background image

EU Conformity Declaration

We herby declare that the following electric appliances in their design and construction and in all versions distributed by us 

comply with the essential requirements of the  following standards. 

Alterations and modifications of the  appliances not approved by us invalidate this declaration.

Description of the electric appliances: Fire Brigade Suction Pump

Appliance types: Hydra-Boy

Power consumption: 1200 W / 900 W

EU Directive:  2006/42/EG

harmonised standards

EN 60 335-1 : 2002 + A1 : 2004 + A11 : 2004 + A2 : 2006 + A12 : 2006 +  A13 : 2008 + A14 : 2010/Part1  

EN 60 335-2-69 : 2003 + A1 : 2004 + A2 : 2008/Part 2-69  EN 60335-2-41: 2003 + A1 : 2004/Part 2-41  

EN 62 233 : 2008

Signature: ______________________

Name of signer   Hubert Rössle

Funktion des Unterzeichners: CEO

Signer‘s function:

Rössle AG 

Pater-Hartmann-Str. 23

87616 Marktoberdorf,  Germany

Datum / Date: 10.02.2014

14

EU Conformity Declaration

Hubert Rössle

Name des Bevollmächtigten der 

technischen Unterlagen nach  

MRL 2006/42/EG: 

Rössle AG 

Pater-Hartmann-Str. 23

87616 Marktoberdorf,  Germany

Содержание Hydra-Boy

Страница 1: ...Bedienungsanleitung Feuerwehrsauger Operating instructions Fire Brigade Suction Pump ...

Страница 2: ... 900 W Schmutzwasserpumpe 13 000 l h Pumpleistung 8 m Saugschlauch 10 m Ablaufschlauch 38 mm 10 m 19 kg Achtung Den Feuerwehrsauger nur mit FI Schalter 30mA betreiben Elektrische Anschlußstellen müssen einen Schutzkontakt haben Pumpe darf nicht trocken laufen bitte Bedienungsanleitung beachten 2 ...

Страница 3: ...1 1 2 2 1 2 1 20 2 1 3 2 5 12 11 10 14 13 1 20 2 2 5 13 12 14 13 13 11 15 1 3 ...

Страница 4: ...augschlauch das abzusaugende Medium durch Unterdruck eingesaugt wird Eine im Behälter montierte Pumpe befördert das Schlammwasser kontinuierlich über den Ablaufschlauch ins Gelände oder in die Kanalisation Absaugen ist somit in der Regel ohne Unterbrechung möglich Der Feuerwehrsauger darf nicht als Trockensauger sondern nur als Wassersauger betrieben werden Saugen ohne Schwammfilter 1 4 sowie unsa...

Страница 5: ...ass kein Rückfluss des abgepumpten Wassers stattfinden kann Probleme beim Saugen siehe Abb 9 12 Hinweis Zum Schutz des Feuerwehrsaugers ist eine Abregelautomatik eingebaut die beim Auslösen trotz laufender Turbine die Saugkraft stoppt Ein Nachlassen der Saugleistung kann folgende Ursachen haben der Netzfiltersack 2 4 ist voller Schmutz Bitte öffnen Sie den Reißverschluß am Netzfiltersack 2 4 und e...

Страница 6: ... Wasser oder eine andere Flüssigkeit tauchen Saugkopf 1 niemals unter fließendes Wasser halten und immer vor Spritzwasser schützen Zum Reinigen den Netzstecker 1 3 ziehen und den Saugkopf 1 mit einem feuchten Tuch abwischen Reinigen Sie den Feuerwehrsauger stets nach beendeter Arbeit Niemals den Feuerwehrsauger vor Arbeitsbeginn reinigen Wickeln Sie zum Saugen die Anschlussleitung 1 3 vollständig ...

Страница 7: ...l Schäden die durch Einbau und Bedienungsfehlern Kalkablagerungen mangelnde Pflege Frosteinwirkung normalem Verschleiß oder unsachgemäßen Reperaturversuchen entstanden sind fallen nicht unter diese Garantie Bei Veränderungen an dem Gerät z B abschneiden der Netzanschlussleitungen oder des Netzsteckers erlischt der Garantieanspruch Für Folgeschäden die durch Ausfall des Gerätes oder unsachgemäßen B...

Страница 8: ...gsaufnahme 1200 W 900 W Einschlägige EG Richtlinien 2006 42 EG Harmonisierte Normen EN 60 335 1 2002 A1 2004 A11 2004 A2 2006 A12 2006 A13 2008 A14 2010 Part1 EN 60 335 2 69 2003 A1 2004 A2 2008 Part 2 69 EN 60335 2 41 2003 A1 2004 Part 2 41 EN 62 233 2008 Unterschrift Signature ______________________ Name des Unterzeichners Hubert Rössle Funktion des Unterzeichners CEO Rössle AG Pater Hartmann St...

Страница 9: ... l h Suction power 900 W Sewage pump 13 000 l h Pump Power 10 m Suction hose 10 m Drain hose 38 mm 10 m 19 kg Attention Only suitable with a FI switch 30mA and has to be connected to a regular safety plug socket Never let the pump run dry Follow the operating instructions GB 8 ...

Страница 10: ...1 1 2 2 1 2 1 20 2 1 3 2 5 12 11 10 14 13 1 20 2 2 5 13 12 14 13 13 11 15 1 9 ...

Страница 11: ...d is sucked up by negative pressure through a suction tube and a suction hose A pump which is built in to the container continuously pumps the dirty water through a drainage hose into the open or into the waste water system This means that the suction activity is normally possible without any break The fire brigade suction cleaner should not be used as a dry suction cleaner but only for sucking up...

Страница 12: ...es not flow back into the cellar again Problems during suction operations see figs 9 12 Please note In order to protect the fire brigade suction cleaner there is a built in automatic switch which when activated stops the suction activity in spite of the fact that the turbine is still running A reduction in the suction power can be caused by the following the net filter sack 2 4 is full of dirt Ple...

Страница 13: ...rotected against splashing In order to clean it disconnect the mains power plug 1 3 and wipe down the suction head 1 with a dry cloth Always clean the fire brigade suction cleaner after finishing work Never clean the fire brigade suction cleaner before starting work For suction operations unwind the connecting power cable 1 3 completely Never pull the fire briga de suction cleaner using the connec...

Страница 14: ...ling calcium deposits lack of care frost damage normal wear and tear or unqualified attempts at repairs are not included in this guarantee If any changes are made to the equipment for example cutting off the power cables or the mains power plug the guarantee will be cancelled We are not responsible for damage resulting from the machine breaking down or from improper handling In guarantee cases ple...

Страница 15: ...consumption 1200 W 900 W EU Directive 2006 42 EG harmonised standards EN 60 335 1 2002 A1 2004 A11 2004 A2 2006 A12 2006 A13 2008 A14 2010 Part1 EN 60 335 2 69 2003 A1 2004 A2 2008 Part 2 69 EN 60335 2 41 2003 A1 2004 Part 2 41 EN 62 233 2008 Signature ______________________ Name of signer Hubert Rössle Funktion des Unterzeichners CEO Signer s function Rössle AG Pater Hartmann Str 23 87616 Marktob...

Страница 16: ...R Ö S S L E A G Johann Georg Fendt Straße 50 D 87616 Marktoberdorf Telefon 49 0 8342 2314 Fax 49 0 8342 95482 info roessle ag w w w r o e s s l e a g V e r s i o n 1 2 _ 1 7 ...

Отзывы: