background image

21 

 

 

 

Maintenance 

 

Periodic lubrication of Thrust Rod 

After 20,000 operating cycles, re-lubricate the actuator thrust rod.   

Make sure it is safe to depressurize the system.   Move the setup knob to the Operate Pulse mode and 
pressing the Jog Dn button, retract the thrust rod to its most retracted position (Zero output pressure 
from the pressure regulator).  To expose the thrust rod remove the four bolts that attaches the pressure 
regulator to the actuator housing.  Remove the pressure regulator and Thrust Rod Cap exposing the 
Thrust Rod.  With the setup knob to the Operate Pulse mode and pressing the Jog Up button, extend the 
thrust rod to its most extended opposition.  Apply Dow Corning G-n lubricant to the exposed thrust rod 
thread.  Using the Jog Dn button, retract the thrust rod to its most retracted position.  Re-install the 
thrust rod cap and pressure regulator. 

 

 

 

 

 

 

 

 

 

 

Caution 

 

Shutting off Motor Set Pressure Regulator and disconnecting associated equipment can cause 
dangerous system conditions to exist.  Ensure the System is properly prepared for maintenance to 
be performed on the unit before taking it out of service. 

Содержание PAX1

Страница 1: ...well In analog control mode the unit is fail freeze upon loss of either control signals The actuator features UP and DOWN push buttons under the cover to facilitate commissioning and to permit local c...

Страница 2: ...uipment damage serious injury or death Hazardous Area Ratings Flameproof Factory Mutual CSA Class I Division 1 Groups ABCD T6 T5 Class I Division 1 Groups B C D T6 T5 Class II III Division 1 Groups EF...

Страница 3: ...tart with the third thread back and work away from the end of the fitting to avoid the possibility of contaminating the regulator Install the regulator in the air line The inlet and outlet connections...

Страница 4: ...elays require ferrules supplied to provide proper insulation for the high voltage AC connections Power Supply Sizing For 12 vdc operation the recommended power supply should have 2 amp capacity For 24...

Страница 5: ...p Rtn MTR ENAB DN V mA V mA 1 2 3 4 5 6 7 8 9 10 11 12 UP PWR LOOP SUPPLY Figure 1 SW2 Isolation Switch Set to Isolate FEEDBACK Switch set to PULSE Internal connection of NO ISOLATE switch Set to ISOL...

Страница 6: ...A 1 2 3 4 5 6 7 8 9 10 11 12 PWR Figure 3 FEEDBACK 4 20 mA CONTROLLER Set switch to ANALOG SW1 Set switch to 4 20 mA Lp Pwr DN UP MTR ENAB V mA V mA 1 2 3 4 5 6 7 8 9 10 11 12 PWR Figure 4 FEEDBACK 1...

Страница 7: ...3 4 5 6 7 8 9 10 11 12 PWR Figure 5 FEEDBACK POWER SUPPLY MILLIAMMETER LOOP SUPPLY CLOSED SWITCH DISABLES MOTOR Lp Pwr DN UP MTR ENAB V mA V mA 1 2 3 4 5 6 7 8 9 10 11 12 PWR Figure 6 FEEDBACK POWER...

Страница 8: ...parate external power source SW2 NO The Pulse control input circuit is connected to the DC power supply providing power to the unit Push button switches UP Moves the pressure regulator setpoint to a h...

Страница 9: ...through the hole in the top PCA cover near the SET button Turning the motor clockwise increases pressure counter clockwise decreases pressure Take care not to drive the actuator into its mechanical s...

Страница 10: ...rol current 2 7 Move the SETUP SWITCH to the TRAVEL LIMIT HI setting 2 8 Using the UP and DN buttons under the cover adjust the output pressure to the highest desired pressure 2 9 Apply the desired co...

Страница 11: ...o the ALARM SWITCH HI setting 4 5 Using the UP and DN buttons adjust the pressure regulator to its HI ALARM pressure 4 6 Press the SET button and wait for the ALARM HI LED to turn from Green then red...

Страница 12: ...d 6 2 Turn the adjustment clockwise to increase the output pressure and counter clockwise to decrease the output pressure 6 3 Take care when manually adjusting the actuator as you can damage the unit...

Страница 13: ...AUST 2X M8 MOUNTING HOLES 13 71 348 1 2 69 68 3 1 25 31 8 2 5 63 6 9 37 238 0 3 66 93 0 5 12 130 0 O 0 35 9 0 2X BRACKET MOUNTING HOLES 5 87 149 0 22595 1 MOUNTING BRACKET SOLD SEPARATELY 1 4 18 NPTF...

Страница 14: ...87 0 1 25 31 8 2 5 63 6 9 14 232 2 O 5 25 133 4 2X M5 MOUNTING HOLES 14 18 NPTF GAGE PORT 1 2 14 NPTF 1 2 14 BSPT 1 2 14 BSPP 3 4 14 NPTF 3 4 14 BSPT 3 4 14 BSPP INLET OUTLET 1 2 14 NPTF OR 3 4 14 NPT...

Страница 15: ...9 284 1 15 26 387 7 8 87 225 3 1 4 18 NPTF GAGE 1 4 18 NPTF OR 1 4 19 BSPT EXHAUST 3 75 95 2 BRACKET 1 2 14 NPTF OR 3 4 14 NPTF CONDUIT PORT M5 GROUND SCREW HOLE 1 18 30 0 1 2 14 NPTF 1 2 14 BSPT 1 2...

Страница 16: ...7 10 3 261 7 12 81 325 4 1 18 30 0 0 75 19 0 3 07 78 0 6 07 154 2 O 6 93 175 9 M5 SAFETY SCREW HOLE 1 25 31 8 2 5 63 6 2X M8 x 1 25 MOUNTING HOLES O 1 99 50 5 O 2 12 53 8 8 47 215 2 1 4 18 NPTF INLET...

Страница 17: ...07 78 0 1 00 25 3 3 61 91 6 6 157 156 4 11 4 288 4 1 18 30 0 13 86 352 0 6 07 154 2 O 6 93 175 9 2X M8 X 1 25 MOUNTING HOLES 1 4 NPTF OR BSPT INLET OUTLET 1 2 14 NPTF OR 3 4 14 NPTF CONDUIT PORT M5 SA...

Страница 18: ...3 6 2X M8 x 1 25 MOUNTING HOLES 3 07 78 0 0 53 13 5 1 4 OR 3 8 NPT OR BSPT INLET OUTLET 4 923 125 0 10 119 257 0 12 625 320 7 1 2 14 NPTF OR 3 4 14 NPTF CONDUIT PORT M5 SAFETY SCREW 1 18 30 0 6 07 154...

Страница 19: ...e 11 30VDC Power Consumption 22 watts max 1 watt standby Actuation Electrical Analog Actuation Control 4 20 mA 1500V optically isolated from power supply Switch for common power supply 1 5VDC non isol...

Страница 20: ...eed Multi turn pot 1 2 60 mm min Limit adjustments Push button switch to accept current thrust rod position for 2 End of Travel limit 2 Alarm Switch and Analog Feedback Calibration Setup Switch 8 posi...

Страница 21: ...Remove the pressure regulator and Thrust Rod Cap exposing the Thrust Rod With the setup knob to the Operate Pulse mode and pressing the Jog Up button extend the thrust rod to its most extended opposi...

Страница 22: ...tor Assembly Thrust Rod Thrust Rod Cap Pressure Regulator Mounting Bolts Pressure Regulator Mounting Plate Pressure Regulator Figure 16 OM 100PAX1R REV B 06 18 Actuator O Ring O Ring O Ring Contact Fa...

Отзывы: