background image

 

RAAC2/24 and RAAC2.5/36       

 

 

 

4  

 

Secure the Work Piece 

Wherever possible secure the work piece using clamps or a vice. It is safer than using your hand 
and leaves both hands free to control the air tool. 

 

Do Not Over-reach 

 

Do not over-reach, keep proper footing and maintain your balance at all times.  

Maintain Tools with Care 

 

Keep cutting tools sharp and clean for better and safer performance. Follow the instructions for 
lubricating and changing accessories. Check the tool power cord periodically and if damaged 
have it replaced by an authorised service facility.  Keep handles dry, clean and free from oil and 
grease. Ensure that ventilation slots are kept clean and free from dust at all times. Blocked venti-
lation slots can cause overheating and damage to the motor.  

Stay Alert  

Watch what you are doing, use common sense, and do not operate the air tool when you are 
tired or have taken medication that causes drowsiness, consumed alcohol or drugs.  

FOR ADDITIONAL PROTECTION FROM ELECTRIC SHOCK 

It is recommended that this tool be used in conjunction with a residual current device (RCD) 
with a rated residual current of 30mA or less. 
 

General Warnings for compressors

 

• 

 

Do not attempt to modify the compressor in any way.  

• 

The use of any tools or accessory other than those designed for use with compressed air 
could result in injury to the operator.  

• 

The output pressure of the compressor should be adjusted to the design pressure of the 
air tool or accessory being used.  

• 

Always check that the output of the compressor does not exceed the maximum pressure 
for any attached tool or accessory.  

• 

Repairs should only be carried out by qualified persons using original spare parts. Fail-
ure to do so may result in considerable danger to the user.  

Breathable Air Warning 

This compressor/pump is not equipped and should not be used  to supply breathing quality air 
for any application of air for human consumption. 

Overload protection

. This compressor is fitted with an overload protection device. In the event 

that the motor becomes too hot, a thermal protection device will cut the mains supply to the mo-
tor. When the motor temperature returns to normal the mains supply will be restored automati-
cally.  

Содержание RAAC2.5/36

Страница 1: ...ral instruction for installation use and maintenance Protect yourself and others by observing all safety information warnings and cautions Failure to comply with instructions could result in personal injury and or damage to product or property Please retain instructions for future reference ...

Страница 2: ...faulty materials and workmanship for 12 months from the date of purchase Please retain your receipt as proof of purchase If the product is found to be defective within the relevant time period we will either replace all defective parts or at our discretion replace the unit free of charge with the same item or items of a greater value and or specification This guarantee does not cover defects cause...

Страница 3: ...a risk of explosion or fire from combustible materials flammable liquids e g paint varnish petrol etc or flam mable gases and dust of an explosive nature Guard Against Electric Shock Do not expose your compressor to rain or use in damp or wet locations Beware Children and Pets Children and pets should be kept out of the work area Use the right tool Select the right tool for the job Do not use a to...

Страница 4: ... is recommended that this tool be used in conjunction with a residual current device RCD with a rated residual current of 30mA or less General Warnings for compressors Do not attempt to modify the compressor in any way The use of any tools or accessory other than those designed for use with compressed air could result in injury to the operator The output pressure of the compressor should be adjust...

Страница 5: ...d or repaired at an authorised service centre Check any other condition that may affect the operation of the com pressor A guard or any other part of the compressor that is damaged should be properly re paired or replaced by an authorised service centre Disconnect Compressor Ensure that the compressor is disconnected from the mains supply and the tank is empty when not in use before servicing lubr...

Страница 6: ...L VIEW AND MAIN COMPONENTS Main compressor Pressure switch Outlet Valve Regulating Valve Pressure gauge Non Return Valve Drain cock Wheel Discharge pipe Air tank Safety valve Fan cover 2 5HP 36L Note Fittings may differ from those shown above ...

Страница 7: ...t 2 Rubber stopper 3 Air Filter 4 Oil Breather plug 5 A bottle of oil Fit the wheels to the unit using the axle kit provided and insert the rubber stopper into the spigot on the bottom of the tank Fit the air filter to cylinder head of the compressor Locate the plastic dust plug in the oil filler hole and remove it to expose the oil filler hole 2HP 2 5HP Oil filler hole ...

Страница 8: ... the first 10 hrs of operation then every 20 hrs thereafter Recommend compressor oil Use SAE30 for temperatures over 10 and use SAE10 below 10 INITIAL STARTUP Ensure the unit is stable in a well ventilated dry posi tion Ensure that drain the valve is closed and air outlets are closed Connect the power lead to the mains Start the compressor by pulling on the red knob Check for air leaks Warning Use...

Страница 9: ...e that during use of the compressor the motor will cycle start and stop under the influence of the rising or falling pressure in the tank and the motor will start without any warning The maximum and minimum pressures are factory set and should not be altered You can utilise either the direct outlet and or the regulated outlet The pressure of the regulated outlet can be changed by turning the contr...

Страница 10: ...uired Caution ensure That air the tank is empty for this operation 2 Manually test the safety valve by pulling the ring Warning Before maintenance operation stop the air compressor disconnect the unit from the mains supply and discharge all air in the air tank Three Monthly 1 Change Oil 2 Tighten cylinder head bolts 3 Clean and check valve assembly replace gaskets valves if worn or damaged Recomme...

Страница 11: ...al noise Connecting part loosed Foreign body got into main compressor Piston knocking valve seat Moving parts seriously worn Check and retighten Check and clean away Replace with thicker paper gasket Repair or replace Pressure insufficient or discharge capacity decreased Motor running too slow Air filter choked up Leakage of safety valve Leakage of discharge pipe Sealing gasket damaged Valve plate...

Страница 12: ...RAAC2 24 and RAAC2 5 36 12 ...