background image

Gearbox ILG/D 

 

manual 

Rotork Gears bv 

7

 

 

Figure 5 : ILG/D gearbox  

 
3.

 

To close the valve, turn the handwheel clockwise.  

4.

 

Stop turning until the required valveposition is achieved. The number of turns needed from  totally open to 
totally close the valve is in table 3. 

5.

 

When the valve can not be totally opened (or closed), first the cause has to be detected and solved.  

6.

 

In case of malfunction of the gearbox, this one has to be replaced (see chapter installation for 
dismounting). Return the gearbox to your supplier for repair. 

7.

 

When you do the repair in house, all replacement parts must be obtained from the manufacturer to assure 
proper operation of the gearbox. 

8.

 

When the fault is repaired, turn the handwheel until blocked. 

9.

 

Declutch the gearbox:   

i.

 

Pull de knob outwards (1).  

ii.

 

Turn the handle clockwise (4) and release the knob. Continue turning the handle  until the knob falls 
into its locking position (3). 

10.

 

In case of opening the valve, follow procedure described under point 2 to 5. Except point 3: to open the 
valve, turn the handwheel counter-clockwise. 

Содержание ILG/D 100

Страница 1: ...MANUAL FOR INSTALLATION AND OPERATING for gearbox model ILG D 04 2011...

Страница 2: ...x ILG D manual Rotork Gears bv 2 1 Preface 3 1 1 Technical data 3 1 2 Handling and safety precautions 3 2 Installation mounting to the valve 4 3 Adjustment of the stopscrews 5 4 Operating 6 5 Maintena...

Страница 3: ...F07 26 250 ILG D 600 F07 F10 F12 F07 F10 F14 60 750 ILG D 900 F10 F12 F14 F10 F12 F14 125 1450 ILG D 1500 F12 F14 F16 F10 F12 F14 F16 160 2485 ILG D 2400 F14 F16 F12 F14 F16 188 3390 ILG D 5000 F16 F2...

Страница 4: ...allowable input and output torque refer to table 1 This manual describes the installation of the gearbox and its parts The intention of the ILG D gearbox is to operate the valve in case of a failing a...

Страница 5: ...er 3 3 Adjustment of the stopscrews The gearbox is mounted on top of the valve see installation 1 In case of a pneumatic actuator be sure the actuator depressurised 2 Put the gearbox in the manual mod...

Страница 6: ...xample from an ILG D gearbox 4 Operating The ILG D is a manual declutchable override quarter turn gearbox for double acting pneumatic or electric actuators For maximum allowable input and outputtorque...

Страница 7: ...laced see chapter installation for dismounting Return the gearbox to your supplier for repair 7 When you do the repair in house all replacement parts must be obtained from the manufacturer to assure p...

Страница 8: ...of turns to open close 5 Maintenance Under normal conditions the gearbox is maintenance free The Rotork Gears ILG D gearboxes can be used at ambient temperatures from 20 to 120 C Other temperature ran...

Отзывы: