Page 65 of 82 Revision No.: 1.5
13) Appendix B: RF
In order to configure RF communication you need to set the baud rate and channel on
both sides of the RF.
1.
Configuration (DIP 1)
: In order to configure new parameters: move DIP switch
to 'on' state, arrange all parameters according to the following section, press reset,
wait until LED RX is off. Move Config to OFF.
2.
Baud rate (DIP 2, 3)
: Baud rate is the communication bit rate beetween
PC/controller and the RFC/RFR – the UART default baud rate is 9600bps. All
states are summarized in
Table 4
.
Table 2: Baud rate states
If RFR is being used and the connection is to several controllers in different
distances, you should reduce baud rate until you establish connection with no
errors. The 19200 bps is not recommended for use.
3.
Address (DIP 4, 5)
: for future use. Note that it must be at OFF position.
4.
Channel (DIP 6, 7, 8
)
:
Set the module’s hopping channel number (see
Fig. 76
). A
channel is one of three layers of addressing available to the XStream radio
modem. In order to module to communicate with each other, the modules must
have the same channel number since each network uses a different hopping
sequence. Different channels can be used to prevent modules in one network from
listening to transmissions of another.
Table 4
summarizes all possible Jumper
modes.
Note that it is very important to verify no communication disturbance occurs in
neighboring farms.
Table 3: Jumper modes summary
DIP 2
DIP 3
Baud's state
Baud's rate
OFF OFF 0 9600
bps
OFF ON 1 2400
bps
ON OFF 2 4800
bps
ON ON 3
19200
bps
Jumper 6
Jumper 7
Jumper 8
Channel
0 0 0 CHAN-0
1 0 0 CHAN-1
0 1 0 CHAN-2
1 1 0 CHAN-3
0 0 1 CHAN-4
1 0 1 CHAN-5
0 1 1 CHAN-6
1 1 1 CHAN-0
Содержание communicator
Страница 1: ...Communicator User s Manual...
Страница 13: ...Page 12 of 82 Revision No 1 5 Fig 3 Communicator s menu structure...
Страница 45: ...Page 44 of 82 Revision No 1 5 9 Flow chart of Voice Dial out Process...
Страница 46: ...Page 45 of 82 Revision No 1 5...
Страница 49: ...Page 48 of 82 Revision No 1 5 Fig 85 Functional block diagram...
Страница 50: ...Page 49 of 82 Revision No 1 5 Fig 86 Wiring Diagram using RF communication card...
Страница 51: ...Page 50 of 82 Revision No 1 5 Connect the Local PC either by using COM Port cable or by using the USB cable...
Страница 58: ...Page 57 of 82 Revision No 1 5 11 2 RF Network Connection Option A with Platinum Plus RF RCLP RF...