18
GB
DC Current:
AC Current measurement:
Range
Accuracy:
200 µA / 2.000 µA
± 2.0% ± 8 digits
20 mA / 200 mA
Range
Accuracy:
200 µA / 2.000 µA
± 2.5% ± 10 digits
20 mA / 200 mA
Fuse:
0.2 A/250 V fast-acting
Maximum current:
200 mA
Fuse:
0.2 A/250 V fast-acting
Frequency range:
50 Hz - 400 Hz
Maximum current:
200 mA
Display:
RMS of the sine wave
SYMBOLS ON THE DISPLAY
1. Auto-range active
2. Testing diodes
3. Continuity check with alarm
4. Measurement saved
5. Battery status symbol
6. AC Voltage
7. DC Voltage:
8. Polarity indicator:
9. Result
10. Unit
1
4
P1
P3
BAT
2
3
4
5
9
10
6
7
8
1
Resistance measurements:
Range
Accuracy
200 Ω
± 0,8% ± 5 digits
2.000 kΩ, 200 kΩ, 20 kΩ
± 1,2% ± 5 digits
2.000 MΩ
± 5,0% ± 5 digits
20 MΩ
± 10% ± 5 digits
1500000806_Anleitung_D,GB,F,CZ,H,I,SLO.indb 18
15.07.13 12:53