Programming the AF-G43
Programming the AC-F43 is done solely via the unit's keypad driven
Programming Menu System. To reach the Programming Menu
System the AC-F43 must first be placed into Programming Mode.
See "Entering Programming Mode" on Page 21 for more
information.
During the AC-F43's manufacturing process certain codes and
settings are pre-programmed. These settings are the called the
"Default Factory Settings".
The table below shows the names of all the AC-F43 Menus. It also
shows of all the AC-F43's default factory codes and settings.
Programming Menu
2580
Change Open Code 1
1
0852
Change Auxiliary Code
2
1234
Change Program Code
3
3838
Change Normal / Secure Code
4
Change Normal / Bypass Code
5
0004
Change Lock Strike Release Time
6
2004
Define Auxiliary Inputs / Outputs
Enroll PIN Code.
7
Delete PIN Code
8
Code Assignment with Strike/Auxiliary
9
Return to Default Factory Setting
0
You will find a complete description and instructions for each of the
above menu items on the following pages.
Page 20
07/04
AC-F43
Menu Description
Factory
Settings
Menu
Number
Page 21
07/04
Entering Programming Mode
Exiting Programming Mode
1)
Press the
"#"
key two times
within 2 seconds.
!
Mode LED will turn off
!
Door LED will turn red
2)
Enter your 4-digit Programming
Code.
If the Programming Code
is valid the door LED will turn
green and the AC-F43 will be in
Programming Mode.
Note:
- The AC-F43 must be in Normal Mode to enter the
Programming Mode.
- The factory default Programming Code is 1234
- If a Programming Code is not entered within 5 seconds,
the AC-F43 will return to Normal Mode.
1)
To exit the Programming Mode at any time:
Press the
"#"
key
!
You will hear 1 long beeps.
!
The Door LED will be off
!
The Mode LED will turn green
This indicates that the AC-F43 has returned to Normal Mode.
2)
Wrong entries may reset the controller back to Normal Mode.
3)
While in Programming Mode if no key is pressed for 1 minute the
AC-F43 will exit programming mode and return to Normal Mode.
4)
While in enrolling user, deleting users, or code assignment
modes, to exit Progrmming Mode press the "#" key two times.
AC-F43
Mode
Door
Mode
Door
GREEN
RED
1
2
3
4
Mode
Door