6
x
Technical data
28
FA ROTEX SC+HYC - 10/2009
6.1.2
HybridCube (HYC)
HYC 343/19/0
HYC 544/19/0
HYC 544/32/0
Basic data
Unit
Total storage capacity
litres
300
500
500
Empty weight
kg
59
86
92
Total weight when full
kg
359
586
592
Dimensions (L x W x H) including installed switching unit from
E-PAC M
cm
59.5 x 61.5 x 159
79 x 79 x 159
79 x 79 x 159
Maximum permissible storage water temperature
°C
85
85
85
Heat consumption at stand-by and at 60 °C
kWh/24h
1.3
1.4
1.4
Domestic hot water (stainless steel 1.4404)
Drinking water capacity
litres
27.8
28.4
28.4
Maximum operating pressure
bar
6
6
6
Domestic water heat exchanger surface
m
2
5.7
5.9
5.9
Average specific heat capacity
W/K
2795
2860
2860
Storage tank charging heat exchanger (stainless steel 1.4404)
Water capacity heat exchanger
litres
12.3
9.5
17.4
Heat exchanger surface area
m
2
2.5
2.0
3.7
Average specific heat capacity
W/K
1235
1960
1810
Solar heating backup (stainless steel 1.4404)
Water capacity heat exchanger
—
4.8
4.8
Heat exchanger surface area
m
2
—
1
1
Average specific heat capacity
W/K
—
310
310
Thermal output data
Volume of hot water without reheating at draw-off rate (8 l/min
3)
/12
l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 50 °C)
l/min
174
3)
/ 139
4)
338
3)
/ 272
4)
338
3)
/ 272
4)
Volume of hot water without reheating at draw-off rate (8 l/min
3)
/12
l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 60 °C)
litres
270
3)
/ 260
4)
527
3)
/ 468
4)
527
3)
/ 468
4)
Volume of hot water without reheating at draw-off rate (8 l/min
3)
/12
l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 65 °C)
litres
322
3)
/ 302
4)
614
3)
/ 560
4)
614
3)
/ 560
4)
Reheat time (Wh) with a draw-off volume (bath tub: 140 l
5)
/ shower:
90 l
6)
)
(T
KW
=10 °C / T
WW
=40 °C / T
SP
=50 °C)
Min.
45
5)
/ 30
6)
45
5)
/ 30
6)
25
5)
/ 17
6)