Display Cabinet vertiCal
8
P/N 1011068 Rev. D 08/10
TEMP
UP
TEMP
DOWN
TEMP
SCALE
F
C
O
O
Rear Door
Rear Door
figure 3. controls
figure 2. rear Doors
Operation
the DcV-200 has an adjustable temperature range of
150°f to 165°f (66°c to 74°c).
1. Open the Rear Door(s) and place the serving
table pan(s) into the unit.
2. Load the pans with food product using tongs or
similar utensils.
3. Keep door(s) closed when not removing or add
-
ing food product.
programming
aDJUst tHe setpOInt temperatUre
the setpoint temperature is the desired cabinet tem-
perature setting. the default setpoint temperature is
150°f (66°c). When the
temp Up
button is pressed
and held (and provided that the unit is up to tempera-
ture), the actual cabinet temperature is displayed.
When the button is released, the setpoint temperature
is displayed.
1. turn the power on. the display will flash “
lO
” to
indicate that the unit is heating up. after 25-35
minutes (when the unit is up to temperature), the
display will show the setpoint temperature.
2. Press and hold the
temp Up
and
temp Down
buttons (figure 3) until the display begins to flash.
3. Press the
temp Up
or
temp Down
buttons to
raise or lower the setpoint temperature. Release
when the display shows the desired temperature.
cHanGe temperatUre DIsplay
1. Press and hold the
temp scale
button
(figure 3) for 2-3 seconds to change the
display from fahrenheit to celsius.
OperatInG & prOGrammInG