Wiring Diagrams
Page 10
07/04
AC-F43
(-)
ELECTRIC LOCK
STRIKE
COM
N.C.
N.O.
REX / BL
LOCK
V IN
R
E
X
/
B
L
(-)
(-)
(+)
(+)
FAIL SAFE
or
FAIL SECURE
R
E
X
COMMON
POWER SUPPLY
12V - 24V DC
or
16V - 24V AC
FROM TRANSFORMER
{
GROUND
BLACK
RED
GREEN
GRAY
BROWN
PURPLE
AC-F43
Transorb: 1.5
KE
47
C
- Connect to load terminals
(Optional transorb, Not Supplied)
07/04
Page 11
AC-F43
Wiring the Auxiliary Input and Output
IN / MONITOR
V IN
COMMON
POWER SUPPLY
(-)
(+)
12V - 24V DC
or
16V - 24V AC
FROM TRANSFORMER
Auxiliary
Load
AUXILIARY
INPUT
(MONITOR)
(-)
A
U
X
.
IN
IN
/
M
O
N
IT
O
R
COM
N.C.
N.O.
AUX.
{
GROUND
BLACK
RED
WHITE
YELLOW
ORANGE
BLUE
AC-F43
Transorb: 1.5
KE
47
C
- Connect to load terminals
(Optional transorb for inductive loads, Not Supplied)