2.1) Operating limits
General
ATTENTION
Monitor Operating limits. Limits must not be exceeded. If one or
more operating limits are exceeded, the engine must be operated so
that the values fall back into the allowed range. Carry out instruc-
tions for abnormal operation
performance is measured under following boundary conditions:
• Standard engine (without governor). Without auxiliary equip-
ment (e.g. external alternator)
• Installation in accordance with installation guidelines (e.g. in-
take and exhaust system). See latest Installation Manual
• ISA Condition(
I
nternational
S
tandard
A
tmosphere)
Engine speed
Parameter
Min.
Max.
Engine speed at idle
1800 rpm
–
Engine speed
–
5800 rpm (max. 5
minutes)
Performance
The engine performance is approximately proportional to the
airflow value and can be calculated as follows:
Observed Power [kW] ~-6.3264+0.0169*Airflow [g/min]
Parameter
Min.
Max.
Take-off Performance
(engine speed: 5800
rpm)
–
104 kW
Continuous Perform-
ance (engine speed:
5500 rpm)
–
99 kW (without
governor)
Critical Altitude (MAT:
max. 50 °C (120 °F))
15000 ft
NOTE
The max. Continuous performance is available up to the critical
altitude.
Page 2-2
December 01 2017
BRP-Rotax
Effectivity: 915 i A Series
Edition 0 / Rev. 0
Содержание 898851
Страница 4: ...Page Notes 2 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0 NOTES...
Страница 6: ...Page Notes 2 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0 NOTES...
Страница 60: ...Page Notes 8 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0 NOTES...
Страница 64: ...Page Notes 4 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0 NOTES...
Страница 84: ...Page Notes 4 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0 NOTES...
Страница 86: ...9 1 Form Figure 1 Form Page 9 2 December 01 2017 BRP Rotax Effectivity 915 i A Series Edition 0 Rev 0...
Страница 136: ......
Страница 139: ......