![ROTORCOMP NK 31 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/rotorcomp/nk-31/nk-31_installation-and-operating-manual_1491742032.webp)
6.2
[en] 02/2014
Installation and operating manual - NK 31
ROTORCOMP VERDICHTER
6.4 Recommissioning
screw compressor system
Screw compressor systems switched off, shut
-
down or stored for longer than three months
cannot be put into operation again until after the
following measures have been carried out:
– Rotate the screw compressor in the direction
of rotation several times by hand.
– With the screw compressor system at a com
-
plete stop, pour approx. 0.2 liters of oil (same
oil type as in oil separator tank) into the filler
neck after removing the intake filter. To do this,
push down the valve plate and pour the oil
directly into the intake opening.
– Rotate the screw compressor again in the
direction of rotation several times by hand.
– Check the oil level in the separator tank and
top up if necessary (see chapter
7
„Mainte-
nance“).
– Test the running check function for the screw
compressor system for at least 15 minutes.
Warning
The system may not be started with the feed
chamber completely filled. There is a danger of
considerable damage.