4.3.2
Installation Steps
1)
Assemble the positioner with the bracket made in previous step by fastening the bolts (M8 x 1.25P).
Fig. 4-3: Attaching positioner to bracket
Fig. 4-4: Attaching the bracket to actuator yoke
2)
Attach the positioner with the bracket to the actuator yoke
–
DO NOT TIGHTEN THE BRACKET COMPLETELY.
3)
Connect connection bar to the actuator clamp. The hole gap on the feedback lever is 6.5 mm so
the connection bar’s outer diameter should be less than 6 mm.