulator Pressure 1 1 10 3 9 2 4 5 13 11 12 6 7 8 1 05038...

Страница 16: ...7 33 33 41 42 43 44 57 58 67 67 67 67 68 69 70 70 70 71 72 74 53 Inset B 32 57 31 51 77 81 64 33 See Inset C See Inset B 9 8 34 35 36 37 39 40 54 55 59 64 70 73 75 79 74 Inset C Non Timer Models DFW DFWT 100 MAD EINUSA T3 T4 PCB 00 0 234 R13 C5 R6 R9 R1 R5 R2 U1 CR6 CR1 T1 R12 C4 R4 R15 C6 R10 R14 C1 VR1 C3 T2 R8 SER IAL NO R18 CR5 ANT UNE S R16 T6 T5 R11 CR4 CR2 8 34 35 36 38 39 55 56 59 64 70 73...

Страница 17: ...pring 3 Mfg 9100128 only 28 0020952 Hinge Beam 1 Mfg 9100128 only 29 0502722 Pivot Bracket 1 Mfg 9100128 only 31 0012546 Access Cover Assy 1 32 7000214 Diode Assy 1 33 7000849 Silicone Tube Kit 1 Includes 2 tubes 34 1000976 Label Front Panel 1 Non Timer Models only 1001036 Label Front Panel 1 Timer Models only 35 4010166 Operate Switch 1 36 4010151 Rocker Switch 120V 1 4010137 Rocker Switch 230V 1...

Страница 18: ...64 64 66 61 63 16 54 40 54 7 8 8 34 34 35 35 36 36 37 38 39 39 41 42 43 45 46 47 48 49 53 55 55 56 58 59 59 59 64 64 68 69 70 70 70 73 73 74 75 75 79 79 74 74 50 Inset B Inset C Timer Models DFW DFWT 250 Inset C Non Timer Models DFW DFWT 200 10 76 See Page 15 for Strainer Parts 52 40 See Inset C 31 81 64 See Inset B 9 ...

Страница 19: ...Tube Kit 1 Includes 2 tubes 34 1000976 Label Front Panel 1 Non Timer Models only 1001036 Label Front Panel 1 Timer Models only 35 4010166 Operate Switch 1 36 4010151 Rocker Switch 120V 1 4010137 Rocker Switch 230V 1 37 7000392 Control Board 1 Non Timer Models only 38 7000317 Control Board 1 Timer Models only 39 7000319 Transformer 1 40 7000652 Relay Solid State 1 41 7000135 Hi Limit Thermostat 1 4...

Страница 20: ...4 45 A B I L M P K 7 26 27 28 29 30 31 32 33 A G H I K 34 7 8 17 E D 10 B B 25 15 14 11 B 22 F 21 20 19 18 16 12 See Inset A See Inset B Inset B Timer Model only 5 6 42 N See Page 25 for Strainer Parts 41 9 See Page 5 8 35a 36 37 38a 44 A B I L M P K Inset A Non Timer Model Mfg No 9100147 40 43 40 39 ...

Страница 21: ...1 2000188 Outlet Tube 1 32 2040103 Male Connector 1 4 1 33 4040145 Solenoid 24 VAC 1 34 7000138 Quick Disconnect 1 Body Plate Kit 35 1001036 Front Panel Label 1 Timer Models Only 35a 1000976 Front Panel Label 1 Non Timer Models Mfg No 9100147 36 4010166 Operate Switch 1 37 4010137 Power Switch 1 38 7000317 Control Board 1 Timer Models Only 38a 7000392 Control Board 1 Non Timer Models Mfg No 910014...

Страница 22: ...AM WHT T6 T5 SOLENOID PUMP OR 120V 230V WHT BLK WHT BLK BLK MOMENTARY SWITCH T1 T2 T4 ORG BRN BRN BLU GND PUMP ONLY YEL RED T7 T3 2 1 3 4 BLU DIODE PUMP ONLY BLK 6 2 1 TRANSFORMER 4 5 8 10 18 GA AWM 105 C BLK BRN WHT BLU GRN GRN YEL UNLESS OTHERWISE SPECIFIED NOTE ALL WIRES TO BE 14 GA AWM 105 C HEATER THERMOSTAT HI LIMIT CONTROL THERMOCOUPLE 22 GA AWM 105 C S S RELAY BOARD WIRING DIAGRAM ...

Страница 23: ...RD WHT BLK WIRING DIAGRAM WHT THERMOSTAT HI LIMIT CONTROL TEMP T1 T2 MOMENTARY SWITCH SOLENOID PUMP OR 120V 230V T3 T4 WHT BLK WHT BLK BLK BRN ORG BLK BRN GND PUMP ONLY T5 T6 2 3 1 4 YEL RED PUMP ONLY DIODE BLK 18 GA AWM 105 C BLK BRN WHT BLU GRN GRN YEL UNLESS OTHERWISE SPECIFIED NOTE ALL WIRES TO BE 14 GA AWM 105 C HEATER S S RELAY THERMISTOR 22 GA AWM 105 C WIRING DIAGRAM continued ...

Страница 24: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service age...

Отзывы: