3
x
Assembly
10
FA ROTEX Solaris flat roof - 05/2007
3.2
Assembly of flat roof trestle
Required tool:
– Hexagon socket key SW13 or ratchet with corresponding socket key insert
– Open-ended spanner SW13
– Saw
– Water level
– Yard stick
Raising anchorage weights against wind uplift
• Lay out sufficient concrete slabs (not included in the scope of delivery) as loading material on the flat roof near the installation
location for the flat roof trestle (for required total weight see Tab. 3-3).
3.2.1 Installing basic package
Collector V26A — basic package FD260 for 2 collectors
Collector H26A — basic package FD200H for 1 collector
1.
Level collector field and mark out the installation location.
– A defined roof area is required per collector:
V26A: 2.00 m x 1.37 m,
H26A: 2.13 m x 1.27 m.
Overall dimensions of the collector field (according to Fig 3-1 and Fig 3-2) are summarised in Tab. 3-1.
– Erection of the collector field to the midday sun (to the northern hemisphere in a southward direction, to the southern
hemisphere in a northward direction).
2.
Locate the setting angle for the collector field. As illustrated in Tab. 3-2
, there are 7 possibilities in the range of 32° to 56°.
Use standard concrete slabs e.g. lawn marginal tiles of 1 m long.
In setting angle of 32° to 48°, all support angles of the flat roof trestle must be cut to length according to
Tab. 3-2 (Fig 3-4 and Fig 3-5). Length variation of support angles for angles 52° and 56° is not necessary.
Fig. 3-4
Cutting support angle to length (V26A)
Fig. 3-5
Cutting support angle to length (H26A)