background image

AY-H6255BT 

 

CSN SMART™ Smart Card Readers (Rev. A) 

Installation and User Manual

 

1.

 

Introduction 

The CSN SMART™ AY-H6255BT is an innovative reader that lets 

cardholders use smartphone apps as credentials in access control 
systems by BLE ID and NFC ID compatible apps. The unit features three 

technologies: a built-in CSN smart card (13.56 MHz) reader, an NFC ID 
reader, and a Bluetooth BLE ID reader mode that supports BLE ID 

transmitted by both Android and iOS smartphone apps. 
The following list shows the credential technologies for which we have 
confirmed compatibility: 

 

ISO14443A – MIFARE® Ultralight® Nano / EV1/ C, MIFARE 
Classic® / Classic EV1, MIFARE Plus® S / SE / X / EV1, MIFARE 

DESFire® EV1 / EV2, N-TAG NFC / Card Emulation 

 

ISO15693 – HID® iClass®, PicoPass, iCode, LEGIC 

 

ISO18092 – SONY® FeliCa® (Hong Kong Octopus) 

 

Rosslare’s CS-ECA NFC app (HCE) for Android smartphones 
Scan the QR code to download Rosslare’s NFC app. 

 

Android app and BLE ID for Android and iPhone 

 

This list is continuously updated. For the latest compatibility list, 

contact your sales representative 

The standard reader outputs the Wiegand CSN data in Wiegand 26-Bit 

format. Other Wiegand formats are selectable using the 

CS-CCT 

Configuration Card Tool for the DR-6255 application. 

1.1

 

Installation Kit 

The installation kit consists of the following items to be used during 
the installation procedure: 

 

1 self-adhesive mounting label template 

 

2 mounting screws and 2 screw anchors 

 

1 Torx key tool 

 

1 Torx security screw 

Figure 1: AY-H6255BT 

 

 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Power Supply Type 

Regulated 

Operating Voltage Range 

8 to 16 VDC 

Current @ 12 V 

Standby: 110 mA, max: 185 mA 

Bluetooth BLE Read Range 

From 1 m to 10 m (3.2 to 32.5 ft) (line of sight) 

RFID and NFC Read 
Range* 

5 cm to 10 m (2.0 to 3.9 in.) 

LED/Buzzer Controls 

Dry Contact, N.O. 

Tamper Output 

Open collector, active low, max. sink current 

16 mA 

Maximum Cable Distance 
to Controller 

Wiegand: 150 m (500 ft) with 18-AWG cable 
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 
18-AWG twisted shielded cable 

*  Measured using a Rosslare MIFARE Classic EV1 (ISO card). Read range with 

other credential technologies may vary. Range also depends on electrical 

environment and proximity to metal. 

2.2

 

Environmental Characteristics 

Operating Temp. Range 

-35°C to 66°C (-31°F to 150°F) 

Operating Humidity Range 

0 to 95% (non-condensing) 

Outdoor Usage 

Weather-resistant, UV-resistant, meets IP65, 

epoxy-potted, suitable for indoor and outdoor 
use 

2.3

 

Physical Characteristics 

Dimensions 
(H x W x D) 

110.7 x 75.0 x 17.0 mm (

4.4 x 3.0 x 0.7

 in.) 

Weight 

177 g (6.2 oz) 

3.

 

Wiring 

The units are supplied with a 10-conductor 5-m (16-ft) pigtail with 

exposed wires coated with solder. 
To connect the reader to the controller: 
1.

 

Select the appropriate connections according to Table 1. 

2.

 

Prepare the controller cable by cutting its jacket back about 3 cm 

(1¼") and strip the insulation from the wires about 1.3 cm (½"). 

3.

 

Splice the reader’s pigtail wires to the corresponding controller 

wires and cover each joint with insulating tape. 

4.

 

If the tamper output is being utilized, connect the purple wire to 

the correct input on the controller. 

5.

 

Trim and insulate the ends of all unused conductors individually. 
Do not short any unused wires together. 

 

 

The individual wires from the reader are color coded according the 

Wiegand standard. 

 

When using a separate power supply for the reader, this supply and 
that of the controller must have a common ground. 

 

The reader’s cable shield wire should be preferably attached to an 
earth ground, or a signal ground connection at the panel, or power 

supply end of the cable. 

Table 1: Wiring 

Wire Color 

Function 

Red 

Power 

Black 

Ground 

Green 

Data 0 / Data 

White 

Data 1 / Clock 

Orange 

Green LED Control* 

Brown 

Red LED Control* 

Purple 

Tamper Output 

Yellow 

Buzzer Control* 

Blue 

RS-485 – A / OSDP** 

Gray 

RS-485 – B / OSDP** 

*  These wires have programmable functions that may be adjusted by presenting 

a configuration card within 10 seconds upon powering on the unit. See the 

CS-CCT Configuration Card Tool for the DR-6255 Software Manual

 for how 

you can create a configuration card. 

** RS-485 is used for firmware update. 

Отзывы: