ELECTRICAL SPECIFICATIONS
Enclosure SMPS
Input: 100 to 240 VAC, 1.6 A, 50–60 Hz, switch mode
power management board
C13 power cord
Output: 12 VDC, 4 A
PCBA Input Power
15 VDC, 2 A, regulated power management board
Backup Battery (sold
separately)
12 V sealed lead acid (SLA) up to 7 Ah, IEC62133
Relay Outputs
5 A DC, 150 W maximum
Auxiliary Outputs
12 VDC, 1.2 A typical (1.5 A max.)
Fuse
250 V, 2.5 A
OPERATIONAL SPECIFICATIONS
Relays 5 A, Form-C
6
Supervised Inputs
12
Readers (Wiegand Format)
4
Readers (OSDP Format)
2
Expansion Ports
1
Connectivity
TCP/IP, OSDP
OPERATIONAL SPECIFICATIONS (AC-825IP only)
Capacity
Up to 100,000 users
History Event Log Size
Up to 500,000 entries
Time Zones and Groups
256 multi-segment time zones,
64 holidays – each holiday can be multiple days
Practically unlimited amount of access groups
Special Features with
AxTraxNG
Interlock, first-person delay, auto-relock, scheduled
outputs operation,
4 programmable site codes, extended unlocked time,
fully interconnectedness, car parking management,
antipassback (per reader, between readers)
Security Modes
Normal and Secure
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range
-5°C to 50°C (23°F to 122°F)
Storage Temp. Range
-25°C to 50°C (-13°F to 122°F)
Operating Humidity Range
0 to 85% (non-condensing)