Operation Instructions
AY-Z12 Installation Manual
Page 10
5.
Operation Instructions
The Reader should be tested after wiring it to a power supply and
the Controller.
To test the Reader:
1.
Power up the Reader. The LED flashes green on power up (it
may flash orange), and the Beeper sounds twice, at which
point it begins an auto-calibration procedure, this can take
up to two seconds, when the calibration is complete a third
beep will sound, thus indicating that the Reader is working
properly. The LED returns to its idle state (red).
2.
Present the appropriate type of proximity card to the
Reader. The LED will flash green briefly and a short beep is
emitted, thus indicating that the card was read properly.
The Reader transmits the card's data to the Controller; the
Controller checks the data, if the card transmission is valid, the
LED can change briefly to green. Refer to the Controller’s
description of LED operation for Controllers with Reader LED
control. The LED then returns to its idle state (red)
The range is measured using a Rosslare Proximity Card (P/N AT-
11/12) or equivalent. The range also depends on electrical
environment and/or proximity to metal.