Rosslare AY-Z12 Скачать руководство пользователя страница 13

Limited Warranty

 

AY-Z12 Installation Manual  

Page 12 

 

Exclusions and Limitations  

ROSSLARE shall not be responsible or liable for any damage or loss resulting from the 
operation or performance of any Product or any systems in which a Product is 
incorporated. This warranty shall not extend to any ancillary equipment not furnished by 
ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product 
that is used with any ancillary equipment, which is not furnished by ROSSLARE. 
This warranty does not cover expenses incurred in the transportation, freight cost to the 
repair center, removal or reinstallation of the product, whether or not proven defective.  
Specifically excluded from this warranty are any failures resulting from Customer's 
improper testing, operation, installation, or damage resulting from use of the Product in 
other than its normal and customary manner, or any maintenance, modification, alteration, 
or adjustment or any type of abuse, neglect, accident, misuse,  improper operation, normal 
wear, defects or damage due to lightning or other electrical discharge. This warranty does 
not cover repair or replacement where normal use has exhausted the life of a part or 
instrument, or any modification or abuse of, or tampering with, the Product if Product 
disassembled or repaired in such a manner as to adversely affect performance or prevent 
adequate inspection and testing to verify any warranty claim. 
ROSSLARE does not warrant the installation, maintenance, or service of the Product.  
Service life of the product is dependent upon the care it receives and the conditions under 
which it has to operate.  
In no event shall Rosslare be liable for incidental or consequential damages.  

 

Limited Warranty Terms  

THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD

.

 AND 

IT

S SUBSIDIARY

'

S WARRANTY

 

THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON

,

 WHETHER OR 

NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE

.

 

 

THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES

.

 ALL OTHER 

WARRANTIES EXPRESSED OR IMPLIED

,

 INCLUDING WITHOUT LIMITATION

,

 IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE

,

 ARE 

SPECIFICALLY EXCLUDED

IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE 

PURCHASE PRICE OF THE PRODUCT

,

 OR FOR ANY OTHER INCIDENTAL

,

 

CONSEQUENTIAL OR SPECIAL DAMAGES

,

 INCLUDING BUT NOT LIMITED TO LOSS OF 

USE

,

 LOSS OF TIME

,

 COMMERCIAL LOSS

,

 INCONVENIENCE

,

 AND LOSS OF PROFITS

,

 

ARISING OUT OF THE INSTALLATION

,

 USE

,

 OR INABILITY TO USE SUCH PRODUCT

,

 TO 

THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW

THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE 

PROVISIONS OF THIS LIMITED WARRANTY

.

 

 

 

Содержание AY-Z12

Страница 1: ...Long range Multi Reader AY Z12 Installation Guide May 2009 ...

Страница 2: ......

Страница 3: ...f Contents 1 Introduction 3 2 Technical Specifications 5 3 Installation 6 3 1 The Installation Kit 6 3 2 Installing the AY Z12 Long Range Reader 6 4 Wiring Instructions 9 5 Operation Instructions 10 Appendix A Limited Warranty 11 Appendix B Technical Support 13 ...

Страница 4: ...Reader is an RFID proximity card reader utilized with access control systems Figure 1 The AY Z12 Long Range Reader This Manual contains the following information Installation Wiring Instructions Operation Instructions Page 3 AY Z12 Installation Manual ...

Страница 5: ...lled professionally This product has only one available channel Pursuant to FCC 15 21 54 FR 17714 Apr 25 1989 as amended at 68 FR 68545 Dec 9 2003 changes or modifications made to equipment which are not expressly approved by Rosslare Enterprises Ltd may void the user s authority to operate the equipment ...

Страница 6: ...ent 30mA Maximum Cable Distance to Controller 500 ft 150 meters Card Read Distance Weigand 26 output format with a 23 6 60 cm maximum read range Environmental Characteristics Operating Temp Range 22 F to 145 F 30 C to 63 C Operating Humidity 0 95 non condensing Suitable for outdoor use IP54 Dimensions Height x Width x Depth 11 81 x 11 81 x 1 0 300mm x 300mm x 25 4 mm Weight 2 35 Lbs 1066g Measured...

Страница 7: ...omprises of the following items that are to be used during the installation procedure One Installation Template Four pan head screws wall plugs One L shaped security screw tool Three Security screws 3 2 Installing the AY Z12 Long Range Reader AY Z12 Installation Manual Page 6 ...

Страница 8: ...st be mounted with the appropriate screws not supplied as described in the template provided Installing the unit on metal surfaces will reduce the read range considerably to decrease the affect of the metal surface use Rosslare s MP Z02 Spacer sold separately as described in the image below for a max range of 43cm 17 inch Figure 3 Installing the unit with the MP Z02 spacer Page 7 AY Z12 Installati...

Страница 9: ...ocation 3 Using the template as a guide drill the holes the size of which are indicated in the template to install the Reader or spacer onto the surface 4 Drill a 7 16 10mm hole for the cable In the event that you are installing the reader on metal place a grommet or electrical tape around the edge of the hole and use the MP Z02 spacer 5 Route the interface cable from the Reader to the Controller ...

Страница 10: ...ple wire to the correct input on the Controller Reader Color Weigand Output 10 16 VDC Red DC Input Shield Ground Black Ground Data 1 White Data 1 Data 0 Green Data 0 LEDCTL Brown LED Control Tamper Purple Tamper 4 Trim and cover all unused conductors Note The individual wires from the Reader are color coded according the Wiegand standard When using a separate power supply for the Reader this suppl...

Страница 11: ...ing properly The LED returns to its idle state red 2 Present the appropriate type of proximity card to the Reader The LED will flash green briefly and a short beep is emitted thus indicating that the card was read properly The Reader transmits the card s data to the Controller the Controller checks the data if the card transmission is valid the LED can change briefly to green Refer to the Controll...

Страница 12: ...is warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLAR...

Страница 13: ...he Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be li...

Страница 14: ... States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buenos Aires Argentina T...

Страница 15: ......

Страница 16: ...0706 0960127 02 www rosslaresecurity com ...

Отзывы: