4.3.2
Installation Steps
1)
Assemble the positioner with the bracket made in previous step by fastening the bolts (M8 x 1.25P).
Fig. 4-3: Attaching the positioner to the bracket
Fig. 4-4: Attaching the bracket to actuator yoke
2)
Attach the positioner with the bracket to the actuator yoke
–
DO NOT TIGHTEN THE BRACKET COMPLETELY.
3)
Connect connection bar to the actuator clamp. The hole gap on the feedback lever is 6.5 mm so
the connection bar’s outer diameter should be less than 6 mm.
4)
Connect an air-filter regulator to the actuator temporarily. Supply enough air pressure to the
actuator in order to position the valve stroke at 50 % of the total stroke.
Fig. 4-5: Positioning the valve at 50 % of the total stroke