4 Operation
User reference guide
13
08S18+23DA
Daikin Altherma – Low temperature split
4P495251-1 – 2017.12
2
Select the Rename option.
Delete
Rename
3
Browse through the character list and confirm the
selected character.
4
Confirm the new name.
Usage example: You work in a 3-shift system
If you work in a 3-shift system, you can do the following:
1
Program 3 room temperature schedules in heating mode and
give them appropriate names.
Example:
EarlyShift, DayShift
and LateShift
2
Select the schedule that you currently want to use.
4.8
Weather dependent operation
In space heating control, the leaving water temperature setpoint
mode can be:
▪ Fixed
▪ Weather dependent (the leaving water temperature is determined
automatically depending on the outdoor temperature)
You can change the setpoint mode for the:
▪ Main zone [2.4]
▪ Additional zone (if available) [3.4]
To modify the parameters for the weather-dependent curve ([2.5] for
the main zone and [3.5] for the additional zone, see below.
4.8.1
Detailed screen with weather-dependent
curve
When weather dependent operation is active the desired tank
temperature is determined automatically depending on the averaged
outdoor temperature. When the outdoor temperature is lower the
tank temperature will need to be higher as the water pipes will be
colder and vice versa.
The weather-dependent curves are defined by two setpoints:
▪ Setpoint (X1, Y2)
▪ Setpoint (X2, Y1)
Weather-dependent curve:
X1
Y1
Y2
X2
Y
a
X
Possible actions on this screen
Go through the temperatures.
Change the temperature.
Go to the next temperature.
Confirm changes and proceed.
Item
Description
a
Possible weather dependent zones:
▪
: Main zone or additional zone heating
▪
: Domestic hot water
Item
Description
X, X1, X2
Outdoor ambient temperature
Y, Y1, Y2
Desired tank temperature or leaving water temperature.
The symbol shown here corresponds to the heat emitter
for that zone:
▪
: Underfloor heating
▪
: Fan coil unit
▪
: Radiator
▪
: Domestic hot water tank