Error Message on LCD
Liquid Detected In Containment
(No Liquid Found In Containment)
1. Possible Causes
(Pressure Sensor Fault)
Error message on LCD
No error message on LCD
1. Call a Rotary Authorized Installer
for assistance.
2. Fault: Plugged or kinked sensor
tube.
Fix: Check by removing air connec
tion to pressure sensor. If LDS
(Liquid Detection System) error
deactivates, blow out tube or repair
kink.
If LDS (Liquid Detection System)
stays activated, replace pressure
sensor.
3. See air system diagram Fig 7.
LOWERING VALVE CIRCUIT
FAULT
1. Touch pad defect
2. Defective latch air valve in master
control panel.
1. Check lowering valve plug on
power unit. If connection is good and
you are still getting this error contact
an authorized Rotary repairperson
1. Contact authorized Rotary
repairperson
2. Contact authorized Rotary
repairperson
TROUBLE SHOOTING
in
bay
Master Control Panel
Raise Lift/Scroll Up
Lower Lift/Scroll Down
Mode Button
Main Selection/Lower to Locks
Trouble
Cause
Remedy
UP button pressed but lift doesn't raise
UP button pressed but lift doesn't raise
UP button pressed but lift doesn't raise
UP button pressed but lift doesn't raise
UP button pressed but lift doesn't raise
Trouble
Cause
Remedy
DOWN button pressed but lift doesn't lower
DOWN button pressed but lift doesn't lower
DOWN button pressed but lift doesn't lower
DOWN button pressed but lift doesn't lower
DOWN button pressed but lift doesn't lower