background image

9

Purpose

This procedure establishes the minimum requirements for the lockout of energy that could cause injury to 

personnel by the operation of lifts in need of repair or being serviced. All employees shall comply with this 

procedure.

Responsibility

The responsibility for assuring that this procedure is followed is binding upon all employees and service 

personnel from outside service companies (i.e., Authorized Rotary Installers, contactors, etc.). All employees 

shall be instructed in the safety significance of the lockout procedure by the facility owner/manager. Each 

new or transferred employee along with visiting outside service personnel shall be instructed by the owner/

manager (or assigned designee) in the purpose and use of the lockout procedure.

Preparation

Employees authorized to perform lockout shall ensure that the appropriate energy isolating device (i.e., 

circuit breaker, fuse, disconnect, etc.) is identified for the lift being locked out. Other such devices for other 

equipment may be located in close proximity of the appropriate energy isolating device. If the identity of the 

device is in question, see the shop supervisor for resolution. Assure that proper authorization is received 

prior to performing the lockout procedure.

Sequence of Lockout Procedure

1)  Notify all affected employees that a lockout is being performed and the reason for it.

2)  Unload the subject lift. Shut it down and assure the disconnect switch is “OFF” if one is provided on 

the lift.

3)  The authorized lockout person operates the main energy isolation device removing power to the 

subject lift.

•  If this is a lockable device, the authorized lockout person places the assigned padlock on 

the device to prevent its unintentional reactivation. An appropriate tag is applied stating the 

person’s name, at least 3” x 6” in size, an easily noticeably color, and states not to operate 

device or remove tag.

•  If this device is a non-lockable circuit breaker or fuse, replace with a “dummy” device and 

tag it appropriately as mentioned above.

4)  Attempt to operate lift to assure the lockout is working. Be sure to return any switches to the “OFF” 

position.

5)  The equipment is now locked out and ready for the required maintenance or service.

Restoring Equipment to Service

1)  Assure the work on the lift is complete and the area is clear of tools, vehicles, and personnel.

2)  At this point, the authorized person can remove the lock (or dummy circuit breaker or fuse) & tag 

and activate the energy isolating device so that the lift may again be placed into operation.

Rules for Using Lockout Procedure

Use the Lockout Procedure whenever the lift is being repaired or serviced, waiting for repair when current 

operation could cause possible injury to personnel, or for any other situation when unintentional operation 

could injure personnel. No attempt shall be made to operate the lift when the energy isolating device is 

locked out.

LIFT LOCKOUT/TAGOUT PROCEDURE

Содержание SPO12 Hummer 5W0 Series

Страница 1: ...wing Arm Frame Engaging Lift Standard 500 700 Series Capacity 12 000 lbs Hummer 5W0 7W0 Series Capacity 12 000 lbs Sprinter 5A0 7W0 Series Capacity 9 000 lbs June 2018 by Vehicle Service Group All rig...

Страница 2: ...hicle if locking latches are not engaged Do Not block open or override self closing lift controls they are designed to return to the Off or Neutral position when released Do Not remove or disable arm...

Страница 3: ...res to periodically maintain the lift in accordance with the lift manufacturer s instructions or ANSI ALI ALOIM 2000 American National Standard for Automotive Lifts Safety Requirements for Operation I...

Страница 4: ...htly move arm to allow restraint gear and pawl to mesh DO NOT hammer pin down as this will damage the restraint gear teeth C Raise vehicle until tires clear the floor D Stop and check adapters for sec...

Страница 5: ...l Spotting Positions D Pull LOWERING valve handle to lower Fig 3 Note Both LATCH release and LOWERING valve handles are deadman type design Each must be held down to lower lift Do not override self cl...

Страница 6: ...ographs shown are generic in nature and are meant to generally represent hazards common to all automotive lifts regardless of specific style Funding for the development and validation of these labels...

Страница 7: ...o drill holes 2 Break out old concrete and repour new pads for lift per lift installation instruction 1 Remove covers oil latch mechanism Depress latch release handle several times to allow oil to coa...

Страница 8: ...8 TROUBLE SHOOTING Trouble Lift will not raise off of latches Remedy 1 Contact lift manufacturer s Customer Service Cause 1 Motor pump or cylinder failure...

Страница 9: ...t 2 Unload the subject lift Shut it down and assure the disconnect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power...

Страница 10: ...umber Air Electric Utility Box FA5911 Air Electric Utility Box Without FRL FA5910 Filter Regulator Lubricator FRL FA5166 OPERATING CONDITIONS Lift is not intended for outdoor use and has an operating...

Страница 11: ...11 NOTES...

Страница 12: ...ce Assistance Contact your local Rotary distributor Should further assistance be required contact Rotary Lift at one of the phone numbers listed below Certificate of Compliance Rotary Lift is authoriz...

Страница 13: ...rficiedeDosPostesMontadoconMarcodeBrazodeOscilaci n Standard Series 500 700 Capacidad 12 000 libras Hummer Series 5W0 7W0 Capacidad 12 000 libras Sprinter Series 5A0 7W0 Capacidad 9 000 libras Junio d...

Страница 14: ...r debajo del veh culo si los seguros de cierre no est n asegurados No bloquee o anule los controles de auto cierre del elevador est n dise ados para regresar a la posici n de Apagado o Neutral cuando...

Страница 15: ...ara darle mantenimiento peri dicamente el eleva dor de acuerdo con las instrucciones del fabricante del elevador o con ANSI ALI ALOIM 2000 Normas Nacionales Americanas para los Requerimientos de Segur...

Страница 16: ...an NO martille el perno ya que esto da ar los dientes del engrane de restricci n C Levante el veh culo hasta que los neum ticos se despeguen del piso D Det ngase y verifique los adaptadores para asegu...

Страница 17: ...el liberador de SEGUROS como de la v lvula de DESCENSO son dise adas tipo punto muerto Cada una debe ser sujetada hacia abajo para descender el elevador No anule los controles de auto apagado del elev...

Страница 18: ...pesados ALI WL101c S lo personal autorizado En el rea del elevador PRECAUCI N Utilice los puntos de elevaci n del fabricante del veh culo Utilice los extensores de altura cuando se necesiten para aseg...

Страница 19: ...retorno del aceite 1 Ajuste los cables del ecualizador a su tensi n correcta 2 Calce el elevador al nivel de las columnas Que no exceda 1 2 Si es m s de 1 2 perfore el piso y nivele de acuerdo con la...

Страница 20: ...as instrucciones de instalaci n del elevador 1 Reemplace el cable 2 Instale el conducto de nuevo en el soporte ajuste la tensi n del cable 3 Ajuste la tensi n del cable 1 Contacte a Servicio al client...

Страница 21: ...nterruptor de desconexi n en el elevador est en APAGADO 3 La persona autorizada para el realizar el bloqueo ser la encargada de cortar la corriente utilizando el dispositivo de aislamiento de energ a...

Страница 22: ...tensilios El ctricos De Aire FA5911 Caja de Utensilios El ctricos De Aire Sin FRL FA5910 Filtro Regulador Lubricante FRL FA5166 CONDICIONES DE OPERACI N El elevador no esta dise ado para uso exterior...

Страница 23: ...23 NOTAS...

Страница 24: ...el est ndar ANSI UL 201 y el est ndar CSA C22 2 No 68 del Underwriters Laboratories Inc SV0021 B Rev 5 2 14 Oficinas centrales en el mundo de Rotary 2700 Lanier Drive Madison IN 47250 USA www rotaryli...

Страница 25: ...t de cadre avec bras oscillant mont s par deux montants de surface Standard S ries 500 700 Capacit 12 000 livres Hummer S ries 5W0 7W0 Capacit 12 000 livres Sprinter S ries 5A0 7W0 Capacit 9 000 livre...

Страница 26: ...z pas les commandes d ouverture ou d annulation de fermeture automatique qui sont con ues pour revenir en position Off ou Neutre lorsqu elles sont l ch es Ne pas retirer ou d sactiver les retenues de...

Страница 27: ...on inspection Doivent mettre en place des proc dures d entretien p riodique selon les instruc tions du fabricant de l l vateur ou ANSI ALI ALOIM 2000 de American National Standard for Automotive Lifts...

Страница 28: ...rement le bras pour permettre aux accessoires d arr t et aux cliquets de verrouillage de s engager NE PAS marteler la goupille pour l enfoncer car ceci endommagerait les dents des engrenages d arr t C...

Страница 29: ...a roue D Poussez la poign e de la valve de DESCENTE vers le bas Figure 3 Remarque Les poign es de lib ration du LOQUET et les valves D ABAISSEMENT sont de type de s curit bloqueur Les deux doivent tre...

Страница 30: ...r ATTENTION Utilisez les points de levage du manufacturier Utiliser des extensions de hauteur si n cessaire pour assurer un bon contact Des adaptateurs secondaires peuvent r duire la capacit de charge...

Страница 31: ...on 3 R installez le tube de retour d huile 1 R glez les c bles galiseurs pour corriger la tension 2 Posez des cales pour mettre les colonnes au niveau ne pas d pas ser 1 2 Si plus de 1 2 cassez le pla...

Страница 32: ...emplacez le c ble 2 Reposez le conduit dans le support ajustez la tension du c ble 3 Ajustez la tension du c ble 1 Veuillez contacter le service la client le du fabricant de l l vateur Raison 1 Arbres...

Страница 33: ...r l l vateur 3 La personne autoris e au verrouillage fait fonctionner le dispositif d isolement d nergie principal ce qui met l l vateur en question hors tension Si c est un dispositif verrouillable l...

Страница 34: ...ion air lectrique FA5911 Bo te d utilisation air lectrique sans FRL FA5910 Filtre r gulateur lubrificateur FRL FA5166 CONDITIONS DE FONCTIONNEMENT L l vateur n est pas pr vu pour une utilisation l ext...

Страница 35: ...35 REMARQUES...

Страница 36: ...ur courant alternatif conforme la norme Underwriters Laboratories Inc standard ANSI UL 201 CSA standard C22 2 No 68 SV0021 B R vision 5 2 14 Rotary Si ge social mondial 2700 Lanier Drive Madison IN 47...