3 Operation
Operation manual
5
08DA
ROTEX HPSU Bi-Bloc Ultra
4P495263-1C – 2018.11
Item
Description
User settings
Gives access to user settings such as
holiday mode and quiet mode.
Information
Displays data and information about the
indoor unit.
Installer settings
Restriction:
Only for the installer.
Gives access to advanced settings.
Commissioning
Restriction:
Only for the installer.
Perform tests and maintenance.
User profile
Change the active user profile.
Operation
Turn heating/cooling functionality and
domestic hot water preparation on or off.
3.2.3
Setpoint screen
The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Example:
▪ Room temperature screen
▪ Main zone screen
▪ Additional zone screen
▪ Tank temperature screen
a1
d
+
–
d
e
d
e
c
a2
b1
b2
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
Item
Description
Minimum temperature limit
a1
Fixed by the unit
a2
Restricted by the installer
Maximum temperature limit
b1
Fixed by the unit
b2
Restricted by the installer
Current temperature
c
Measured by the unit
Desired temperature
d
Turn the right dial to
increase/decrease.
Submenu
e
Turn or press the left dial to
go to the submenu.
3.2.4
Detailed screen with values
a
b
a
Settings
b
Values
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Possible actions on this screen
Confirm changes and proceed.
3.3
Space heating/cooling control
3.3.1
Setting the space operation mode
About space operation modes
Depending on your heat pump model, you have to tell the system
which space operation mode to use: heating or cooling.
If a … heat pump
model is installed
Then…
Heating/cooling
The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
Heating only
The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.
To tell the system which space operation to use, you can:
You can…
Location
Check
which space operation mode is
currently used
.
Home screen
Set
the space operation
mode
permanently. Main menu
Restrict
automatic changeover
according
to a monthly schedule.
To set the space operation mode
1
Go to [4.1]: Space heating/cooling > Operation mode
2
Select one of the following options:
▪ Heating: Always heating mode
▪ Cooling: Always cooling mode
▪ Automatic:
The
operation
mode
changes
automatically based on the outdoor temperature.
Restricted according to the operation mode
schedule.
To restrict automatic changeover according to a schedule
Conditions:
You set the space operation mode to Automatic.
1
Go to [4.2]: Space heating/cooling > Operation mode
schedule.
2
Select a month.
3
For each month, select an option:
▪ Reversible: Not restricted
▪ Heating only: Restricted
▪ Cooling only: Restricted
4
Confirm the changes.
3.3.2
To change the desired room temperature
During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1
Go to [1]: Room.
You can read out the desired and actual room
temperature in the center of the setpoint screen.
2
Adjust the desired room temperature.
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.