page 52
May 01/2007
Effectivity: 912 Series
Edition 1 / Rev. 0
d04054
INSTALLATION MANUAL
BRP-Rotax
12.5) Determination of operating limits, Coolant and necessary modifica-
tion on radiator installation
Depending on the achieved maximum values of the cylinder head temperature
and the coolant temperature following action are necessary.
1)
engine type 912 ULS/S
2)
engine type 912 UL/A/F
a)
Maximum cylinder head temperature is below operating limit. Operating with
waterless coolant, is permissible without modification to the installation.
b)
Maximum cylinder head temperature and coolant exit temperature is below
operating limit.
For operating with conventional coolant it is necessary to monitoring
constantly cylinder head temperature and coolant exit temperature.
◆
NOTE:
For detection of possible indication error an additional monitor-
ing of the cylinder head temperature is necessary which shows
an exceedingin case of coolant loss.
The aircraft manufacturer has the option of converting the coolant temperature
and the cylinder head temperature to an aircraft specific cylinder head tem-
perature. This is possible by calculating the difference between the head
material and the coolant temperature.
This is done by following the flight test procedure on page 53.
Coolant
temperature
Cylinder head
temperature
Additional instruments for
displaying coolant
temperature is necessary
b)
more than
135 °C
1)
(275 °F)
150 °C
2)
(300 °F)
Modifications to the instruments
or limit not necessary
a)
Cooling capacity too low. Check
of the installation necessary
c)
Cooling capacity too low.
Check of the installation
necessary
c)
more than
135 °C
1)
(275 °F)
150 °C
2)
(300 °F)
less than
135 °C
1)
(275 °F)
150 °C
2)
(300 °F)
less than
135 °C
1)
(275 °F)
150 °C
2)
(300 °F)
less than
120 °C (248 °F)
more than
120 °C (248 °F)
less than
120 °C (248 °F)
more than
120 °C (248 °F)
maximum values for
Conventional coolant
Waterless coolant
coolant used for tests
08358
Содержание 912 ULS 3
Страница 1: ...45 5 0 6 03 305 9 5 1 4 3 4 QBSU OP 898642 305 9 6 4 8 5 015 0 4 2 2 4 3 Ref No IM 912...
Страница 6: ...page 6 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04050 INSTALLATIONMANUAL BRP Rotax NOTES...
Страница 10: ...page 10 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04051 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 16: ...page 16 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04051 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 18: ...page 18 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04051 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 20: ...page 20 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04051 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 26: ...page 26 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04052 INSTALLATIONMANUAL BRP Rotax NOTES...
Страница 30: ...page 30 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04052 INSTALLATIONMANUAL BRP Rotax NOTES...
Страница 46: ...page 46 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04053 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 90: ...page 90 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04056 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 98: ...page 98 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04057 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 120: ...page 120 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04059 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 124: ...page 124 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04060 INSTALLATION MANUAL BRP Rotax Fig 82 08328...
Страница 134: ...page 134 May 01 2007 Effectivity 912 Series Edition 1 Rev 0 d04060 INSTALLATION MANUAL BRP Rotax NOTES...
Страница 135: ......