Enrollment
22
MD-W11 Installation Manual
4.
Enrollment
Prevent loss of transmission data by enrolling each pair of Near and
Far Units.
4.1
Enrolling the Units
One unit cannot recognize the unique ID of another unit unless both
units are enrolled so that they can work together.
4.2
DIP Switches
The DIP switches on both units are set as shown in Table 1.
Table 1: DIP Switch Settings
DIP Switches 1–4
Not used
Must be in the ON position
DIP Switch 5
OFF or ON
Used to set the channel
DIP Switch 6
OFF or ON
Used to set the channel
DIP Switch 7
Enrolling
Normal mode – ON
Enrolling mode – OFF
DIP Switch 8
Not used
Must be in the ON position
Only handle the DIP switches when the power is off.
Up is ON
Down is OFF
1 2 3 4 5 6 7 8