![Ross RXT100P Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ross/rxt100p/rxt100p_general-instruction_1489062012.webp)
Page 12
RXT100P
N
o.
Breakdown Analysis
Solutions
1
No current output
No voltage input
Check the fuse and or cir-
cuit breaker
Wrong Fuse or breaker rating
Replace with correct rating
fuse or breaker
Thermal over load lamp lit
Allow the unit to cool
2
Bad wire feed
Low wire feed pressure
Tighten the wire tension
adjustment nut
No back tension on reel
Check the wire spool clip
Wire is oxidised
Replace wire spool. Re-
place liner
3
Poor weld pene-
tration
Low input voltage
Check that if input voltage
is the same with rated
voltage
Bad connection
Check grounding cable/
clamp, make sure of a
good connection.
Contact tip worn
Replace contact tip
4
No wire feed
Control wire broken or Faulty
switch in the handle
Check by inspection
Wire Control PCB faulty
Replace the PCB
TROUBLE SHOOTING GUIDE