background image

DORAI W - Dehumidifier

17

User manual

PART 2.  OPERATING THE UNIT

NOTE: 

When the water in the bucket reaches to a certain level,please be careful to move the machine to avoid it 

falling down.

4. REMOVING THE COLLECTED WATER

1. The first way - use the bucket

•  When the bucket is full, the Full indicator light will 

illuminate, the digital display shows P2.

•  Slowly pull out the bucket. Grip the left and right 

handles securely, and carefully pull out straight so 
water does not spill. Do not put the bucket on the 
floor because the bottom of the bucket is uneven. 
Otherwise the bucket will fall and cause the water to 
spill.

•  Throw away the water and replace the bucket. The 

bucket must be in place and securely seated for the 
dehumidifier to operate.

•  The machine will restore to its original state when the 

bucket is replaced in its correct position.

 

 NOTE

•  When you remove the bucket, do not touch any 

parts inside of the unit. Doing so may damage the  
product.

•  Be sure to push the bucket gently all the way into 

the unit. Banging the bucket against anything or 
failing to push it in securely may cause the unit not 
to operate.

•  When you remove the bucket,if there is some 

water in the unit you must dry it .

Fig. 5

1.  Pull out the bucket a little

2.  Hold both sides of the bucket with even 

strength, and pull it out from the unit. 

3.  Pour the water out.

Fig. 6

2. The second way - continuous draining

•  Water can be automatically emptied into a floor drain by attaching the unit with a water hose (not included).
•  Remove the rubber plug from the back drain hose outlet. Attach a drain hose(ID=13.5mm) and lead it to the 

floor drain or a suitable drainage facility (see Fig.7).

•  Make sure the hose is secure so there are no leaks. 
•  Direct the hose toward the drain,making sure that there are no kinks that will stop the warter flowing.
•  Place the end of the hose into the drain and make sure the end of the hose is level or down to let the water flow 

smoothly. Do never let it up.

Содержание Dorai D16W

Страница 1: ...ENG DORAI W Dorai D16W Dorai D20W User manual...

Страница 2: ...ontrol panel and functions 12 Other features 13 PART 2 OPERATING THE UNIT 15 Identification of parts 15 Positioning the unit 15 When using the unit 16 Removing the collected water 17 PART 3 CARE AND M...

Страница 3: ...s D Products of this type contains valuable elements it can be sold sprzedane on purchase of metals Throwing the device on wild exposes you to the risk of losing your health Dangerous substances from...

Страница 4: ...d be paid attention by the user Otherwise operation error can cause damage to the product or other losses Notice Sign Never do this Always do this Do not exceed the rating of the power outlet or conne...

Страница 5: ...places where water may splash onto the unit Water may enter the unit and degrade the insulation It may cause an electric shock or fire Never insert your finger or other foreign objects into grills or...

Страница 6: ...Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not open th...

Страница 7: ...flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that the refrigerants may not contain an odour Appliance should be installed operated and stored in a...

Страница 8: ...cing 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimised For repair to the refrigerat...

Страница 9: ...tinuestobevisibleandlegible Markingsandsignsthatareillegibleshallbecorrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which m...

Страница 10: ...ntsbuttheuseofdetergentscontainingchlorineshallbeavoidedasthechlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be removed extinguis...

Страница 11: ...ecovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order The recovery equipment shall be in good working order with a set of i...

Страница 12: ...normal 10 Mode pad Press to select the desired operation mode from Dehumidifying Dryer Continuous dehumidifying and Smart dehumidifying NOTE Dryer and Smart dehumidifying modes are optional 11 Up Down...

Страница 13: ...elative Humidity Error Codes and Protection Codes AS Humidity sensor module error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and...

Страница 14: ...at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Or Auto Stop feature When LED display window displays the code of P2 the Auto Start or Auto Stop feature will also be cance...

Страница 15: ...little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Do not use outdoors This dehumidifier is intended f...

Страница 16: ...er in the bucket The unit may tip over and spill water NOTE Casters is optional 3 WHEN USING THE UNIT When first using the dehumidifier operate the unit continuously 24 hours This unit is designed to...

Страница 17: ...do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way into the unit Banging the bucket against anything or failing to push it in secur...

Страница 18: ...ose from the outlet and attach the rubber plug back to the drain outlet Make sure the water hose is lower than the drain hose outlet Select the desired humidity setting and fan speed on the unit for c...

Страница 19: ...ldew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter The air filter behind the front grille...

Страница 20: ...kles of the filter first and then pat the bottom bukcle CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance NOTE The cabinet and front ma...

Страница 21: ...r back of the dehumidifier The humidity selector may not be set low enough Checkthatalldoors windowsandotheropeningsaresecurelyclosed Room temperature is too low below 5 C 41 F There is a kerosene hea...

Страница 22: ...DORAI W Dehumidifier 22 User manual NOTES...

Страница 23: ...DORAI W Dehumidifier 23 User manual NOTES...

Страница 24: ...www rotenso pl email info rotenso pl Installer stamp...

Отзывы: