1. 

Preface 

 
 
Rotork Gears BV produces gearboxes of different types and sizes. The model ILG/D is a declutchable override 
quarter turn gearbox for double acting pneumatic or electric actuators. The ILG/D is intended for manual 
operation of the valve, in case of failure of the automatic actuator system. 
 
NB. This manual is only for the standard ILG/D gearboxes of Rotork Gears BV. For special versions, the values 
can differ. 
 
Rotork Gears BV is not responsible for any damage caused by incorrect use of the gearbox. 
 
 

1.1 

Technical data 

 

Specifications 

The maximum allowable input- and output torque are listed in table 1. 

Gearbox 

Connection to 

actuator 

connection to 

valve 

Max. Torque [Nm] 

type 

ISO 5211 

ISO 5211/1 

Input 

Output 

ILG/D 100 

F05-F07 

F05-F07 

13 

150 

ILG/D 200 

F05-F07 

F05-F07 

26 

250 

ILG/D 600 

F07-F10-F12 

F07-F10-F14 

60 

750 

ILG/D 900 

F10-F12-F14 

F10-F12-F14 

125 

1450 

ILG/D 1500 

F12-F14-F16 

F10-F12-F14-F16 

160 

2485 

ILG/D 2400 

F14-F16 

F12-F14-F16 

188 

3390 

ILG/D 5000 

F16-F25 

F16-F25 

298 

7450 

ILG/D 8000PR3 

F16-F25 

F16-F25 

120 

8135 

ILG/D 16000PR6 

F25-F30 

F25-F30 

140 

17000 

ILG/D 232-10 

F07 

F07-F10-F12 

25 

250 

table 1 :  connection data of  gearboxes 

 

1.2 

Handling and safety precautions 

 
Be sure to read and understand this manual before installation and use of our ILG/D-gearbox.  
 

Storage 

The gearboxes need to be stored in a safe way to avoid accidents.  Also avoid storage in areas subjected to high 
temperature extremes and /or areas subjected to  large amounts of humidity and dust. 
 

Handling 

Never drop the gearbox or subject it to strong impact.  
 

Correct use 

Before installation , be sure the gearbox will NOT be overloaded during normal use. This means the gearbox 
must be suited for the valve and actuator to which it is mounted. For checking, see table 1 for the maximum 
allowable torque. 
 
 

Содержание ILG/D 100

Страница 1: ...MANUAL FOR INSTALLATION AND OPERATING for gearbox model ILG D 04 2011...

Страница 2: ...x ILG D manual Rotork Gears bv 2 1 Preface 3 1 1 Technical data 3 1 2 Handling and safety precautions 3 2 Installation mounting to the valve 4 3 Adjustment of the stopscrews 5 4 Operating 6 5 Maintena...

Страница 3: ...F07 26 250 ILG D 600 F07 F10 F12 F07 F10 F14 60 750 ILG D 900 F10 F12 F14 F10 F12 F14 125 1450 ILG D 1500 F12 F14 F16 F10 F12 F14 F16 160 2485 ILG D 2400 F14 F16 F12 F14 F16 188 3390 ILG D 5000 F16 F2...

Страница 4: ...allowable input and output torque refer to table 1 This manual describes the installation of the gearbox and its parts The intention of the ILG D gearbox is to operate the valve in case of a failing a...

Страница 5: ...er 3 3 Adjustment of the stopscrews The gearbox is mounted on top of the valve see installation 1 In case of a pneumatic actuator be sure the actuator depressurised 2 Put the gearbox in the manual mod...

Страница 6: ...xample from an ILG D gearbox 4 Operating The ILG D is a manual declutchable override quarter turn gearbox for double acting pneumatic or electric actuators For maximum allowable input and outputtorque...

Страница 7: ...laced see chapter installation for dismounting Return the gearbox to your supplier for repair 7 When you do the repair in house all replacement parts must be obtained from the manufacturer to assure p...

Страница 8: ...of turns to open close 5 Maintenance Under normal conditions the gearbox is maintenance free The Rotork Gears ILG D gearboxes can be used at ambient temperatures from 20 to 120 C Other temperature ran...

Отзывы: