background image

ASI-310 User Guide (v5.0)

Configuration • 23

Configuration

This chapter explains how to use the options in DashBoard to set up the ASI-310. This discussion is based on the 
use of DashBoard through a network connection. The order of sections in this chapter follows the work-flow 
required to setup the ASI-310 for operation. It is recommended that you proceed through the following sections in 
order to achieve the best possible understanding of the product. 

ASI-to-310 Converter Settings

The 

ASI to 310

 tab provides options for configuring the ASI-to-310 converter feature.

To set up the ASI-to-310 converter

1. Select the 

ASI to 310 

tab.

2. Use the 

310 Output Bit Rate

 options to set the output data rate.

3. Use the 

Output Packet Size

 options to specify the number of bytes per packet in the 310 output.

This is normally 188 bytes, but you can set it to 204 or 208 bytes if needed for your application. If the input 
packet size is different from the output size you specify, the converter adjusts the number of dummy 
error-correction bytes appended to the basic 188-byte payload to achieve the desired total packet length.

4. Configure the 

PCR Restamping

 option.

It should normally be left at the 

On

 setting, since this minimizes PCR error and jitter in the output. It does this 

by adjusting the PCR values to account for the slightly variable packet processing delays caused by adding or 
deleting null packets to maintain the specified output data rate and/or modify the packet size.

5. Set the 

310 Output Clock

 to either Free-running or Lock to 310 Input.

If you have a high-accuracy high-stability 310 signal available, you can connect it to the 310 Input jack, and set 
this variable to Lock to 310 Input. Otherwise, it should be set to Free-running which uses an accurate on-board 
frequency reference to generate the output data rate.

6. Use the 

310 Input Bit Rate

 to set the 310 reference input data rate. This must be set to the correct value if you 

have selected Lock to 310 Input as the 310 Output Clock setting, or if you are using the 310-to-ASI converter 
as discussed in the next section.

When the 310-to-ASI converter is active and its input is from the ASI-to-310 converter, it is essential that you set 
the 310 Output Clock to Free-running. If you set it to Lock to 310 Input, the converter would effectively lock its 
310 clock to itself, which would produce unspecified and possibly non-compliant output signals.. 

310-to-ASI Converter Settings

There are two modes for the 310-to-ASI converter:

Packet Mode

 — All the bytes of each TS packet are output consecutively, and fill characters (K28.5) are 

inserted between packets. When there are no bytes ready for transmission, K28.5 characters are transmitted.

Byte Mode

 — Each SMPTE 310 byte that arrives at the converter input is transmitted on the ASI output as soon 

as it is ready. The timing and packet size present in the 310 input are preserved exactly in the ASI output. 310 
Input Bit Rate sets the 310 input data rate to either 19.39 or 38.78Mbps. This must be set to the correct value if 
you are using the 310-to-ASI converter. This same variable is available on the 

ASI to 310 Settings

 tab, since this 

input can also be used as a frequency reference for the 310 output.

To set up the 310-to-ASI converter

1. Select the 

310 to ASI 

tab.

2. Use the 

Output Packet Size

 to adjust the number of bytes per packet in the ASI output. 

Содержание ASI-310

Страница 1: ...ASI 310 User Guide ...

Страница 2: ...people that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics hangs on the wall of all Ross Video locations to guide our behavior 1 We will always act in our customers best interest 2 We will do our best to understand our customers requirements 3 We will not s...

Страница 3: ...anual is furnished for informational use only It is subject to change without notice and should not be construed as commitment by Ross Video Limited Ross Video Limited assumes no responsibility or liability for errors or inaccuracies that may appear in this manual Safety Notices Refer to the Important Regulatory and Safety Notices document that accompanied your product Statement of Compliance This...

Страница 4: ...e International This equipment has been tested under the requirements of CISPR 22 2008 or CISPR 32 2015 and found to comply with the limits for a Class A Digital device Maintenance User Serviceable Parts Routine maintenance to this openGear product is not required This product contains no user serviceable parts If the module does not appear to be working properly please contact Technical Support u...

Страница 5: ...nvironmentally friendly and health conscious manner The crossed out wheeled bin symbol invites you to use these systems If you need more information on the collection reuse and recycling systems please contact your local or regional waste administration You can also contact Ross Video for more information on the environmental performances of our products Company Address Ross Video Limited Ross Vid...

Страница 6: ......

Страница 7: ...ng 13 Status and Selection LEDs on the ASI 310 14 Supported Rear Modules 15 MDL R10 Rear Module 15 MDL R20 Rear Module 16 Connections Overview 16 310 In BNC 1 16 ASI In BNC 4 or BNC 5 16 310 Out BNC 3 16 310 Monitor BNC 2 16 BNC 4 MDL R10 only 16 ASI Out BNC 5 or BNC 6 17 GPI O Outputs 17 Physical Installation 19 Before You Begin 19 Static Discharge 19 Unpacking 19 Quick Start 19 Installing the AS...

Страница 8: ...25 GPIO Status Tab 26 Alarm Counters Tab 26 Resetting the Alarm Counters 26 Loading the Factory Defaults 26 Upgrading the Software 27 Technical Specifications 29 Service Information 31 Troubleshooting Checklist 31 Warranty and Repair Policy 31 Glossary 33 ...

Страница 9: ...It is recommended to consult the following Ross documentation before installing and configuring your ASI 310 DashBoard User Guide Ross Part Number 8351DR 004 MFC OG3 N and MFC 8322 S User Guide Ross Part Number 8322DR 004 OGX FR Series Quick Start Guide Ross Part Number 8322DR 202 OGX FR Series User Guide Ross Part Number 8322DR 204 Documentation Conventions Special text formats are used in this g...

Страница 10: ...es you have access to technical expertise around the clock After sales service and technical support is provided directly by Ross Video personnel During business hours Eastern Time technical support personnel are available by telephone After hours and on weekends a direct emergency technical support phone line is available If the technical support person who is on call does not answer this line im...

Страница 11: ... PCR re stamping to correct timing errors caused by the insertion or deletion of null packets to achieve the desired 310M output bit rate The included 310 to ASI converter allows independent simultaneous conversions in both directions The combination of a second 310M output and the 310 to ASI converter allows in service monitoring of the 310M output with ASI based equipment such as the Ross Video ...

Страница 12: ...on on the ASI 310 menus in DashBoard refer to the chapter Configuration on page 23 using DashBoard refer to the DashBoard User Guide available from our website SNMP Monitoring and Control The Network Controller Card in the openGear frame provides optional support for remote monitoring of your frame and the using Simple Network Management Protocol SNMP which is compatible with many third party moni...

Страница 13: ...l connectors Main PCB Overview The main PCB is a typical openGear card An ejector on one end secures the module to the slot inside the openGear frame and the other end inserts into a connector on the back of the rear module This section provides a general overview of the ASI 310 card edge components Figure 1 1 ASI 310 Reset Button Reset Button SW3 This button is used for rebooting the card Control...

Страница 14: ... indicates that the card is not operational This will occur if for example there is no video input It also lights red when the OSD is enabled Off When unlit this LED indicates there is no power DS2 This LED is not implemented DS3 This LED is not implemented DS4 This LED is not implemented ASI IN DS5 Green When lit green this LED indicates the ASI input is present and valid Red When red or flashing...

Страница 15: ...es that the rear module connected to the ASI 310 is not suitable for use with the ASI 310 Operation will not be correct Video Error DS8 Green When lit green this LED indicates the video is supported by the card Red When lit red this LED indicates that the signal connected to the video input is a known type but is not ASI for example it could be SDI or HD SDI Operation will not be correct DS9 This ...

Страница 16: ...utput The input signal is internally terminated in 75ohms when the ASI 310 is installed When the ASI 310 is removed from the rear module this input is terminated in the equipment connected to the 310 Out BNC ASI In BNC 4 or BNC 5 BNC 4 BNC 5 on the MDL R10 accepts an ASI Transport Stream input for conversion to SMPTE 310M The input signal is internally terminated in 75ohms when the ASI 310 is inst...

Страница 17: ...h level is 3 3V and the low level is 0V Each output is suitable for driving a logic circuit or LED through a short cable If you need to drive high current or high voltage loads or loads that are referenced to a different ground that the ASI 310 card use an external relay circuit between the GPI O pin s and the load Refer to Figure 1 5 for pinouts on the MDL R10 and Figure 1 6 for pinouts on the MD...

Страница 18: ...18 Hardware Overview ASI 310 User Guide v5 0 ...

Страница 19: ...rame as described in the section Installing a Rear Module on page 20 4 Install the ASI 310 into the rear module as described in the section Installing the ASI 310 in an openGear Frame Slot on page 21 5 Connect an ASI signal to the ASI IN BNC on the rear module as described in the section Connections Overview on page 16 6 Connect the 310 Out BNC to an appropriate analyzer or other downstream equipm...

Страница 20: ...le is required Installing a Rear Module If the Rear Module is installed proceed to the section Installing the ASI 310 in an openGear Frame Slot on page 21 To install a rear module in your openGear frame 1 Locate the card frame slots on the rear of the frame 2 Remove the Blank Plate from the slot you have chosen for the ASI 310 installation 3 Install the bottom of the Rear Module in the Module Seat...

Страница 21: ...e frame until the rear connection plus is properly seated in the Rear Module 4 Verify whether your label is self adhesive by checking the back of the label for a thin wax sheet You must remove this wax sheet before affixing the label 5 Affix the supplied Rear Module Label to the BNC area of the Rear Module Notice Heat and power distribution requirements within a frame may dictate specific slot pla...

Страница 22: ...22 Physical Installation ASI 310 User Guide v5 0 ...

Страница 23: ...stability 310 signal available you can connect it to the 310 Input jack and set this variable to Lock to 310 Input Otherwise it should be set to Free running which uses an accurate on board frequency reference to generate the output data rate 6 Use the 310 Input Bit Rate to set the 310 reference input data rate This must be set to the correct value if you have selected Lock to 310 Input as the 310...

Страница 24: ...t 4 To apply the new settings a Click Accept b Click Yes String Settings The Edit Strings tab allows you to assign a name to this ASI 310 card to distinguish it in DashBoard from other cards of the same type It also lets you assign descriptive names to the GPI O outputs To configure a string 1 Select the Edit Strings tab 2 Enter a unique name in the Card ID field For example you could change the c...

Страница 25: ...d by the selections made on the Alarms setup tab Card Status Any error conditions that are enabled on the Alarms setup tab are reported in the Card Status field red indicator when they occur Alarm conditions that are disabled the corresponding box in the Alarms setup tab is unselected are not reported in the Card Status field Incoming ASI This field reports the speed and the packet size of the ASI...

Страница 26: ...t the number of times that the Alarm condition has occurred since the last time the counters were reset Since the GPI Os are associated with error conditions the Alarm Counters tab provides a record of the number and types of errors that have occurred over time You can clear these counters by clicking the Alarm Counters Reset button located on the Settings tab Resetting the Alarm Counters The Sett...

Страница 27: ... Upload to display the Select File for upload dialog 5 Navigate to the bin upload file you wish to upload 6 Click Open and follow the on screen instructions 7 Click Finish to start the upgrade 8 Monitor the upgrade A Upload Status dialog enables you to monitor the upgrade process The card reboots automatically once the file is uploaded The card is temporarily taken off line The reboot process is c...

Страница 28: ...28 Upgrading the Software ASI 310 User Guide v5 0 ...

Страница 29: ... 1 input SMPTE 310 Impedance 75ohm terminating Equalization Over 150m 500ft of Belden 1694A cable Return Loss 15dB to 270MHz Transport Stream Outputs Number of Outputs 3 Signal Standards Accommodated 2 outputs SMPTE 310 1 output DVB ASI dual purpose with 259M OSD Impedance 75ohm Return Loss 10dB to 270MHz Signal Level 800mV 10 DC Offset 0Volts 50mV Rise and Fall Time 20 80 750ps typical Overshoot ...

Страница 30: ...30 Technical Specifications ASI 310 User Guide v5 0 ...

Страница 31: ...ividual units Warranty and Repair Policy The ASI 310 is warranted to be free of any defect with respect to performance quality reliability and workmanship for a period of FIVE 5 years from the date of shipment from our factory In the event that your ASI 310 proves to be defective in any way during this warranty period Ross Video Limited reserves the right to repair or replace this piece of equipme...

Страница 32: ... the responsibility of you the customer All products shipped to you from Ross Video Limited will be shipped collect The Ross Video Technical Support Department will continue to provide advice on any product manufactured by Ross Video Limited beyond the warranty period without charge for the life of the equipment ...

Страница 33: ...a essence not metadata For convenience this manual uses the term metadata to refer to all VANC data types MIB management information base Network Controller Card the MFC OG3 N and any available options unless otherwise noted NTSC captions the CEA 608 D Line 21 Data Services captions openGear frame refers to the OGX FR series frames unless otherwise noted PAL PAL B and PAL G unless otherwise stated...

Страница 34: ...34 Glossary ASI 310 User Guide v5 0 ...

Отзывы: