ENGLISH
13
Always keep the connecting cable away from the sphere of action of the equipment. Always
guide the cable away from the equipment to the rear.
Please look out for electric cables, gas and water pipes when working on the wall, ceiling or
floor.
Protect the equipment against splash water. Do not work over head!
2
Technical Data
Nominal acceptance power ......... 800 W
1. Gear
2. Gear
Speed ......................................... 4200 min
-1
............. 7500 min
-1
Drilling diameter ..........................
Ø
25 – 67 mm .......
Ø
6 – 25 mm
Drilling range ..............................
Masonry
Ø
40 x 400 mm
Concrete
Ø
35 x 150 mm
Tile
Ø
6 – 67 mm
Tool fitting ................................... Quick change adapter with G 1/2" fitting
Weight ........................................ approx. 4,0 kg
Drill bit types ...............................
High Speed Plus, No. FF44806 – FF44868
SPEED STAR DX, No. FF00610 – FF00665
Speed electronic .......................... Yes
Noise pressure level (L
pA
) ........... 91 dB (A) ¦ K
pA
3 dB (A)
Sound power level (L
WA
) ............. 102 dB (A) ¦ K
WA
3 dB (A)
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 62841-1.
Vibration total value ................................
2,6 m/s
2
¦ K= 1,5m/s
2
The Vibration Total Value quoted in these instructions and the quoted noise emission values
were measured according to standardized measurement procedures and can be used to com-
pare one electric power tool with another. They can also be used to make an initial estimate of
the loading.
The quoted vibration and noise emissions can vary during actual use of the electric
power tool dependent on the way in which the electric power tool is used, in particular
what type of workpiece is being processed.
Establish additional safety measures to protect the operator which are based upon an
estimate of the vibration loading during the actual usage conditions (in doing so taking
account of parts of the operating cycle, for example times in which the electric power
tool is switched and those in which it is switched on but not running under load).
3
Power connection
Connect only to the single-phase alternating current indicated on the rating plate. Connect only
to sockets with protective contacts. The machine must be operated only through a ground fault
circuit with max. 10 - 30 mA rated leakage current.
Always perform the operational test before starting up the device. If there is a repeated failure,
have the connected device inspected.
Please keep in mind that this device cannot replace fundamental safety precautions. To prevent
life-threatening hazards, be sure to use electrical devices only as intended.
Reliable personal protection against electric shock. Fault currents are recognized in a fraction of
a second, and the current supply is immediately interrupted. The risk to humans and animals is
drastically reduced.
- Never use the electric tool without a PRCD.