Electrical Characteristics
Operating Voltage Range
Typical: 9 to 15 VDC (2 A)
Max: 24 VDC
Input Current
Standby: 0.2 A max
Read: 1.2 A max
Credential Read Distance*
AY-U915BT: 0.5 to 6 m (1.6 to 19.7 ft)
(adjustable)
AY-U920BT: 0.5 to 12 m (1.6 to 39.4 ft)
(adjustable)
Transmission Protocol
Wiegand 26-Bit (default)
Wiegand 32-Bit
Wiegand 34-Bit
Wiegand 40-Bit
Wiegand 56-Bit
Wiegand 64-Bit
OSDP**
Custom
Maximum Cable Distance
150 m (492 ft) with 18” AWG cable
Frequency
AY-U9xxBT-US: 902–928 MHz (America)
AY-U9xxBT-EU: 865–868 MHz (Europe)
Modulation Type
ASK
Read Sensitivity
Dual polarization read mode
Cards and Tags
•
EPC GEN2 (ISO18000-6C) tags
•
BLE-ID soft credentials
Note:
That the reader is only compatible
with Rosslare’s credentials.
* Measured using a Rosslare proximity card or equivalent.