background image

4 Operation

User reference guide

4

08S18+23DA

Daikin Altherma – Low temperature split

4P495251-1 – 2017.12

3.1

Components in a typical system
layout

d

a

b c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface used as room thermostat

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

4

Operation

4.1

User interface: Overview

The user interface has the following components:

a

b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"7.1 To display the help text

in case of a malfunction" on
page 16

 for more information.

LCD screen

The LCD screen has a sleeping function. After a certain time of non-
interaction with the user interface, the screen darkens. Pressing any
button  or  rotating  any  dial  awakens  the  display.  The  time  of  non-
interaction differs depending on the user permission level:

▪ User or Advanced user: 15 min

▪ Installer: 1 h

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

: Turn, then press the left dial. Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

4.2

Possible screens: Overview

The most common screens are as follows:

+

a

b

c

c2

c1

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

Содержание Altherma EHVZ04S18DA6VG

Страница 1: ...r reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W...

Страница 2: ...the contact helpdesk number 16 7 Troubleshooting 16 7 1 To display the help text in case of a malfunction 16 7 2 To check the malfunction history 16 7 3 Symptom You are feeling too cold hot in your li...

Страница 3: ...out this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inf...

Страница 4: ...the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Di...

Страница 5: ...cription Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water temp...

Страница 6: ...About the home screen On the home screen you can read out the most important settings that are meant for daily usage The setup of the unit is displayed in a schematic way See 4 2 1 Home screen on page...

Страница 7: ...cheduling 1 Go to 1 1 Room Schedule 2 Select No 4 4 5 To change the desired leaving water temperature INFORMATION The leaving water is the water that is sent to the heat emitters The desired leaving w...

Страница 8: ...he domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DH...

Страница 9: ...o check if quiet mode is active If is displayed on the home screen quiet mode is active To use quiet mode 1 Go to 7 4 1 User settings Quiet Activation 2 Do one of the following If you want to Then Com...

Страница 10: ...7 2 Setting the energy prices In the system you can set the following energy prices a fixed gas price 3 electricity price levels a weekly schedule timer for electricity prices Refer to the installatio...

Страница 11: ...e main zone in heating mode 3 2 Additional zone Heating schedule Program the desired leaving water temperature for the additional zone in heating mode 4 2 Space heating cooling Operation mode schedule...

Страница 12: ...t C is displayed next to the copied day 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Copy Paste C Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this acti...

Страница 13: ...arameters for the weather dependent curve 2 5 for the main zone and 3 5 for the additional zone see below 4 8 1 Detailed screen with weather dependent curve When weather dependent operation is active...

Страница 14: ...price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minut...

Страница 15: ...lower desired leaving water temperature results in lower energy consumption and better performance Set the desired leaving water temperature in accordance with the heat emitter type Example Underfloo...

Страница 16: ...r living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase...