ADDITIONAL PRECAUTIONS 

WELDING OPERATIONS: 



 In environments with increased risk of electric shock; 



 In confined spaces; 



 In the presence of flammable or explosive materials; 

 

MUST BE evaluated in advance by an “expert supervisor” and must always be 

carried out in the presence of other people trained to intervene in emergencies. 

 

POSITION and HANDLING 

Position the welding machine on a horizontal surface that is able to support the 

weight: otherwise (e.g. inclined or uneven floors etc.) there is danger of over-

turning. 

 

The welder MUST NOT be supported by the operator (e.g using belts). 

The operator MUST NOT BE ALLOWED to weld in raised positions unless safety 

platforms  are used. 

 
 

VOLTAGE BETWEEN ELECTRODE HOLDERS OR TORCHES

:

 

Working with more than one welding machine on a single piece or on pieces that 

are connected may generate a dangerous accumulation of no-load voltage be-

tween two different electrode holders or torches, the value of which may reach 

double the allowed limit. 

IMPROPER USE: 

It is hazardous to use the welding machine for any work other than that for 

which it was designed.  Example  do not use  this welder for  pipe thawing. The 

safety guards and moving parts of the covering of the welding machine and of 

the wire feeder should be in their proper positions before connecting the welding 

machine to the power supply. 

 

WARNING! 

Any manual operation carried out on the moving parts of the wire feeder, for 

example: 



Replacing rollers and/or the wire guide; 



Inserting wire in the rollers; 



Loading the wire reel; 



Cleaning the rollers and the area underneath them.  

 

Should be carried out with the welding machine switched off and disconnected 

from the power supply outlet . Never lift the welding machine when connected to 

the mains supply. 

Содержание RXT100P

Страница 1: ...on warnings and cautions Failure to comply with instructions could result in personal injury and or damage to product or property Please retain instructions for future reference 100 Amp Gasless Mig We...

Страница 2: ...nuous MOG welding of carbon or mild steels without protective gas using appropriate cored tubular electrode wire Power for the arc is given by a single phase transformer with a drooping characteristic...

Страница 3: ...long period Do not touch the weld or the work piece unless you are wearing welding gloves Always use pliers or tongs Never touch the welded material with bare hands until it has been allowed to cool W...

Страница 4: ...okers or peo ple just passing by Use screens if necessary or non reflecting curtains KEEP CHILDREN AND ANIMALS AWAY Do not let children or animals have access to the welding equipment or to the work a...

Страница 5: ...n a single piece or on pieces that are connected may generate a dangerous accumulation of no load voltage be tween two different electrode holders or torches the value of which may reach double the al...

Страница 6: ...n materials cleaned with chlorinated solvents or near such substances Remove all flammable materials e g wood paper rags etc from the working area WARNING Do not weld on containers or piping that cont...

Страница 7: ...74 6 Caution Read operator s manual Ground Single phase transformer 1 50Hz Mains supply single phase A C 50 Hz RCM Marking indicating compliance to relevant Australian standards Mig Welding x Duty Cyc...

Страница 8: ...the switch according to the metal thickness 3 Wire speed adjustment knob Adjust this knob to set the wire feeding speed 4 Earth cable Use earth clamp to connect earth cable with work piece 5 Welding...

Страница 9: ...ed about 30cm of the wire through the guide tube and into the wire liner by hand The wire feed roller has two different size groves Check that the wire is aligned with the correct size grove in the wi...

Страница 10: ...ycle of the machine is exceeded the thermostatic protection will activate To commence the welding process proceed as follows Make sure that the earth clamp is firmly connected to the Work piece Select...

Страница 11: ...is changed clean out the wire guide and check the wire liner for build up of dust and other contaminants This increases friction and can lead to erratic wire feed and jamming Replace when necessary Da...

Страница 12: ...the wire tension adjustment nut No back tension on reel Check the wire spool clip Wire is oxidised Replace wire spool Re place liner 3 Poor weld pene tration Low input voltage Check that if input volt...

Страница 13: ...n 2 Wire feed assy 19 Wire feed control PCB 4 Wire spool holder 28 Weld current switch 27 Mains switch 29 Mains Cable 18 Handle 23 Earth lead 24 Torch assy 24 Mains switch 8 Fan Blade 3 Aux Transforme...

Страница 14: ...parts or at our discretion replace the unit free of charge This guarantee does not cover defects caused by or resulting from misuse abuse or ne glect trade professional or hire use repairs attempted b...

Страница 15: ...Page 15 RXT100P...

Отзывы: