Roundup DCV-200 Скачать руководство пользователя страница 8

Display Cabinet vertiCal

8

P/N 1011068 Rev. D 08/10

TEMP

UP

TEMP

DOWN

TEMP

SCALE

F

C

O

O

Rear Door

Rear Door

figure 3. controls

figure 2. rear Doors

Operation

the DcV-200 has an adjustable temperature range of 

150°f to 165°f (66°c to 74°c).
  1.  Open the Rear Door(s) and place the serving 

table pan(s) into the unit.

  2.  Load the pans with food product using tongs or 

similar utensils.

  3.  Keep door(s) closed when not removing or add

-

ing food product.

programming

aDJUst tHe setpOInt temperatUre

the setpoint temperature is the desired cabinet tem-

perature setting. the default setpoint temperature is 

150°f (66°c). When the 

temp Up

 button is pressed 

and held (and provided that the unit is up to tempera-

ture), the actual cabinet temperature is displayed.  

When the button is released, the setpoint temperature 

is displayed.
  1.  turn the power on. the display will flash “

lO

” to 

indicate that the unit is heating up.  after 25-35 

minutes (when the unit is up to temperature), the 

display will show the setpoint temperature.

  2.  Press and hold the 

temp Up 

and 

temp Down 

buttons (figure 3) until the display begins to flash.

  3.  Press the 

temp Up 

or 

temp Down 

buttons to 

raise or lower the setpoint temperature. Release 

when the display shows the desired temperature.

cHanGe temperatUre DIsplay

  1.  Press and hold the 

temp scale 

button  

(figure 3) for 2-3 seconds to change the  

display from fahrenheit to celsius.

OperatInG & prOGrammInG

Содержание DCV-200

Страница 1: ...P N 1011068 Rev D 08 10 Display Cabinet Vertical Model DCV 200 Owner s Manual Manufacturing Numbers 9500560 A S D L I S T E CM O I N NIT A T C T I S L US E D D L I S T E C US INTERTEK...

Страница 2: ...this manual If the unit arrives damaged contact the carrier immediately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility o...

Страница 3: ...u have trouble locating your local Authorized Service Agency Service Technical Assistance If you experience any problems with the installation or operation of your unit contact your local Authorized S...

Страница 4: ...eparate electrical lines pro tected by fuses or a circuit breaker of the proper rating Electrical ground is required on this unit Do NOT modify the power supply cord plug If it does not fit the outlet...

Страница 5: ...for glass cleaning only If removed the glass should be placed on a flat surface cov ered with a soft cloth Use a clean soft cloth when cleaning the glass Do NOT use paper towels Use light pressure whe...

Страница 6: ...olt Non locking Model Mfg No Width A Depth B Height C Operating Weight DCV 200CT 9500560 30 11 16 779 mm 29 3 4 756 mm 30 1 4 768 mm 141 lbs 64 kg Capacities DCV 200 Two 4 102 mm deep full size steam...

Страница 7: ...rvice pay attention to the following guidelines Make sure power to the unit is off and the unit is at room temperature Do NOT block or cover any openings on the unit Do NOT immerse cord or plug in wat...

Страница 8: ...66 C When the Temp Up button is pressed and held and provided that the unit is up to tempera ture the actual cabinet temperature is displayed When the button is released the Setpoint temperature is di...

Страница 9: ...cord and allow the unit to cool to room temperature 2 Lift the outer door and pull the bottom edge out Repeat with inner door 3 Carefully place new inner door in guide followed by the outer door Cauti...

Страница 10: ...over and carefully slide it down onto the top of the unit Caution Front Glass Panel replacement should be per formed by two people to prevent damage to the glass Slide Top Cover Up and Back Lift and R...

Страница 11: ...ll display it on the console In this example the Setpoint temperature is 150 F 66 C HI flashes if the actual cabinet temperature exceeds the Setpoint temperature or if the thermistor has shorted NOTE...

Страница 12: ...r s Loose burnt broken wiring in circuit Display flashes HI and the cabinet does not heat up Inoperable Thermistor Contact your maintenance person or Authorized Service Agency for service Inoperable C...

Страница 13: ...13 Display Cabinet Vertical P N 1011068 Rev D 08 10 Wiring Diagrams...

Страница 14: ...6 9 55 58 66 4 56 10 28 30 32 77 65 33 34 35 36 39 40 55 63 58 64 81 37 44 25 31 43 24 63 42 80 47 38 7 8 59 48 49 11 13 12 16 61 61 22 23 21 17 19 19 18 17 26 27 27 28 46 29 50 62 52 53 54 78 63 51 4...

Страница 15: ...00320 Lower Track Back Door 1 40 0024636 Flange Back Door Bottom Weldment 1 41 7000136 Terminal Block 3 Pole Kit 1 42 0505904 Channel Wire 1 43 0021624 Support Right Side Weldment 1 44 0021623 Support...

Страница 16: ...Light Bulbs Air Bulb Actuators Rubber Seals Rubber Feet Teflon Egg Rings Teflon Dampers Teflon Curtains Damper Support Springs This warranty does not cover damage to the Load Cell or Load Cell Assemb...

Отзывы: