background image

6

WARNING! 

LOW OR NO MAINTENANCE OF THE BATTERY.

Charge these types of battery slowly and keep on checking the voltage at the battery terminal 

with a multimeter.  When the voltage reaches 14.4 Volts for a 12 Volt battery or 28.8 Volt for a 

24 volt battery. STOP the charging.

END OF CHARGE

When charging is completed  turning the mains switch in off position and disconnect the 

mains cable from the mains plug. Disconnect the charging clamps from the battery terminals 

and put the battery charger in a dry place. Refit  the caps of the battery

STARTING

WARNING! 

THE STARTING FUNCTION MUST ONLY BE USED WHEN THEN A BATTERY DOES  

NOT HAVE ENOUGH ENERGY TO MAKE THE STARTER MOTOR ROTATE. 

WARNING: 

THE USE OF THE STARTER FUNCTION ON SOME VEHICLES MAY DAMAGE THE 

ELECTRICAL SYSTEM. PLEASE CHECK WITH THE VEHICLE MANUFACTURER AND VEHICLES' 

HAND BOOK BEFORE  USING. THE OPERATOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED 

TO THE VEHICLE.

To use the start function:

Ensure that the power to the charger is switched OFF

Connect the positive charging lead to the appropriate output terminal on the charger for the 

type of battery to be charged ie 12 or 24 volt

Connect the red clamp to the positive terminal (+) of the battery and the black clamp to the 

negative terminal (-).  

WARNING! 

IF THE CLAMPS ARE CONNECT THE WRONG WAY SERIOUS DAMAGE TO THE 

VEHICLES' ELECTRICAL SYSTEM MAY RESULT.

SET the mode / charge switch to 

Turn the charger ON

Start the vehicle immediate with the following procedure. 

  

START 3 Seconds ON, 120 Seconds OFF, 5 CYCLES MAXIMUM 

When the vehicle starts, turn OFF the charger and disconnect the charging clamps. 

WARNING! 

THE STARTING OPERATION MUST FOLLOW STRICTLY THE CYCLES WORK/

PAUSE INDICATED ON THE STARTER. FAILING TO FOLLOW THIS WILL RESULT IN THE MAIN 

IN LINE FUSE BLOWING 

AND WILL VOID THE WARRANTY OF THE CHARGER.

NOTE: 

IF THE VEHICLE DOES NOT START, THEN BOOST CHARGE THE BATTERY FOR 10 TO 

15 MINUTES TO MAKE STARTING EASIER 

Содержание RBC220

Страница 1: ...information warnings and cautions Failure to comply with instructions could result in personal injury and or damage to product or property Please retain instructions for future reference 1 BATTERY CHARGERS ROSSCHARGERS RBC220 RBC400 RBC320 RBC520 RBC620 ...

Страница 2: ...r acteristic W bend see the DIN41774 norm MODEL RBC220 RBC400 RBC320 RBC520 RBC620 INPUT VOLTAGE 240V 15A 240V 15A 240V 15A 240V 15A 240V 15A MAX CHARGE CURRENT AMPS 20 40 30 50 60 MAX START CURRENT AMPS 120 180 180 360 540 RATED OUPUT VOLTAGES DC 12 24 12 24 12 24 12 24 12 24 CHARGE RATE SETTINGS 3 3 4 6 6 AMP HOURS RECOM MENDED 20 400 20 400 20 400 20 800 20 1000 WEIGHT KG 11 5 14 5 15 5 25 26 S...

Страница 3: ...r rain Do not use near flammable gases or liquids Keep work area clean Clothing Avoid wearing loose clothing or jewellery to prevent these from touching the battery or charger Look after the charger When not in use store in a dry high place or keep locked up out of children s reach Use the charger only for its intended purposes Protect the Cables Do not carry the charger by the cable or pull the c...

Страница 4: ...s disconnected Never use the battery charger inside the car or on the bonnet Strictly follow the instructions of vehicles manufacturers for the use of battery chargers before using the charger TYPES OF BATTERIES These chargers are only suitable for Lead Acid batteries with an amp hour capacity not less than 20 Ah and should not be used to recharge Gel Cells NICAD NI Mh or any other type of battery...

Страница 5: ...rged battery 1 14 Flat battery Check that the charger is turned off and is disconnected for mains supply Connect the posi tive charging lead to the appropriate output terminal on the charger for the type of battery to be charged ie 12 or 24 volt CHARGING Connect the red clamp to the positive terminal of the battery and the black clamp to the negative terminal Select the mode switch to the charge p...

Страница 6: ...RATOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE VEHICLE To use the start function Ensure that the power to the charger is switched OFF Connect the positive charging lead to the appropriate output terminal on the charger for the type of battery to be charged ie 12 or 24 volt Connect the red clamp to the positive terminal of the battery and the black clamp to the negative terminal WARNING IF THE C...

Страница 7: ...charging switch positions 4 5 and 6 on these models are for boost charging the battery Then any of these positions are selected the charge timer is activated The charge timer can then be set to boost charge time up to 60 minutes Charge switch Timer ...

Страница 8: ...he warranty begins from the original date of purchase notwithstanding any subsequent repair or parts replacement Purchaser shall be responsible for all transport charges to and from the Authorised Service Centre Damage in transit is not covered by this warranty The purchaser should remove from the product any liquids if applicable before sending the tool for service or repair Any accessories shoul...

Отзывы: