Controller Operation 

AYC-Ex5/T65 Series Installation and Programming Manual 

41 

There are four different ways to program the Normal/Bypass 

code and door chime. 
Enter the code 

0000

 to disable both Bypass 

code and the door chime. 

 

Enter the code 

0001

 to disable the Bypass 

code and enable the door chime. 

 

Enter any code ending with 0 to enable the 

Bypass code and disable the door 

chime. 

 

Enter a code not ending with 0 to enable the 

Bypass code and enable the door 

chime. 

 

You hear three beeps. 
The system returns to Normal mode. 

 

4.9.8

 

Setting Fail Safe/Secure Operation, Tamper Siren 

and Lock Strike Release Time 

 

The default value is 0004, which corresponds to Fail Secure 

operation, no siren, and a 4-second Lock Strike release time. 

To set the Fail Safe/Secure Operation, Tamper Siren and Lock 

Strike Release Time: 

1.

 

Enter Programming mode. 

 

2.

 

Press 

6

 to enter Menu 6. 

 

The left LED flashes green. 

 

Green 

Green 

Green  Green 

Содержание AYC-E 5 Series

Страница 1: ...AYC Ex5 T65 Series Convertible Backlit Proximity PIN Readers Controllers Installation and Programming Manual Ex5 Models AYC E55 AYC E65BB AYC E65BG AYC E65BW T65 Models AYC T65B AYC T65N AYC Ex5 AYC T65 ...

Страница 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Страница 3: ...er Operation 16 3 1 General 16 3 2 Programming as a Reader 17 3 2 1 Entering Programming Mode 18 3 2 2 Exiting Programming Mode 18 3 2 3 Selecting Keypad Transmission Format 19 3 2 4 Selecting Proximity Card Transmission Format 24 3 2 5 Changing the Programming Code 26 3 2 6 Changing the Facility Code 27 3 2 7 Setting the Backlight Behavior 27 3 2 8 Return to Factory Default Settings 28 3 2 9 Repl...

Страница 4: ...ing Mode 37 4 9 3 Changing Lock Strike Code 38 4 9 4 Changing Auxiliary Code 38 4 9 5 Changing the Programming Code 39 4 9 6 Changing the Normal Secure Code 40 4 9 7 Changing the Normal Bypass Code and Door Chime Settings 40 4 9 8 Setting Fail Safe Secure Operation Tamper Siren and Lock Strike Release Time 41 4 9 9 Defining the Auxiliary Input and Output 43 4 9 10 Setting the Lockout Feature 48 4 ...

Страница 5: ... Contents AYC Ex5 T65 Series Installation and Programming Manual v 4 9 17 Exiting Secure Mode if Normal Secure Code was Lost 60 5 Technical Specifications 61 A Declaration of Conformity 63 B Limited Warranty 64 ...

Страница 6: ...ation and Programming Manual List of Figures Figure 1 Drilling and Mounting Template 11 Figure 2 Controller Application Wiring Diagram 14 Figure 3 Controller Wiring Using the Internal Power 15 Figure 4 Controller Wiring Using the External Power 15 ...

Страница 7: ...amming Manual vii List of Tables Table 1 Wiring the Reader to the Controller 12 Table 2 Wiring the Unit as a Controller 13 Table 3 Reader Programming Menus 17 Table 4 Controller Programming Menu 36 Table 5 Quick Reference Guide for Auxiliary Mode Setting 43 ...

Страница 8: ...g future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained ...

Страница 9: ...ns as a secured controller As a controller the units accept up to 500 users and allow entry via a personal identification number PIN and or by presenting a proximity card The PIN code length for the controller has several options The PIN code length can be a set number of 4 5 or 6 digits or it can be a 4 to 8 digit code For information on how the unit functions as a reader see Chapter 3 For inform...

Страница 10: ...allation When functioning as a reader Compatible host controller not supplied UL listed access control unit such as model AC 215U When functioning as a controller Secured intelligent power supply such as the PC 25T PS A25T PS C25T or PS C25TU secure controllers The controller connects to the following Electric lock strike mechanism or a magnetic lock device which implements fail safe power to lock...

Страница 11: ... mounting the reader 2 1 Mounting Before starting select the location to mount the unit This location should be at shoulder height To mount the unit 1 Peel off the back of the self adhesive mounting label template and place it on the required mounting location 2 Using the template as a guide drill two holes of the size indicated on the template on the surface to mount the unit Figure 1 Figure 1 Dr...

Страница 12: ...e After application firmly hold the unit in place until the glue dries 2 2 Wiring The unit is supplied with a 6 conductor 150 cm 60 in pigtail with exposed wires coated with solder 2 2 1 Wiring the Unit as a Reader If you connect the unit to a standard access controlunit it automatically functions as a reader To connect the unit as a reader to a controller 1 Select the appropriate connections acco...

Страница 13: ...pply is recommended Attach the cable shield wire on the reader to an earth ground best or to a signal ground connection at the panel or power supply end of the cable This configuration is best for shielding the reader cable from external interference 2 2 2 Wiring the Unit as a Controller If you connect the unit to a Rosslare secured power supply it automatically functions as a controller To connec...

Страница 14: ... the secured power supply s cable by cutting the cable jacket back 3 2 cm 1 and strip the wire 1 3 cm 3 Splice the controller pigtail wires to the corresponding secured power supply s wires and cover each joint with insulating tape 4 Trim and cover all conductors not used 5 To connect the unit to the desired power supply option refer to the relevant wiring diagrams that follow Figure 2 shows the w...

Страница 15: ...ng Manual 15 Figure 3 shows the auxiliary output connection using the internal power Figure 3 Controller Wiring Using the Internal Power Figure 4 shows the auxiliary output connection using the external power Figure 4 Controller Wiring Using the External Power ...

Страница 16: ...resented proximity card or an entered PIN code Programming the reader is done via the unit s keypad driven programming menu system Section 3 2 Keypad data can be sent via one of eight keypad transmission formats For more information see Section 3 2 3 Rosslare proximity cards presented to the reader can output card data as Wiegand 26 Bit Clock Data and Wiegand PIN See Section 3 2 4 for more informa...

Страница 17: ...nu Description Default 1 Selecting Keypad Transmission Format Single Key Wiegand 6 Bit Rosslare Format Single Key Wiegand 6 Bit with Nibble Parity Bits Single Key Wiegand 8 Bit Nibbles Complemented 4 Keys Binary Facility Code Wiegand 26 Bit 1 to 5 Keys Facility Code Wiegand 26 Bit 6 Keys BCD and Parity Bits Wiegand 26 Bit 1 to 8 Keys BCD Clock Data 2 Selecting Card Transmission Format Wiegand 26 B...

Страница 18: ...he left LED turns off and the right LED turns red 2 Enter your 4 digit Programming code If the Programming code is valid the right LED turns green If the Programming code is invalid you hear a long beep and the reader returns to Standby mode If no key is pressed for 30 seconds while in Programming mode the unit returns to Standby mode 3 2 2 Exiting Programming Mode To exit Programming mode 1 Press...

Страница 19: ...nter Menu 1 The left LED turns red 3 Enter one of the following options 1 Single Key Wiegand 6 Bit Rosslare Format default 2 Single Key Wiegand 6 Bit with Nibble Parity Bits 3 Single Key Wiegand 8 Bit Nibbles Complemented 4 4 Keys Binary Facility Code Wiegand 26 Bit 5 1 to 5 Keys Facility Code Wiegand 26 Bit 6 6 Keys BCD and Parity Bits Wiegand 26 Bit 8 1 to 8 Keys BCD Clock Data Single Key When s...

Страница 20: ... first 3 bits and odd parity for the last 3 bits 0 1 1010 0 A in Hexadecimal 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1 1 1011 1 B in Hexadecimal 5 1 0101 0 0 1100 1 C in Hexadecimal Option 2 Single Key Wiegand 6 Bit Nibble and Parities Each key press immediately sends 4 bits with 2 parity bits added even parity for the first 3 bits and odd parity for t...

Страница 21: ...e a standard 26 bit card output The Facility code is set in Programming Menu number four and can be in the range 000 to 255 The factory default setting for the Facility code is 000 see Section 3 2 6 The keypad PIN code is 4 digit long and can range between 0000 and 9999 On the fourth key press of the 4 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format ...

Страница 22: ...s in length key must be pressed to signify the end of PIN code entry For keypad PIN codes that are 5 digits in length on the fifth key press of the 5 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If is pressed during PIN code entry or a PIN code greater than 65 535 is entered the keypad clears the PIN code entry buffer generates a ...

Страница 23: ...bits A The first key entered D Fourth key entered B Second key entered E Fifth key entered C Third key entered F Sixth key entered Option 8 1 to 8 Keys BCD Clock Data Buffers up to 8 keys and outputs keypad data without a Facility code like standard Clock and Data card output The keypad PIN code can be one to eight digits in length The PIN code length is selected while programming the reader for O...

Страница 24: ...red 3 Enter one of the following options 1 Wiegand 26 Bit 2 Clock Data 3 Wiegand Card PIN You hear three beeps The system returns to Standby mode 3 2 4 1 Proximity Card Transmission Formats Option 1 Wiegand 26 Bit In this mode 3 LSB bytes from the card serial number UID are transmitted in Wiegand 26 Bit format Two parity bits are added An even parity bit is sent first followed by three bytes of ca...

Страница 25: ...y or is not pressed within 5 seconds the keypad clears the card buffer and the PIN code entry buffer generates a medium length beep and be ready to receive a new card The keypad PIN code can be one to five digits in length in the range of 0 to 99 999 When entering a keypad PIN code must be pressed to signify the end of the PIN entry When pressing the data is sent by the Wiegand data lines If the k...

Страница 26: ...0 0000 0000 AAAA BBBB OP Where A The first key entered B Second key entered EP Even parity for first 12 bits OP Odd parity for last 12 bits 3 2 5 Changing the Programming Code The Programming code cannot be erased meaning the code 0000 is invalid and does not erase the Programming code The factory default 4 digit Programming code is 1234 To change the Programming code 1 Enter Programming mode 2 Pr...

Страница 27: ...s red 3 Enter the new 3 digit Facility code You hear three beeps The system returns to Standby mode 3 2 7 Setting the Backlight Behavior To set the backlight behavior 1 Enter Programming mode 2 Press 6 to enter Menu 6 The left LED turns red 3 Enter one of the following codes 0 for always off 1 for always on 2 for 10 sec backlight after a key is pressed otherwise off Transmit LED also off 3 for 10 ...

Страница 28: ...urn all codes to their factory default setting To return to factory default settings 1 Enter Programming mode 2 Press 0 to enter Menu 0 Both LEDs flash red 3 Enter your 4 digit Programming code If the Programming code is valid all memory is erased You hear three beeps and the reader returns to Standby mode If the Programming code is invalid you hear a long beep and the reader returns to Standby mo...

Страница 29: ...mming code is forgotten the unit can be reprogrammed in the field To replace a lost Programming code 1 Remove power from the reader 2 Activate tamper by removing the reader from the wall or removing the reader s case 3 Apply power to the reader 4 You now have 10 seconds to enter Programming mode using the factory default Programming code 1234 ...

Страница 30: ...es and or proximity cards Each user is provided with two code memory slots Memory Slot 1 Primary code and Memory Slot 2 Secondary code The PIN code length has several options The PIN code length can be a set number of 4 5 or 6 digits or it can be a 4 8 digits option When choosing the 4 to 8 digit option please note that you should either enter zeros before the code or press pound at the end for ex...

Страница 31: ... of operation by presenting the PIN code and or proximity card one time to the controller The Master user is convenient but is less secure than a Secure user 4 2 Modes of Operation There are three modes of operation 4 2 1 Normal Mode The left LED is green Normal mode is the default mode In Normal mode the door is locked until a Primary code is presented to the controller Special codes such as Lock...

Страница 32: ...right LED flashes green for 10 seconds during which the Secondary code must be entered A Master user only needs to present the code once to gain entry 4 2 4 Changing the Modes of Operation 4 2 4 1 Changing from Normal Mode to Secure Mode The default factory setting for the Normal Secure code is 3838 To change from Normal to Secure mode 1 Enter the Normal Secure code The left LED flashes red 2 Pres...

Страница 33: ...e To change from Normal to Bypass mode 1 Enter the Normal Secure code The left LED flashes orange 2 Press to confirm the mode change The left LED stops flashing 4 2 4 4 Changing from Bypass Mode to Normal Mode See Section 4 9 7 to create modify the Normal Bypass code To change from Bypass to Normal mode 1 Enter the Normal Secure code The left LED flashes green 2 Press to confirm the mode change Th...

Страница 34: ...iary settings 4 5 Internal Case and Back Tamper If the unit is forcibly opened or it is removed from the wall a tamper event is triggered A tamper output opens sending a signal to the connected alarm system purple wire The event closes when the tamper is closed case is re closed or re attached to the wall The tamper event can also activate the auxiliary output if the controller is in Auxiliary Mod...

Страница 35: ...ration From the moment the REX button is pressed the door is unlocked until the REX button is released plus the Lock Strike Release Time In this case the Lock Strike Relay only begins its count down once the REX button is released 4 8 Secured Intelligent Power Supply Rosslare s secured intelligent power supplies are designed for use with Rosslare s secured standalone access control units including...

Страница 36: ...menus as well as all the default factory codes and settings for the units Table 4 Controller Programming Menu Menu No Menu Description Default 4 digits 5 digits 6 digits 4 8 digits 1 Changing Lock Strike Code 2580 25802 258025 25802580 2 Change Auxiliary Code 0852 08520 085208 08520852 3 Changing Program Code 1234 12341 123412 12341234 4 Changing Normal Secure Code 3838 38383 383838 38383838 5 Cha...

Страница 37: ... mode To enter Programming mode 1 Press twice The left LED turns off and the right LED turns red 2 Enter your 4 digit Programming code The right LED turns green 4 9 2 Exiting Programming Mode To exit Programming mode 1 Press twice to exit Programming mode at any time You hear 3 beeps The left LED turns green and the right LED turns off Wrong entries reset the controller back to Normal mode While i...

Страница 38: ...ies returns the controller to Normal mode Code 0000 erases the Lock Strike Code 1 The factory default 4 digit Lock Strike code is 2580 To change the Lock Strike code 1 Enter Programming mode 2 Press 1 to enter Menu 1 The left LED turns red 3 Enter the new Strike Code 1 code You hear three beeps The system returns to Normal mode 4 9 4 Changing Auxiliary Code The Auxiliary code is mainly used as a m...

Страница 39: ... 2 Press 2 to enter Menu 2 The left LED turns orange 3 Enter the new Auxiliary code You hear three beeps The system returns to Normal mode 4 9 5 Changing the Programming Code Programming code cannot be erased meaning the code 0000 is not valid and does not erase the Programming code The factory 4 digit Programming code is 1234 To change the Programming code 1 Enter Programming mode 2 Press 3 to en...

Страница 40: ... Default Normal Secure code is 3838 To change the Normal Secure code 1 Enter Programming mode 2 Press 4 to enter Menu 4 The left LED flashes red 3 Enter the new Normal Secure code You hear three beeps The system returns to Normal mode 4 9 7 Changing the Normal Bypass Code and Door Chime Settings To change the Normal Bypass code and door chime settings 1 Enter Programming mode 2 Press 5 to enter Me...

Страница 41: ...ode and disable the door chime Enter a code not ending with 0 to enable the Bypass code and enable the door chime You hear three beeps The system returns to Normal mode 4 9 8 Setting Fail Safe Secure Operation Tamper Siren and Lock Strike Release Time The default value is 0004 which corresponds to Fail Secure operation no siren and a 4 second Lock Strike release time To set the Fail Safe Secure Op...

Страница 42: ...e 0 For Fail Safe Operation the first digit should be 1 Second digit Siren Time in minutes 1 9 0 disabled Third and fourth digits Enter the number of seconds from 1 to 99 that you want the Lock Strike to be released For example 0312 means a Fail Secure Operation consisting of a 3 minute siren and a 12 second Lock Strike release time You hear three beeps The system returns to Normal mode Green ...

Страница 43: ...ry Input The Auxiliary mode defines the function of the Auxiliary Input Third and fourth digits Auxiliary Setting Each of the Auxiliary modes has a 2 digit setting that affects how the Auxiliary mode functions Table 5 You hear three beeps The system returns to Normal mode Table 5 Quick Reference Guide for Auxiliary Mode Setting Aux Mode Aux Input Function Aux Output Activated by Aux Relay Aux Sett...

Страница 44: ...input function Activates the auxiliary output Auxiliary output activated by Valid user code Auxiliary code and Auxiliary input For example in Auxiliary Mode 0 the controller can function as a two door controller The auxiliary relay is to be attached to the lock on the second door The auxiliary setting defines the door open time for the second door The auxiliary input is to be attached to the REX p...

Страница 45: ...he auxiliary relay is to be activated The auxiliary input can switch the mode of operation of the controller between Normal and Secure modes By connecting a switch timer or alarm system output to the auxiliary input the controller can be automatically switched from Normal mode during office hours to Secure mode after office hours 4 9 9 4 Auxiliary Mode 3 Auxiliary input function Toggles Normal Sec...

Страница 46: ...or The auxiliary relay is wired to the alarm system Without a valid code entered the auxiliary relay matches the condition of the magnetic contact switch if the door opens the auxiliary relay opens if the door closes the auxiliary relay closes When a valid code is entered a countdown for maximum shunt time as defined by the auxiliary setting begins if the door is not closed before the maximum shun...

Страница 47: ...auxiliary setting defines the door ajar time 4 9 9 9 Auxiliary Mode 8 This mode controls the door indicator right LED The right LED is not lit when A valid code is entered While in Secure mode when waiting for Secondary code Auxiliary input function Green LED control Auxiliary output activated by Valid user code Auxiliary code For example in Auxiliary Mode 8 the controller can function as a 2 door...

Страница 48: ...t is open the right LED flashes red if the auxiliary input is closed the right LED flashes green 4 9 10 Setting the Lockout Feature If the controller is presented with wrong codes PIN or card consecutively several times the unit goes into Lockout mode When a lockout occurs the controller keypad and reader are locked so no codes can be entered until the set lockout period expires During Lockout the...

Страница 49: ... in 0 to 990 seconds 4 9 11 Setting the Backlight Behavior The controller allows you to define the way the unit s backlight works To set the backlight behavior 1 Enter Programming mode 2 Press 6 to enter Menu 6 The left LED flashes green 3 Enter one of the following codes 5000 Backlight off 5100 Backlight on default 5200 Backlight is off activates for 10 seconds when a key is pressed after which i...

Страница 50: ...enrolled to a user slot that already has a Primary code enrolled but has no Secondary code Secondary codes do not have to be unique meaning multiple users can all hold the same Secondary code Secondary codes cannot be the same as any system codes such as the Normal Secure or Lock Strike codes Users who hold Secondary codes can gain entry in any mode of operation 4 9 12 3 Enrolling Methods There ar...

Страница 51: ...e 3 Enter the 3 digit user slot number between 001 and 500 that you wish to enroll a Primary or Secondary code to For example User Slot 003 represents User 3 If the selected slot has no Primary code the left LED flashes green indicating that the controller is ready to accept a Primary code If the selected slot already has a Primary code but no Secondary code the left LED flashes red indicating tha...

Страница 52: ...r to Step 3 for the slot to which you want to assign a code 5 Do one of the following Press to move to the next available user slot number Enter another 3 digit user slot number If you do not wish to continue enrolling codes press twice and the controller returns to Normal mode 4 9 12 5 Enrolling Secondary Codes using Search Method The Code Search feature enables you to quickly enroll a Secondary ...

Страница 53: ...es red If the Primary code entered is not valid you hear a long beep and the unit continues to wait for a valid Primary code 5 Perform one of the following Enter the 4 to 8 digit code to be used as the Secondary code Present the user card to be used as the Secondary code If the Secondary code is valid the controller beeps three times and returns to Normal mode If the Secondary code is invalid the ...

Страница 54: ...er slots are empty and which user slots are not 4 9 13 1 Deleting Primary and Secondary Codes using Standard Method To delete the Primary and Secondary codes using the Standard Method 1 Enter Programming mode 2 Press 8 to enter Menu 8 The left LED turns red and the right LED turns orange 3 Enter the 3 digit User Slot code you wish to delete The left LED flashes red indicating the controller is wai...

Страница 55: ...rch Method To delete the Primary and Secondary codes using the Code Search Method 1 Enter Programming mode 2 Press 8 to enter Menu 8 The left LED turns red and the right LED turns orange 3 Enter 000 as the 3 digit user slot number The right LED flashes orange 4 Perform one of the following Enter the 4 to 8 digit PIN code of the Primary code belonging to the user you want to delete Present the user...

Страница 56: ... Strike relay However different user codes may be set to operate the auxiliary relay instead or operate both the Lock strike and auxiliary relay Assignment of such codes is achievable for any valid user code entered in the controller There are two methods to assign relay codes to users a standard method and a search method 4 9 14 1 Relay Code Assignment using Standard Method To assign relay code u...

Страница 57: ...now waiting for another slot number 5 Do one of the following Press to move to the next available user slot number Enter another 3 digit user slot number If you do not wish to continue enrolling codes press twice and the controller returns to Normal mode 4 9 14 2 Relay Code Assignment using Search Method To assign relay code using the Search method 1 Enter Programming mode 2 Press 9 to enter Menu ...

Страница 58: ...r you want to delete The left LED flashes green 5 Enter the assignment digit for the current user slot 1 activates the Lock Strike relay only default 2 activates the Auxiliary relay only 3 activates the Lock Strike and Auxiliary relays If the assignment digit is valid three beeps are heard and the controller returns to Normal mode If the assignment digit is invalid a long beep sounds and the contr...

Страница 59: ...ns to factory defaults and sets a 6 digit code 08 Returns to factory defaults and sets a 4 to 8 digit code Both LEDs flash red 3 Enter your 4 digit Programming code If the Programming code is valid all memory is erased You hear three beeps and the controller returns to Normal mode If the Programming code is invalid you hear a long beep and the controller returns to Normal mode without erasing the ...

Страница 60: ...l Secure Code was Lost The unit must be in Secure mode otherwise this does not work Make sure that the left LED is red before proceeding To exit Secure mode if Normal Secure Code was lost 1 Remove power from the power supply unit 2 Press the REX button on the power supply unit 3 Apply power to the unit with the REX button pressed 4 Release the REX button 5 You now have 10 seconds to exit Secure mo...

Страница 61: ... Input Dry contact N O Tamper Output Open collector active low 30 mA max sink current Cable Distance to Host Controller Up to 500 ft 150 meters using an 18 AWG cable Max Proximity Card Read Range N A 40 mm 1 6 in Proximity Card Modulation N A ASK at 125 kHz Proximity Card Compatibility N A EM cards Card Transmit Format Reader N A Wiegand 26 Bit or Clock Data Keypad Transmit Format Reader Programma...

Страница 62: ... Temp Range 30 C to 65 C 22 F to 150 F Operating Humidity Range 0 to 95 non condensing Outdoor Usage Weather resistant meets IP68 epoxy potted suitable for outdoor use Physical Characteristics Size Height x Width x Depth 155 x 44 x 6 5 mm 6 1 x 1 7 x 0 3 in 155 x 44 x 9 mm 6 1 x 1 7 x 0 4 in 121 x 70 x 8 mm 4 8 x 2 8 x 0 3 in Weight 120 g 4 2 oz 143 g 5 0 oz 121 g 4 3 oz ...

Страница 63: ...tal device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfere...

Страница 64: ...anual B Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Страница 65: ...05 0069 support na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electron...

Отзывы: