3 Operation

Operation manual

3

RBLQ+07CAV3
ROTEX HPSU low temperature monobloc
4P417250-1 – 2015.08

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Control box RKCB07CAV3

c

Domestic hot water (DHW) tank

d

User interface connected to the control box

e

User interface in the living room, used as room thermostat

f

Underfloor heating

g

Heat pump convectors or fan coil units

h

Option box RK2CB07CAV3

3

Operation

3.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating/cooling
control

How to control space heating/cooling:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches between home pages (when you are on a home

page).

▪ Goes to the default home page (when you are in the menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages.
Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens  the  menu  structure  (when  you  are  on  a  home

page).

▪ Goes  up  a  level  (when  you  are  navigating  through  the

menu structure).

▪ Goes back 1 step (example: when you are programming a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or

between  displaying  actual  and  offset  values  (if  applicable)
on the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Button lock mode and/or function lock mode is active.

An external heat source is active. 

Example: 

Gas

burner.

The disinfection mode is active.

Содержание RBLQ05CAV3

Страница 1: ...Operation manual ROTEX HPSU low temperature monobloc English Operation manual ROTEX HPSU low temperature monobloc RBLQ05CAV3 RBLQ07CAV3 RDLQ05CAV3 RDLQ07CAV3...

Страница 2: ...ion carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has f...

Страница 3: ...up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on...

Страница 4: ...oor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switch...

Страница 5: ...t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in schedule...

Страница 6: ...chedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for...

Страница 7: ...es Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tem...

Страница 8: ...he risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happe...

Страница 9: ...of domestic hot water because of unusual high consumption If you immediately need domestic hot water activate the DHW tank booster mode However this consumes extra energy If you can wait overrule inc...

Страница 10: ......

Страница 11: ......

Страница 12: ...8280 Sundhoffen Tel 33 0 3 89 21 74 70 Fax 33 0 3 89 21 74 74 e ma il in fo rote x fr www ro tex fr DAIKIN AIRCONDITIONING BELGIUM NV A v e n u e F r a n k l i n 1 B B 1 3 0 0 W a v r e Tel 32 0 10 23...

Отзывы: