18
ENGLISH
3.2.4 Putting out of operation
Switch off heating element and pull power plug from the socket.
For safty storage and transportation the machine can be kept in a crate (no. 55555).
The hotplate must be cooled off!
3.3
General requirements
Because weather and environmental influences have a decisive impact on welding, the corre-
sponding specifications in the DVS guidelines 2207 Part 1, 11 and 15 must be observed uncon-
ditionally. Outside Germany the corresponding national guidelines shall apply.
(The welding work must be monitored constantly and carefully!)
4
Care and Maintenance
Check the heating arbour and jack for signs of damage. If they are damaged they must be re-
coated. Material residue is to be removed with non-fibrous paper and methylated spirits.
The heating element may only be supplied with the voltage specified on the type plate.
If the mains cable is damaged it must be replaced with a special cable H 05 RR-F.
Do not use any cleaning products which contain solvents to clean the machine since they may
damage the plastic parts.
It is recommendable to have repairs done only by a service workshop or by
the manufacturer!
5
Accessories
Accessory Name
ROTHENBERGER Part Number
Butt Fusion Set ROWELD P125 (= 2 pcs.)
55536
Cylinder head screw DIN912 M6x40
L81357
Table Clamp
55524
Floor Stand
55539
Tighten Pin
55549
Allen key DIN 911 SW 5
321215
Steel Case
55555
Spare parts
www.rothenberger.com
6
Customer service
The ROTHENBERGER service locations are available to help you (see listing in catalog or on-
line) and replacement parts and service are also available through these same service locations.
Order your accessories and spare parts from your specialist retailer or using Ro online:
Phone:
+ 49 (0) 61 95 / 800
– 8200
Fax:
+ 49 (0) 61 95 / 800
– 7491
Email:
www.rothenberger.com
Содержание ROWELD P 125
Страница 31: ...29 16 Schaltplan Wiring diagram ...
Страница 35: ...NOTES 33 ...