2.
Use the
SET
knob to select the amount of delay you want to assign to screener 2. (0:01 to Total PGM
Delay)
The maximum amount of time available depends on the model of AirCleaner
®
you have and the
video format you are working in. The higher the format, the less time is available.
Video Reaction Times
The Video Reaction selects the reaction time delay for a screener when the Video Panic Button for that
screener is pressed. In a two-screener system there are separate reaction times for both screeners. This
will back-time the button press to compensate for the time it takes the screener to see a violation and
then press the VIDEO panic button.
To Set the Video Reaction Time
This allows the system to compensate for the amount of time it takes for a screener to see a violation
and press the panic button. The inpoint for the violation is set back this amount to compensate for the
reaction time.
1.
Use the
SELECT
button to select the video reaction you want to set.
•
Video Reaction 1
— the video reaction offset for screener 1.
•
Video Reaction 2
— the video reaction offset for screener 2. (Screeners must be set to TWO)
2.
Use the
SET
knob to select the amount of reaction time in seconds. (0 to max)
The maximum amount of time available depends on the model of AirCleaner
®
you have and the
video format you are working in. The higher the format, the less time is available.
Tip:
Although it may be tempting to program an extremely large reaction time, there are pitfalls of doing so. A very large reaction
time can cause the violation trigger to be advance so far ahead of the actual violation that a large amount of non-violation content
will be lost.
Audio Reaction Times
The Audio Reaction selects the reaction time delay for a screener when the Audio Panic Button for that
screener is pressed. In a two-screener system there are separate reaction times for both screeners. This
will back-time the button press to compensate for the time it takes the screener to hear a violation and
then press the Audio panic button.
To Set the Audio Reaction Time
This allows the system to compensate for the amount of time it takes for a screener to hear a violation
and press the panic button. The inpoint for the violation is set back this amount to compensate for the
reaction time.
1.
Use the
SELECT
button to select the audio reaction you want to set.
•
Audio Reaction 1
— the audio reaction offset for screener 1.
•
Audio Reaction 2
— the audio reaction offset for screener 2. (Screeners must be set to TWO)
2.
Use the
SET
knob to select the amount of reaction time in seconds. (0 to max)
The maximum amount of time available depends on the model of AirCleaner
®
you have and the
video format you are working in. The higher the format, the less time is available.
Tip:
Although it may be tempting to program an extremely large reaction time, there are pitfalls of doing so. A very large reaction
time can cause the violation trigger to be advance so far ahead of the actual violation that a large amount of non-violation content
will be lost.
26 • Delays and Offsets — AirCleaner-2 User Manual (v01)