background image

Installation (Iss. 05) • 10 

Installation

Static Discharge

Whenever handling the CMA-9011-R and other related equipment, please 
observe all static discharge precautions as described in the following note:

ESD Susceptibility

 — Static discharge can cause serious damage 

to sensitive semiconductor devices. Avoid handling circuit boards in 
high static environments, such as carpeted areas, and when wearing 
synthetic fiber clothing. Always exercise proper grounding precautions 
when working on circuit boards and related equipment.

Unpacking

Unpack each CMA-9011-R you received from the shipping container and check 
the contents to ensure that all items are included. If any items are missing or 
damaged, contact your sales representative or Ross Video directly.

Mounting and Installation

The CMA-9011-R can be mounted in any convenient location. However, to 
ensure long life for this product, observe the following precautions and 
operating requirements:

Maintain an ambient temperature of 20°C to 40°C.

Allow for air circulation around the chassis for convectional cooling.

Many different mounting positions are possible with the included mounting 
hardware. Some installation options are permanent and require careful 
consideration of the final positioning before installation. Please note that in 
some mounting locations, the power adapter must be affixed in a similar manner 
as the chassis.

Other possible options include the use of adhesive magnetic sheets (not 
included) affixed to the chassis and the power adapter, for removable mounting 
on metal cabinets etc.

Cable ties may be necessary in some applications to relieve strain on the 
mounting hardware and the connectors.

Surface Mount Strips

The included VELCRO® brand surface mount strips allow the GearLite module 
and power supply to be affixed to a permanent location during use and easily 

Содержание GearLite CMA-9011-R

Страница 1: ...CMA 9011 R SDI Component Monitoring Amplifier with Reclocked SDI Outputs User Manual...

Страница 2: ...people that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethi...

Страница 3: ...retrieval system or transmitted in any form or by any means mechanical photocopying recording or otherwise without the prior written permission of Ross Video While every precaution has been taken in t...

Страница 4: ...ervicing instructions within the Product Manual Documentation Failure to heed this information may present a major risk of damage or injury to persons or equipment Warning The symbol with the word War...

Страница 5: ...receptacles and point where they exit from the apparatus 7 Warning Indoor Use WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 8 Do not block venti...

Страница 6: ...the user will be required to correct the interference at his own expense Notice Changes or modifications to this equipment not expressly approved by Ross Video Limited could void the user s authority...

Страница 7: ...e extraction and use of natural resources for its production It may contain hazardous substances that could impact health and the environment To avoid the potential release of those substances into th...

Страница 8: ...7...

Страница 9: ...re monochrome output 75 color bar pattern and vertical interval blanking The CMA 9011 R provides conversion of 525 and 625 SDI signals SMPTE 259M NTSC PAL and PAL N standards are supported The CMA 901...

Страница 10: ...Four reclocked SDI outputs Reclocking to reduce jitter and noise Automatic input cable equalization 250m 820ft of Belden 8281 Color bar test signal with valid SDI input Excellent I O specifications Te...

Страница 11: ...venient location However to ensure long life for this product observe the following precautions and operating requirements Maintain an ambient temperature of 20 C to 40 C Allow for air circulation aro...

Страница 12: ...nstallation Option 3 Remove the Protective Backing Film from the other side of the VELCRO brand Surface Mount Strips 4 Press the chassis into position on the surface you want to mount it to Operating...

Страница 13: ...te onto the bottom of the chassis Figure 3 using the screws provided in the Mounting Kit Do not use the screws removed during Step 1 Figure 3 Flat Metal Plate Installation Option 3 Install the chassis...

Страница 14: ...13 Installation Iss 05 Figure 4 Angle Mounting Bracket...

Страница 15: ...Installations outside of North America using line voltages of 200 240V require a plug certified for the country of use to be installed on the supplied line cord Refer to the section Important Regulato...

Страница 16: ...rence guide Note SW1 7 and SW1 8 are not implemented and should be left in their default UP position Table 1 outlines how to set SW1 1 to SW1 6 and the following conventions are used Set the DIP switc...

Страница 17: ...s Indicator LEDs Table 2 Status LED Descriptions LED Color Function STATUS Green When lit green this LED indicates that the CMA 9011 R is powered on and functioning correctly Flashing Green When flash...

Страница 18: ...modated SMPTE 259M conversion at 270Mbps only Input Impedance 75ohm terminating Return Loss 19dB to 270MHz Equalization Automatic up to 26dB 250m of Belden 8281 cable 270Mbps Serial Video Output Numbe...

Страница 19: ...quency Response 0 25dB to 5MHz typically 1dB 5 75MHz Differential Phase 1 Differential Gain 1 Outputs Short Circuit Protected Yes RMS Noise unweighted 53dB 0 5MHz Power Required Voltage 5V DC 5 regula...

Страница 20: ...ser Manual of our Digital Products line provides all pertinent information for the safe installation and operation of your GearLite Product Ross Video policy dictates that all repairs to the GearLite...

Страница 21: ...Service Information Iss 05 20 Notes...

Страница 22: ...21 Service Information Iss 05 Notes...

Страница 23: ...Service Information Iss 05 22 Notes...

Страница 24: ...trade show information Visit Us Visit our website for Company information and news Related products and full product lines Online catalog Testimonials Technical Support Telephone 1 613 652 4886 After...

Отзывы: