1
x
Safety
7
FA ROTEX SC+HYC - 10/2009
Sanitary connection
With sanitary connection, the following must be observed
•
EN 1717 -
Protection of domestic water from contamination in domestic water installations and general
requirements concerning safety equipment for the prevention of domestic water contamination
by back-flow
•
EN 806 - Technical regulations for domestic water installations (TRWI)
•
and, in addition, the country-specific legal stipulations.
•
During operation of the ROTEX Sanicube / HybridCube, the storage tank temperature may exceed 60 °C, particularly when
solar power is used. Therefore, some form of scalding protection needs to be included when you install the system (hot water
mixing device, e. g.VTA32
15 60 16).
•
Use a pressure reducer if the cold water connection pressure >6 bar.
Operation
•
Operate ROTEX Sanicube / HybridCube only with storage tanks filled up to overflow edges.
•
Operate the ROTEX Sanicube / HybridCube only with a set pressure reducer (max. 6 bar).
Instructing the user/owner
•
Before you hand over the heating system and the hot water storage tank, explain to the owner how he/she can operate and
check the heating system.
•
Document the hand-over by filling in and signing the checklist in Chapter 4 „Commissioning“, together with the operator.