![Ross M DM2 C Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/ross/m-dm2-c-series/m-dm2-c-series_manual_1488822005.webp)
F3.20
© 2016,
ROSS
CONTROLS
®
.
All Rights Reserved.
IMPORTANT NOTE:
Please read carefully and thoroughly all of the
CAUTIONS, WARNINGS
on the inside back cover.
Online Version
Rev. 11/14/16
DM
2®
Series C Double Valves, Manual Lockout L-O-X
®
Valves with Filter and Regulator
Custom designs available, consult ROSS.
Air Entry Packages
DM Series C Double Valves - Control Reliable Energy Isolation
RC Series
Pre-engineered panel-mounted design with air entry via a filter and regulator “FR”, or filter,
regulator and lubricator “FRL”
Includes DM
2®
Series C Double Valve with Monitoring & Memory:
a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Dynamic memory of abnormal function prevents unintentional reset with removal of air or electricity
All necessary features for safety applications are included:
a) Electrical reset valve,
b) Status indicator switch for valve condition (ready to run) feedback
4
Air Entry
Combination
Port Size
Model
Number
*
Air Entry
Type
C
V
Dimensions
inches (mm)
1, 2
3
1-2
2-3
Length
Width
Depth
Cat-4 with DM2
®
Series C
1/2
1/2
RC408-06
**
FR
3
10
24.0 (610) 14.5 (369)
7.4 (187)
Cat-4 with DM2
®
Series C
1/2
1/2
RC408L-06
**
FRL
4.4
13
24.0 (610) 15.7 (399)
8.3 (211)
Cat-4 with DM2
®
Series C
3/4
3/4
RC412-06
**
FR
4.4
13
27.0 (686) 19.0 (483)
9.0 (229)
Cat-4 with DM2
®
Series C
3/4
3/4
RC412L-06
**
FR
3
10
24.0 (610) 14.5 (369)
7.4 (187)
Cat-4 with DM2
®
Series C
1
1
RC416-06
**
FRL
4.4
13
24.0 (610) 15.7 (399)
8.3 (211)
Cat-4 with DM2
®
Series C
1
1
RC416L-06
**
FRL
4.4
13
31.0 (788) 19.0 (483)
9.0 (229)
*
NPT pressure port threads.
**
Specify voltage when ordering. Insert voltage code: “
W
” = 24 volts DC; “
Z
” = 110-120 volts AC, 50/60 Hz; e.g., RC408-06
W
.
M12 connectors available, consult ROSS.
Standard Air Entry Packages supplied with metal bowl and manual drain. For automatic drain insert an “
A
” before the dash
(-) in the model number, e.g., RC408
A
-06.
M
DM
2®
Series C Double Valves with Integrated Soft Start, Manual Lockout L-O-X
®
Valves
with Integrated Filter/Regulators
Pre-engineered panel mountable design with air entry via a filter and regulator “FR”, or filter,
regulator and lubricator “FRL”
Includes M DM
2®
Series C Double Valve with Monitoring & Memory:
a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Dynamic memory of abnormal function prevents unintentional reset with removal of air or electricity
All necessary features for safety applications are included:
a) Electrical reset valve,
b) Status indicator switch for valve condition (ready to run) feedback
M
5 1 1
X
A
2 1
2
1
1
HOW TO ORDER
(Choose your options (in red) to configure your valve assembly model number.)
PIPE SIZE
1/2 NPTF
4
3/4 NPTF
5
1/2 BSPP
D
3/4 BSPP
E
LOCKOUT VALVE TYPE
Modular L-O-X
®
1
L-O-X
®
2
No L-O-X
®
X
FILTER-REGULATOR
(0-125 psi with 0-200 gauge)
5 Micron, Manual Drain, Metal Bowl
1
5 Micron, Auto Drain, Metal Bow
2
None
X
LUBRICATOR
FILL TYPE
Fill Port
2
No lubricator
X
EXTRA PORTS
(Prior to M DM2
®
Exhaust Valve)
1/4
2
3/8
3
1/2
4
None
X
M DM2
®
VALVE
Without Transducer
1
With Transducer
3
EXTRA PORTS
(Downstream of M DM2
®
)
1/4
2
3/8
3
1/2
4
None
X
DOWNSTREAM PRESSURE SWITCH
(includes 1/4” Extra Port)
586A86
1
None
X
CABLE OPTIONS
Yes
1
No
X
4
Custom designs available, consult ROSS.
Explosion proof solenoid pilot available, for more information consult ROSS.
F
F3
NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT AS EMERGENCY STOP DEVICES.