background image

IN0P

AF650000000XX

OBM_IB_P

A-F65_EN_SW_v

er1433

 www.rossmax.com

Replacing the battery:

1.  Loosen  the  screw  of  the  bat

-

tery  cover  on  the  back  of  the 
unit,  and  remove  the  battery 
cover  by  pulling  it  off  in  the 
direction of the arrow.

     Use  a  small  screwdriver  to 

loosen  the  screw  on  the  bat

-

tery cover.

2.  Remove  the  battery  with  a 

thin, sturdy, stick that will not 
break easily.

Total Steps Taken

Today’s Total

Fitting Mode Results

Diet Control

One day before (yesterday) 
memory of daily steps count 
and calories burned

One day before (yesterday) 
memory of lost weight 
and consumed calories

Two days before memory 
of daily steps count and 
calories burned

Two days before memory of 
lost weight and consumed 
calories

Seven days before memory 
of daily steps count and 
calories burned

Seven days before 
memory of lost weight 
and consumed calories

1.  Please make sure the activity monitor is not under fitting 

mode.

2.  Press and hold the memory key for approximately 5 sec

-

onds.

3.  When the word “ cLr” has been displayed on the screen, 

the measurement values in the memory zone are erased.

Note:

The measurement values stored in memory are deleted, but 
the  date,  gender,  height  ,weight,  stride  length  and  target 
settings are not deleted.

Phenomenon Cause

Rectification

 Blinks 

or appears 

continuously

Battery power weak 

or exhausted

Replace a new 3V 

Lithium battery type 

CR2032

Nothing is 

displayed

Polarities of battery 

(+ and -) aligned in 

wrong directions

Insert battery in cor

-

rect alignment

Battery power weak  

or exhausted

Replace a new 3V 

Lithium battery type 

CR2032

Power-saving 

 

function is active

Press either display 

key,   or memory key

Displayed 

values are 

incorrect

The unit is attached 

incorrectly

Follow instructions

1. Maintenance

     Always keep the unit clean. The unit should be cleaned 

with  a  soft  dry  cloth.  To  remove  stubborn  stains,  wipe 
the unit with damp cloth moistened with water or mild 
detergent. Then wipe it dry.

2.  Maintenance and storage precautions.

     Do not use volatile liquids, such as benzene, or thinner, 

to clean the unit.

3.  Please observe the following storage condition.

    •  Do not disassemble the unit.
    •  Do not subject the unit to strong shocks or vibrations, 

drop it, step on it, or leave it at an angle.

    •  Do not immerse the unit or any of the components in 

water.  The  unit  is  not  waterproof.  Do  not  wash  it  or 
touch it with wet hands. Be careful that water does not 
get into the unit.

    •  Do not subject the unit to extreme temperatures, humid

-

ity, moisture, or direct sunlight.

    •  Do not store the unit where it will be exposed to chemi

-

cal or corrosive vapours.

1.  If the 

 symbol blinks or appears on the display, replace 

the battery with a new (CR2032) battery.

2.  If the battery is removed, the time will be reset to “0:00”, 

please refer to “Setting“ procedure at point 5 and point 
6  to  reset  the  hour  and  minute  after  inserting  the  new 
battery.

Note: 

•  When battery is removed, only the time will be reset, the 

measurement values stored in memory and the data set

-

tings  like  the  date,  gender,  height  ,weight,  stride  length 
and target are not deleted.

Clearing Values from Memory 

To Recall the Memory

Troubleshooting

Maintenance and storage

Specification

Replacing the Battery

Measurement 

Range of Daily Total

Steps: 0-99999 steps

Calorie: 0-9999 kcal

Measurement 

Range of Fitting 

mode

Time : 0’00”-999’59”

Calorie: 0-9999 kcal

Diet Calorie :0-9999 kcal

Already Lost Weight: 0.000-9.999 kg

Setting

Time : 0:00 to 23:59 (24 -hr)

Gender: Male/Female

Height: 100-199cm

Weight: 30.0-150.0 kg

Stride: 30-120cm

Weight lose target: 0.1kg - (weight*0.04)kg 

(default: 1.0 kg)

Accuracy of Steps

±5% (vibration testing machine)

Operation 

environment 

Temperature: -10°C to 40°C ; 

 

Humidity: 30 to 85% RH

Storage and 

Transportation 

environment

Temperature: -20°C to 60°C ; 

 

Humidity: 30 to 95% RH

Dimension

77.4 (L) * 36.0 (W) * 11.4 (H) mm

Weight

28.0 g (G.W.) (w/ Battery)

Battery type

3V Lithium battery type CR2032*1

Battery life

Approximately 6 months (when used for 2 

hours a day, approximately 10,000 steps)

1.  Contact your doctor or healthcare provider before begin

-

ning a weight reduction or exercise program.

2.  Keep the unit out of the reach of young children.
3.  Please  consult  a  doctor  immediately,  if  young  children 

swallow the battery, battery cover or screw.

4.  Do not put the unit in the back pocket of your shorts or 

trousers. It could be damaged if you sit down while the 
unit is still in your pocket.

5.  Do not swing the unit by strap that may cause an injury.
6.  If battery fluid should get in your eye, immediately rinse 

with plenty of clean water. Consult a doctor immediately.

7.  If battery fluid should get in your skin or clothing, imme

-

diately rinse with plenty of clean water.

8.  Do not insert the battery with the polarities in the wrong 

direction.

9.  Always use the type of battery indicated.
10.  Replace a worn battery with a new one immediately
11.  Remove the battery from this unit when you are not go

-

ing to use it for long period of time.

12.  Do not throw the battery into fire, it may explode
13.  When  disposing  the  product,  remove  the  battery  and 

follow local regulations on environmental protection.

Cautions

Press memory key

Press Fitting mode key

Press display key

Date and Time

Steps count and 
calories burned 
during a day

Fitting calories consumed 
and recommended daily 
calories burned

Already lost weight 
and recommended diet 
calories during a day

Reviewing the Data

Cases where the 

unit may not be 

able to count steps 

accurately

Refer to section of 

“How to attach the 

unit” 

Settings are wrong

Change settings

The display is unusual or the 

 

buttons do not operate normally

Remove the battery 

then insert it again

Note:

 

•  Do  not  use  a  pair  of  metal 

tweezers or a screwdriver.

3.  Insert  the  battery  (CR2032) 

with  the  positive  (+)  side 
face up.

4.  Replace  the  battery  cover 

by sliding the catch in first, 
then tighten the screw.

 

 WARNING:

 

The symbol on this product means that it’s an 

electronic product and following the European directive 

2012/19/EU the electronic products have to be dispose on 

your local recycling centre for safe treatment.

Manufacturer: 

Rossmax Swiss GmbH,  

Tramstrasse 16, CH-9442 Berneck, Switzerland

Отзывы: