16
ENGLISH
4x 5x red
Automatic switch-off (non-use / continuous operation)
6x red
Pressure sensor fault (contact specialist dealer)
7x red
Overcurrent / Short circuit
3x yellow
Set pressure not achieved
5.4
Commissioning
(B)
Screw hose onto air chamber.
Screw hose onto trigger valve.
Screw spray tube onto trigger valve.
Push in battery.
5.5
Fill tank
(C)
Check charge status on the battery!
Always use tank strainer fill in 2/3 of the amount of water.
Add liquid concentrate.
Powder must have dissolved completely!
Fill up with water.
Check gasket ring. Close tank.
Only use the amount of substance required.
Observe manufacturers mixing instructions.
5.6
Operating
(D)
Set pressure.
Check charging condition.
Wait until the pump switches off.
Spray
The integrated pressure sensor regulates the pump speed and switches the pump on and off.
5.7
Nozzle capacity
(E)
Spraying - 0 turn
Jet - 2 turns
5.8
Shut-down
(F)
Dispose in a correct way of residue and according to the manufacturer’s indications.
Empty, rinse with clean water.
Set max. Pressure, spray until no more liquid comes out.
Nozzle setting: Jet.
Fill with clear water, switch on the device (max. pressure), spray until no more liquid comes
out.
Clean nozzle.
Do not use hard objects.
Do not blow through with your mouth: risk of poisoning!
Always store tank empty, open and protected from frost.
If not in use for a longer period of time: store the fully charged battery separately from the appli-
ance.